Breathing Simulator HRH-BRM2100 for Nebulizer Testing - Trusted China Suppliers and Factory
Features
- USP, Ph. Eur. and ChP 2020 compliant.
- Tidal volume setting range is 0-1000ml.
- Built-in parameters for four standard respiratory modes specified in Pharmacopoeia including standard adult, standard child, standard infant and standard neonate.
- User-defined parameters: tidal volume, respiratory rate, I/E ratio, respiratory pattern curve, cycle number, etc. could be set to meet different test needs.
- English/Chinese switchable interface is convenient for operation.
- The parameters are calculated automatedly, also curves of breath flow volume and tidal volume can be displayed in real-time.
Application
For Nebulizer DDU Tests
In the in vitro evaluation of inhalation drug products, accurately replicating the patient's real‑world breathing pattern is the key to assessing the device's true drug delivery performance. The HRH‑BRM2100 incorporates an exceptionally high‑order precision drive architecture. The system is equipped with an ultra‑low friction 1‑L precision cylinder, driven by an industrial‑grade high‑torque servo motor coupled with a zero‑backlash ball‑screw slide table. This rigid mechanical linkage translates the motor's millisecond‑scale rotational motion into the piston's absolute linear displacement with 100% fidelity, completely eliminating volumetric lag.
Designed for standard routine testing scenarios, this 1‑L breath simulator features a powerful micro‑controller system pre‑loaded with all standard physiological breathing parameters as specified in pharmacopoeias. Users can operate the device via a keyboard and mouse, inputting tidal volume (0–1000 mL), respiratory rate, and inspiratory‑to‑expiratory (I/E) ratio according to experimental requirements. In addition, the system's built‑in high‑speed fluid algorithm dynamically plots real‑time flow and tidal volume waveforms, providing full visibility into the airflow dynamics and equipment status throughout the entire test cycle.
Specification
| Dimensions | 70x35x62cm |
| Weight | 35Kg |
| Power rate | 0.85KW |
| Max. Tidal Volume | 1000ml |
| Precision | Max. TV±5% or Max. TV±1ml |
| Power supply | 220V, 50Hz |
Different Breath Characteristics of Breath Simulator
| Item | Adult | Neonate | Infant | Child |
|---|---|---|---|---|
| Tidal Volume | 500ml | 25ml | 50ml | 155ml |
| Respiratory Rate | 15 cycles/min | 40 cycles/min | 30 cycles/min | 25 cycles/min |
| Breathing Profile Curve | Sine type | Sine type | Sine type | Sine type |
| I/E ratio | 1:1 | 1:3 | 1:3 | 1:2 |
Working Environment
Temperature: 0°C-60°C
Humidity: 5% -95% (non-condensing state)
Humidity: 5% -95% (non-condensing state)
Storage Environment
Temperature: -20°C-70°C
Humidity: 5% -95% (non-condensing state)
Humidity: 5% -95% (non-condensing state)
Components
The instrument consists of a filter sampler and a breath simulator host. The filter sampler includes a filter paper and holder. The low-resistance filter paper enables quantitative aerosol collection and active substance recovery using appropriate solvents. The filter holder has a dead volume of less than 10% of the standard adult tidal volume.
The breath simulator host comprises five modules:
- 1. Drive module: High-precision servo motor with full closed-loop control, 4M max input frequency, friction compensation, and anti-collision function.
- 2. Transmission module: High-precision ball screw offering low friction, high efficiency and accuracy, high axial stiffness, and low backlash.
- 3. Motion module: High-precision stainless steel piston and cylinder, powered by an AC servo unit with DSP, FPGA, and PIM for vibration suppression.
- 4. Control module: Laser galvanometer motion controller (DSP + FPGA) with a 250μs control cycle and up to 1000 data points per second.
- 5. Display module: Real-time display of flow rate and tidal volume curves.
Compliance
USP, Ph.Eur. and ChP 2020
Frequently Asked Questions
Which pharmacopoeia standards does this breath simulator comply with?
The breath simulator is fully compliant with USP, Ph. Eur., and ChP 2020 regulatory standards.
What is the tidal volume setting range for the system?
The tidal volume setting range of the system is 0 to 1000ml, with a precision of Max. TV±5% or Max. TV±1ml.
What standard respiratory modes are pre-built into the device?
It features built-in parameters for four standard respiratory modes specified in Pharmacopoeia: standard adult, standard child, standard infant, and standard neonate.
What are the core modules that make up the breath simulator host?
The breath simulator host comprises five main modules: the Drive module, Transmission module, Motion module, Control module, and Display module.
What are the temperature and humidity requirements for the working environment?
The operational temperature range is 0°C to 60°C, and the humidity must be between 5% and 95% in a non-condensing state.