Request a Quote
Leave Your Message

Biosafety Nose-only Exposure System for Rodents - China Suppliers and Factory-Grade Equipment for Safe Testing

The Biosafety Nose-only Exposure System for Rodents is a state-of-the-art solution for conducting nose-only aerosol inhalation tests on rodents, including mice, rats, guinea pigs, ferrets, and rabbits, without the need for anesthesia. This innovative equipment combines high-level biosafety with essential components such as the nose-only exposure system and a Class III Biological Safety Cabinet (BSC). Designed to meet the rigorous standards of safety, the Class III BSC cabinet ensures the protection of personnel, the laboratory environment, and the surrounding community during experiments involving virulent pathogens. As a leading supplier and factory based in China, we are dedicated to providing cutting-edge biosafety solutions for rodent testing, ensuring optimal safety and reliability for researchers and laboratories worldwide

    Features

    Animal adaptability: mice, rats, guinea pigs, ferrets, rabbits etc.

    Exposure environment monitoring: exposure room temp, humidity, pressure difference, carbon dioxide concentration, and oxygen concentration can be monitored in real-time during tests, compliant with the requirements of inhalation guidelines.

    Parameters real-time monitoring: aerosol generation flow rate, dilution flow rate, sampling flow rate, pumping flow rate, poisoning time, remaining time, etc.

    High-precision controller: Adopt a high-precision gas mass flow controller, which fully meets the requirements of gas flow accuracy in inhalation exposure tests.

    Class III BSC cabinet: compact design in stainless steel, excellent corrosion resistance, large rounded corners ensure no cleaning of dead corners. Double-sided design allows multi-users to operate together.

    Integrated safety design: integrated design of the Class III BSC cabinet and exposure tower mainly includes safety program coordinated control, sterilization and purification program setting, corrosion-resistant sensors, double HEPA filtration, intelligent pressure difference control, internal and external interlock, startup self-test, etc.

    Advanced technology platform: simulate natural infection of respiratory pathogen, provide an advanced evaluation platform for pathogenic microorganism inhalation infection, vaccine aerosol immunity, lung drug delivery and aerosol challenge evaluation for vaccine or drug.

    Nose-only inhalation infection: avoid other exposure pathways such as digestive tract and skin, which conform to the natural infection pathway of respiratory pathogens.

    Concentration uniformity and stability: adopt orthogonal dilution patented technology (CN201310351052.9), and consider hydrodynamics and other key parameters comprehensively to ensure microbial concentration is stable and uniformly distributed. The stability and uniformity of microbial aerosol deviation is less than ±20%.

    Software function: equipped with functions of user classified management, audit trail, data unerasable, etc., which meet requirements of GLP laboratories. It can carry out parameter settings, real-time monitoring and environmental parameters recording during tests, as well as real-time alarms and recording of abnormalities.

    Test data output: all experimental data can be stored and accessed, and reports can be issued automatically after test.

    Application

    Exposure tests of inhalation infection, inhalation immunity, inhaler R&D in ABSL-3 and ABSL-4 laboratories.

    Working Principle

    The Biosafety Nose-only Exposure System for Rodents mainly consists of bioaerosol generator, monkey chair, dedicated negative pressure cabinet for aerosol infections, multifunctional exposure mask, exposure environmental detection and control system, host controller, gas controller, bioaerosol sampler, aerosol mass concentration detector, bioaerosol waste gas treatment system, and protection alarm system. The negative pressure environment is kept through Class III BSC cabinet, which is isolated from laboratory by means of inlet HEPA filter and double HEPA filtration, airflow direction is shown in the figure.

    Specification

    Parameter Specification Details
    Dimensions of Class III BSC cabinet 2400*900*2100mm
    Dimensions of Class III BSC cabinet working area 1794*835*900mm
    Operation sides of Class III BSC cabinet Double-sided
    Filter precision H14/99.99%
    Noise Lower than 60db
    Exposure ports of 2 layers exposure tower 24 ports
    Flow rate of 3-hole aerosol generator 6L/min
    Particle size of liquid aerosol MMAD1-3μm, GSD:1.5-3
    Humidity of exposure chamber during test 30-70%RH
    Oxygen concentration in exposure chamber 19-21%
    Carbon dioxide concentration in exposure chamber Less than 1%

    Liquid Aerosol Generator

    Model Nozzle Number Rated Flow L/min Normal Operating Flow Range L/min
    HRH-WAG1 1 2 1-2
    HRH-WAG3 3 6 3-6
    HRH-WAG6 6 12 6-12
    HRH-WAG12 12 24 12-24
    HRH-WAG24 24 48 24-48

    Standards

    • RB∕T 199-2015 Technical code for evaluating biosafety performance of laboratory equipment
    • OECD TG 403 Acute Inhalation Toxicity (2009)
    • OECD TG 436 Acute Inhalation Toxicity. Acute Toxic Class Method (2009)
    • OECD TG 412 28d Sub-acute inhalation (2018)
    • OECD TG 413 90d Sub-chronic inhalation (2018)

    Frequently Asked Questions

    What types of animals are compatible with this nose-only exposure system?

    The system is designed for high adaptability with various laboratory animals, including mice, rats, guinea pigs, ferrets, rabbits, and other similar species.

    Which environmental parameters does the system monitor in real-time?

    It monitors exposure room temperature, humidity, pressure difference, carbon dioxide concentration, and oxygen concentration in real-time to fully comply with inhalation guidelines.

    How does the system guarantee biosafety during pathogenic exposure tests?

    Biosafety is maintained via an integrated Class III BSC cabinet under negative pressure, double HEPA filtration, intelligent pressure difference control, corrosion-resistant sensors, and internal/external interlocks.

    What is the stability and uniformity of the aerosol concentration?

    By using patented orthogonal dilution technology (CN201310351052.9) and optimizing hydrodynamics, the system ensures that microbial aerosol deviation is kept to less than ±20%.

    Is the system software compliant with GLP laboratory standards?

    Yes, the software features user classified management, audit trails, and unerasable data storage, ensuring full compliance with GLP laboratory requirements.

    Make An AppointmentLEAVE YOUR MESSAGE