Breathing Simulator HRH-BRM2100 for Nebulizer Testing - Reliable China Suppliers & Factory
Features
- USP, Ph. Eur. and ChP 2020 compliant.
- Tidal volume setting range is 0-1000ml.
- Built-in parameters for four standard respiratory modes specified in Pharmacopoeia including standard adult, standard child, standard infant and standard neonate.
- User-defined parameters: tidal volume, respiratory rate, I/E ratio, respiratory pattern curve, cycle number, etc. could be set to meet different test needs.
- English/Chinese switchable interface is convenient for operation.
- The parameters are calculated automatedly, also curves of breath flow volume and tidal volume can be displayed in real-time.
Application
Specification
| Dimensions | 70x35x62cm |
| Weight | 35Kg |
| Power rate | 0.85KW |
| Max. Tidal Volume | 1000ml |
| Precision | Max. TV±5% or Max. TV±1ml |
| Power supply | 220V, 50Hz |
| Item | Adult | Neonate | Infant | Child |
|---|---|---|---|---|
| Tidal Volume | 500ml | 25ml | 50ml | 155ml |
| Respiratory Rate | 15 cycles/min | 40 cycles/min | 30 cycles/min | 25 cycles/min |
| Breathing Profile Curve | Sine type | Sine type | Sine type | Sine type |
| I/E ratio | 1:1 | 1:3 | 1:3 | 1:2 |
Environmental Conditions
Humidity: 5% -95% (non-condensing state)
Humidity: 5% -95% (non-condensing state)
Components
The instrument consists of a filter sampler and a breath simulator host. The filter sampler includes a filter paper and holder. The low-resistance filter paper enables quantitative aerosol collection and active substance recovery using appropriate solvents. The filter holder has a dead volume of less than 10% of the standard adult tidal volume.
The breath simulator host comprises five modules:
- 1. Drive module: High-precision servo motor with full closed-loop control, 4M max input frequency, friction compensation, and anti-collision function.
- 2. Transmission module: High-precision ball screw offering low friction, high efficiency and accuracy, high axial stiffness, and low backlash.
- 3. Motion module: High-precision stainless steel piston and cylinder, powered by an AC servo unit with DSP, FPGA, and PIM for vibration suppression.
- 4. Control module: Laser galvanometer motion controller (DSP + FPGA) with a 250μs control cycle and up to 1000 data points per second.
- 5. Display module: Real-time display of flow rate and tidal volume curves.
Compliance
Frequently Asked Questions
Which pharmacopoeia standards does this breath simulator comply with?
The simulator is fully compliant with USP, Ph. Eur., and ChP 2020 standards, ensuring reliable regulatory alignment for inhalation drug product testing.
What is the range of tidal volume adjustments on this device?
The tidal volume setting range spans from 0 to 1000 ml, allowing you to accurately simulate breathing profiles for adult, child, infant, and neonate subjects.
What parameters can be customized by the user?
Users can define multiple parameters to suit specific experimental needs, including tidal volume, respiratory rate, I/E ratio, respiratory pattern curves, and cycle numbers.
Why is the HRH-BRM2100 ideal for Nebulizer DDU testing?
It features a high-precision servo motor and a zero-backlash ball-screw slide table that translates rotational motion into absolute linear piston displacement. This eliminates volumetric lag and replicates real-world breathing patterns with 100% fidelity.
Can I view flow and volume curves in real-time?
Yes, the system is equipped with a high-speed fluid algorithm and display module that dynamically plots and displays flow rate and tidal volume curves in real-time.
What are the environmental requirements for storage and operation?
The working environment should be kept between 0°C and 60°C, and the storage environment between -20°C and 70°C. Both environments require a non-condensing relative humidity range of 5% to 95%.