Request a Quote
Leave Your Message

Biosafety Nose-only Exposure System for Rodents

The Biosafety Nose-only Exposure System for Rodents is nose-only aerosol inhalation infection equipment for rodents combined with high-level biosafety protection. Key components are nose-only exposure system and Class III BSC cabinet. Applicable to nose-only exposure tests for rodents (e.g., mice, rats, guinea pigs, ferrets, rabbits, etc.) with same dose under non-anesthesia conditions. Meanwhile, Class III BSC cabinet keeps personnel, laboratory and environment safe during virulent pathogens tests.

    Features

    1.Animal adaptability: mice, rats, guinea pigs, ferrets, rabbits etc.
    2.Exposure environment monitoring: exposure room temp, humidity, pressure difference, carbon dioxide concentration, and oxygen concentration can be monitored in real-time during tests, compliant with the requirements of inhalation guidelines.
    3.Parameters real-time monitoring: aerosol generation flow rate, dilution flow rate, sampling flow rate, pumping flow rate, poisoning time, remaining time, etc.
    4.Adopt a high-precision gas mass flow controller, which fully meets the requirements of gas flow accuracy in inhalation exposure tests.
    5.Class III BSC cabinet: compact design in stainless steel, excellent corrosion resistance, large rounded corners ensure no cleaning of dead corners. Double-sided design allows multi-users to operate together.
    6.Integrated safety design: integrated design of the Class III BSC cabinet and exposure tower mainly includes safety program coordinated control, sterilization and purification program setting, corrosion-resistant sensors, double HEPA filtration, intelligent pressure difference control, internal and external interlock, startup self-test, etc.
    7.Advanced technology platform: simulate natural infection of respiratory pathogen, provide an advanced evaluation platform for pathogenic microorganism inhalation infection, vaccine aerosol immunity, lung drug delivery and aerosol challenge evaluation for vaccine or drug.
    8.Nose-only inhalation infection: avoid other exposure pathways such as digestive tract and skin, which conform to the natural infection pathway of respiratory pathogens.
    9.Concentration uniformity and stability: adopt orthogonal dilution patented technology (CN201310351052.9), and consider hydrodynamics and other key parameters comprehensively to ensure microbial concentration is stable and uniformly distributed. The stability and uniformity of microbial aerosol deviation is less than ±20%.
    10.Software function: equipped with functions of user classified management, audit trail, data unerasable, etc., which meet requirements of GLP laboratories. It can carry out parameter settings, real-time monitoring and environmental parameters recording during tests, as well as real-time alarms and recording of abnormalities.
    11.Test data output: all experimental data can be stored and accessed, and reports can be issued automatically after test.

    Application

    Exposure tests of inhalation infection, inhalation immunity, inhaler R&D in ABSL-3 and ABSL-4 laboratories.

    Working Principle

    The Biosafety Nose-only Exposure System for Rodents mainly consists of bioaerosol generator, monkey chair, dedicated negative pressure cabinet for aerosol infections, multifunctional exposure mask, exposure environmental detection and control system, host controller, gas controller, bioaerosol sampler, aerosol mass concentration detector, bioaerosol waste gas treatment system, and protection alarm system. The negative pressure environment is kept through Class III BSC cabinet, which is isolated from laboratory by means of inlet HEPA filter and double HEPA filtration, airflow direction is shown in the figure.Working Principle1

    Working Principle

    Airflow Direction

    Exposure Tower for Rodents

    Exposure Tower for Rodents

    Specification

    Dimensions of Class III BSC cabinet

    2400*900*2100mm

    Dimensions of Class III BSC cabinet working area

    1794*835*900mm

    Operation sides of Class III BSC cabinet

    Double-sided

    Filter precision

    H14/99.99%

    Noise

    Lower than 60db

    Exposure ports of 2 layers exposure tower

    24 ports

    Flow rate of 3-hole aerosol generator

    6L/min

    Particle size of liquid aerosol

    MMAD1-3m, GSD:1.5-3

    Humidity of exposure chamber during test

    30-70%RH

    Oxygen concentration in exposure chamber

    19-21%

    Carbon dioxide concentration in exposure chamber

    Less than 1%

    Liquid Aerosol Generator

    Model

    Nozzle Number

    Rated Flow L/min

    Normal Operating Flow Range L/min

    HRH-WAG1

    1

    2

    1-2

    HRH-WAG3

    3

    6

    3-6

    HRH-WAG6

    6

    12

    6-12

    HRH-WAG12

    12

    24

    12-24

    HRH-WAG24

    24

    48

    24-48

    Standards

    RB∕T 199-2015 Technical code for evaluating biosafety performance of laboratory equipment

    OECD TG 403 Acute Inhalation Toxicity (2009)

    OECD TG 436 Acute Inhalation Toxicity. Acute Toxic Class Method (2009)

    OECD TG 412 28d Sub-acute inhalation (2018)

    OECD TG 413 90d Sub-chronic inhalation (2018)

    OECD FDA GLP

    Typical Users

    PLA Unit 32734

    National Institutes for Food and Drug Control

    Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences The First Affiliated Hospital of Nanchang University

    Chemical Defense Institute, Academy of Military Sciences, PLA

    WUHAN INSTITUTE OF BIOLOGICAL PRODUCTS CO.,LTD.

    PLA Army Chemical Defense College

    Military Veterinary Institute, Academy of Military Medical Sciences, Academy of Military Sciences, PLA

    Guangzhou Customs Technology Center

    The Fifth Medical Center of the PLA General Hospital

    Make An AppointmentLEAVE YOUR MESSAGE