Biosafety Nose-only Exposure System for Non-human Primates - China Suppliers and Factory for ABSL-3 and ABSL-4 Labs
Features
Perform inhalation exposure tests for 3 monkeys simultaneously.
Class III BSC cabinet: compact design in stainless steel, excellent corrosion resistance, large round corners design is easy to clean. Double-sided design allows multi-users to operate together.
Integrated safety design: integrated design of Class III BSC cabinet and exposure tower mainly includes safety program coordinated control, sterilization and purification program settings, corrosion-resistant sensors, double HEPA filtration, intelligent pressure difference control, internal and external interlock, startup self-test, etc.
Negative pressure inside cabinet is not less than 120Pa, and mask pressure is not less than 100Pa.
Exhaust HEPA filter is Class H14 with leakage detection and sterilization in place.
HMI has functions of parameter settings, real-time display and data recording, etc. Real-time monitor parameters of oxygen concentration, carbon dioxide concentration, temp, humidity, pressure (between cabinet and HEPA filter), and abnormal alarms.
One-to-one control of monkey mouth and nose inhalation, enhances dose stability, accuracy and reproducibility.
Translucent aerosol generator enables visual monitoring of liquid level and atomization. Liquid samples can be added midway without downtime.
Monkey chair fits 3-6kg monkeys with adjustable sitting angle which makes monkey feel better.
The seat and back of the monkey chair are made of PTFE for comfort. A removable waste collector is located underneath the seat panel.
Monkeys can be quickly bound by velcro tape, which is convenient and reliable.
Application
Applicable to inhalation exposure tests of inhalation poisoning, inhalation immunity, R&D of inhalation formulations in ABSL-3, ABSL-4 laboratories.
Working Principle
The Biosafety Nose-only Exposure System for Non-human Primates is nose-only aerosol inhalation infection equipment for rodents combined with high-level biosafety protection. Key components are nose-only exposure system and Class III BSC cabinet. Applicable to nose-only exposure tests for rodents (e.g., mice, rats, guinea pigs, ferrets, rabbits, etc.) with same dose under non-anesthesia conditions. Meanwhile, Class III BSC cabinet keeps personnel, laboratory and environment safe during virulent pathogens tests.
Airflow Direction
Specification
Dimensions: Class III BSC cabinet less than 3100*900*2250mm (Working area: 1794*835*900mm).
Monkey Chair Angle: Adjustable up to 90°.
Extraction & Sampling Flow: 1-30L/min (adjustable).
Monkey Chair Size: 340*300*600 mm.
Negative Pressure (Cabinet): Not less than 120Pa.
Face Mask Pressure: Not less than 100Pa.
Aerosol Generation Flow: More than 0.2 mL/min.
Capacity: Perform inhalation test for 3 monkeys.
Microbial Aerosol Error: Stability and evenness error less than 20%.
Standards
RB∕T 199-2015 Technical code for evaluating biosafety performance of laboratory equipment
OECD TG 403 Acute Inhalation Toxicity (2009)
OECD TG 436 Acute Inhalation Toxicity. Acute Toxic Class Method (2009)
OECD TG 412 28d Sub-acute inhalation (2018)
OECD TG 413 90d Sub-chronic inhalation (2018)
Frequently Asked Questions
Q: How many monkeys can be tested simultaneously with this system?
A: The system is designed to perform inhalation exposure tests for up to 3 monkeys simultaneously.
Q: What are the pressure requirements inside the cabinet and mask?
A: The negative pressure inside the cabinet is kept at not less than 120Pa, and the face mask pressure is kept at not less than 100Pa.
Q: Can liquid samples be added during testing without system downtime?
A: Yes. The translucent aerosol generator allows you to visually monitor the liquid level and atomization, and liquid samples can be added midway without shutting down the system.
Q: What weight range and features does the monkey chair support?
A: The monkey chair fits monkeys weighing 3-6kg. It features an adjustable sitting angle of 90 degrees, is made of PTFE for comfort, and includes a removable waste collector underneath the seat panel.
Q: Which international testing standards does the system comply with?
A: The system complies with RB∕T 199-2015, OECD TG 403 (Acute Inhalation Toxicity), OECD TG 436 (Acute Toxic Class Method), OECD TG 412 (28d Sub-acute inhalation), and OECD TG 413 (90d Sub-chronic inhalation).
Q: What parameters are monitored in real-time by the HMI?
A: The HMI monitors, displays, and records oxygen concentration, carbon dioxide concentration, temperature, humidity, pressure difference (between the cabinet and the HEPA filter), and handles abnormal alarms.