Empowering Biopolis, Tuas Biomedical Park, Jurong Innovation District, and academic powerhouses with advanced aerodynamic sizing and exposure instrumentation.
As Southeast Asia's epicentre for biomedical research, advanced semiconductor fabrication, and stringent environmental governance, Singapore demands unparalleled precision in aerosol science. Beijing Huironghe Technology Co., Ltd. delivers state-of-the-art Aerosol Particle Sizer (APS) systems and specialized inhalation exposure suites engineered to meet the strictest Good Laboratory Practice (GLP), ISO 14644 cleanroom, and international pharmacopeia standards.
From characterising Dry Powder Inhaler (DPI) plumes at the Agency for Science, Technology and Research (A*STAR) facilities to continuous monitoring of submicron particulate matter in cleanrooms across Woodlands and Tampines wafer fabs, accurate measurement of aerodynamic particle diameter ($0.5\,\mu\text{m}$ to $20\,\mu\text{m}$) is critical to product yield, efficacy, and biosafety.
Equipped with dual-laser time-of-flight (TOF) velocimetry, real-time light scattering sensors, and automated mass-concentration algorithms, our instruments empower Singaporean researchers to resolve bimodal aerosol distributions with sub-second temporal resolution, ensuring full compliance with HSA and international regulatory frameworks.
Accelerating inhalation drug discovery, Metered Dose Inhaler (MDI) aerosolization profiling, and aerodynamic mass median diameter (MMAD) determination for global pharmaceutical titans operating in Singapore.
Delivering aerosol photometers and condensation particle monitoring for ISO Class 1 to Class 5 cleanrooms in Singapore's precision wafer manufacturing plants and microelectronics hubs.
Supporting National Environment Agency (NEA) research initiatives, real-time PM2.5/PM10 fraction discrimination, and urban bioaerosol tracking across Singapore's tropical microclimate.
These integrated solutions are widely employed by Singapore GLP laboratories, biomedical safety assessment centers, academic institutes (NUS, NTU, SUTD), and hospital respiratory departments.

Nose-only exposure systems are the primary method for acute and chronic inhalation toxicology assessments in compliance with OECD 412/413 guidelines in Singapore preclinical centers.

Inhalers are the preferred route of administration for respiratory diseases such as asthma and chronic obstructive pulmonary disease (COPD), evaluated via Next Generation Impactors (NGI).

Beijing Huironghe Technology Co., Ltd. provides comprehensive aerosol generation and particle sizing solutions for complex liquid droplets and dry solid powder samples.

From SARS to COVID-19, supporting specialized biodefense and pathogenic microorganism aerosol infection animal models within BSL-3 and ABSL-3 containment facilities in Singapore.

The QuEChERS method for pesticide residue sample preparation is widely used across Singapore Food Agency (SFA) certified food safety screening and analytical labs.
Understanding time-of-flight technology, dynamic shape factor corrections, and optical scattering correlation.
An Aerosol Particle Sizer (APS) operates on the fundamental physical principle of accelerating aerosolized particles through an accelerating nozzle and calculating individual time-of-flight (TOF) across dual high-speed laser beams. Unlike geometric optical sizing or electrical mobility sizing (which measures equivalent mobility diameter), aerodynamic diameter directly reflects how aerosol particles behave in airflows, human airways, filtration media, and environmental plumes.
1. Accelerating Nozzle Flow: Sample air is drawn through an aerodynamic converging nozzle where the surrounding sheath air forces particles to accelerate. Due to particle inertia, heavier particles with larger aerodynamic diameters accelerate more slowly than smaller particles.
2. Dual-Beam Laser Velocimetry: As particles traverse two closely spaced split-laser beams ($0.5\,\text{mm}$ beam separation), two distinct scattered light pulses are captured by a high-gain avalanche photodetector. The elapsed time between pulses is directly converted to aerodynamic diameter ($d_{ae}$).
3. Integrated Light Scattering Intensity: Simultaneously, the optical scattering intensity is recorded for each particle, enabling simultaneous determination of aerodynamic diameter and optical diameter, revealing invaluable morphological insights regarding particle density and dynamic shape factor ($\chi$).
| Parameter / Specification | Aerodynamic Particle Sizer (APS Series) | Aerosol Photometer (Cleanroom Series) | Dust Aerosol Generator (Solid Dust) |
|---|---|---|---|
| Measurement Range | $0.5\,\mu\text{m} - 20\,\mu\text{m}$ (Aerodynamic Size) | $0.0001\,\mu\text{g}/\text{L} - 600\,\mu\text{g}/\text{L}$ | $0.1\,\mu\text{m} - 100\,\mu\text{m}$ (Dispersible) |
| Size Channels / Resolution | Up to 52 high-resolution channels | Logarithmic dynamic photometric detection | Adjustable feed velocity & turntable RPM |
| Sampling Flow Rate | $5.0\,\text{L/min}$ total ($1.0\,\text{L/min}$ aerosol, $4.0\,\text{L/min}$ sheath) | $28.3\,\text{L/min}$ ($1.0\,\text{CFM}$) standard | $1.0 - 5.0\,\text{m}^3/\text{h}$ adjustable flow |
| Singapore Compliance | USP <601>, Ph.Eur. 2.9.18, ISO 27891 | ISO 14644-3, EN 1822, IEST-RP-CC001 | OECD TG 412/413, ISO 16890, EN 779 |
| Data Interfaces | RS485 / USB / Ethernet / Modbus / 21 CFR Part 11 | Thermal Printer / Touchscreen / USB Data Export | PLC Touch Controller / External Trigger Port |
Targeted solutions designed for Singapore's specialized industrial and scientific ecosystems.
In Biopolis pharmaceutical labs, our systems test dry powder carrier formulations (lactose monohydrate blending), measuring fine particle fraction (FPF) and fine particle dose (FPD) to optimize lung deposition in pulmonary therapeutics.
Supplied to semiconductor wafer fabs in Pasir Ris and Jurong, our aerosol photometers and aerosol generators allow rapid upstream/downstream concentration scanning for leak verification in ULPA/HEPA filtration banks.
Equipping GLP-certified Contract Research Organizations (CROs) in Tuas Biomedical Park with nose-only inhalation exposure towers and online particle sizers for non-clinical toxicology under OECD GLP conditions.
Comprehensive instrumentation portfolio engineered by Beijing Huironghe Technology Co., Ltd. for Singapore research labs.
Pioneering smart-sensing, bioaerosol vigilance, and green technology alignment.
Under Singapore's Smart Nation initiatives, aerosol particle sizing is rapidly migrating toward cloud-connected sensor matrices. Modern aerodynamic sizers are now integrated with artificial intelligence algorithms to predict particle agglomeration dynamics, simulate respiratory tract deposition curves, and automatically adjust sheath air flows to compensate for fluctuating ambient tropical humidity.
With Singapore intensifying environmental surveillance around coastal reclamation zones and urban waterways, aerodynamic sizing down to the sub-micron boundary is paramount. Researchers are combining our aerosol diffusion dryers and aerodynamic sizers to isolate, dry, and characterize airborne microplastics and engineered nanoparticles.
Post-pandemic vigilance has spurred significant investments by DSO National Laboratories and Duke-NUS Medical School. Advanced nose-only inhalation exposure systems and liquid aerosol generators enable precise generation of monodisperse viral/bacterial aerosols to evaluate antiviral countermeasures, personal protective equipment (PPE), and air sterilization systems under rigorous ABSL-3 containment.
The Singapore Standard SS 554 for Indoor Air Quality (IAQ) requires stringent monitoring of fine particulate matter ($PM_{2.5}$). Our particle counters and aerodynamic sizers provide baseline reference validation for high-efficiency air handling units (AHU) across BCA Green Mark Platinum certified commercial buildings.
Built for seamless validation under HSA, US FDA, EMA, and ISO quality frameworks.
Our rodent, canine, and non-human primate nose-only inhalation chambers feature uniform aerosol concentration gradients ($\text{RSD} < 5\%$), real-time oxygen/CO2 monitoring, and complete temperature/humidity regulation for non-clinical toxicology validation.
Our Multi-Stage Cascade Impactors (NGI) and breathing simulators fully adhere to United States Pharmacopeia USP <601> and European Pharmacopoeia Ph.Eur. 2.9.18 for aerodynamic particle size distribution (APSD) in metered-dose inhalers.
Our integrated instrument software includes full multi-tier user authority administration, electronic signatures, time-stamped audit trails, and encrypted SQL databases, ensuring effortless audit readiness for HSA and US FDA inspections.
Explore our core series of high-precision aerosol generators, aerodynamic sizers, photometers, and particle counters.
Comprehensive technical consultation, custom exposure duct design, and lifecycle calibration support.
Beijing Huironghe Technology Co., Ltd. serves as an internationally recognized leader in specialized aerosol science equipment and toxicology instrumentation. With dedicated engineering teams and rigorous ISO 9001 certified manufacturing facilities, we deliver fully customized aerosol delivery pathways, specialized nose-only adapters, and turnkey inhalation chambers designed specifically for cleanroom and laboratory space constraints in Singapore.
We work in close cooperation with Singaporean procurement managers, lab directors, and principal investigators to provide comprehensive Installation Qualification and Operational Qualification (IQ/OQ) protocols, on-site calibration, and rapid spare-parts delivery.