Request a Quote
Leave Your Message

Canine Nose-only Exposure System for Acute Inhalation Tests - China Suppliers & Factory Solutions

The Canine Nose-only Exposure System is a state-of-the-art solution designed for conducting comprehensive inhalation tests on canines. This system enables acute, subacute, chronic, and sub-chronic studies of canine exposure to a variety of substances, including gas, vapor, liquid aerosols, solid aerosols, and nanoparticle aerosols. As a leading manufacturer in China, we take pride in supplying high-quality exposure systems to laboratories and research facilities. Our factory ensures that each unit meets strict safety standards and delivers reliable results for your research needs. Trust us as your preferred supplier for advanced inhalation testing solutions in the industry

    Features

    Adopt stainless steel double static pressure chamber structure, it can perform inhalation tests for 6-10 canines simultaneously.
    The uniformity and stability deviation of each exposure port's mass concentration during tests for gas is within ±8%, for liquid aerosol is within ±10%, while for dust aerosol is within ±20%, which conforms to technical requirements of OECD guidelines.
    Achieve dynamic monitoring of the test article mass concentration, in compliance with OECD TG 403 and OECD TG 436.
    Enable real-time online detection of aerosol particle size distribution and manual particle size analysis (optional).
    Waste gas can fully meet Safety Emission Standards after treatment.
    The unique structural and air pressure control of exposure system ensures tight protection. Protection alarm is effective against abnormal temp, abnormal pressure difference and gas leakage.
    Unique human machine interface (HMI) for intuitive and convenient operation. Powerful software and hardware supporting system; the software complies with GLP requirements.

    Application

    Drug Safety Evaluation

    Inhalation Immunity and Environment Assessment

    Respiratory Disease Modeling and Drug Efficacy Evaluation

    Hazard Assessment and Radioactive Substances Protection

    Aerospace Medicine

    Components

    1. Aerosol Dilution Unit:

    Vortex mixed dilution by adopting uninterruptible cone gapless slit technology.

    2. Aerosol Gas Supply and Extraction Static Pressure Chamber:

    Dilute aerosols and stabilize at the required concentration rapidly and non-destructively by unique patented cone gapless slit technology. Main structure is made of SS316L with excellent performances such as high temp resistance, corrosion resistance, fire and explosion-proof, easy to clean, etc.

    3. Canine Fixed Car:

    Main structure is welded with high quality stainless steel, which is corrosion resistant and easy to clean. Animals can be flexibly fixed, which both meet animal standing/ leaning changing and can prevent violent movements affecting test accuracy. One fixed car for one dog. Animal support plate and fixed part can be adjusted to meet requirements of different canine animal tests.

    4. Nose-only Inhalation Exposure Mask:

    For nose-only inhalation exposure of awake canine animals. Suitable mouth and nose mask with good fitness. The contact part is made of comfortable soft silicone.

    5. Liquid Aerosol Generator:
    • Aerosol particle size distribution is MMAD1-3μm, GSD1.5-3 which meets 403 Acute Inhalation Toxicity and other standards.
    • Atomized by compressed air heatlessly, liquid samples can be generated into even and stable aerosol;
    • Applicable to various water-soluble and oil-soluble liquid samples and suspensions with some stable fine particles;
    • Applicable to aerosol generating from rare samples in large dose;
    • Applicable to microbial aerosol generation with minimal damage on microorganisms, and can be applied to animal inhalation infection models and related research;
    • Made of medical-grade SS316L, Teflon and high borosilicate glass, which are anti-corrosion and can be autoclaved.
    Model Nozzle number Rated gas flow
    HRH-WAG1 1 2L/min
    HRH-WAG3 3 6L/min
    HRH-WAG6 6 12L/min
    HRH-WAG1M Micro liquid 1 nozzle 2L/min
    HRH-WAG3M Micro liquid 3 nozzles 6L/min
    HRH-WAG6M Micro liquid 6 nozzles 12L/min
    HRH-WAG12 12 24L/min
    HRH-WAG24 24 48L/min
    6. Dust Aerosol Generator:
    • MMAD (Mass Median Aerodynamic Diameter): 1-4μm (ISO 12103-A2 Fine Test Dust), GSD1.5-3.
    • Offer report copy of dust particles aerodynamic particle size distribution generated by dust aerosol generator, issued by Academy of Military Medical Sciences;
    • Working method: gradual expansion by rotating divergent brush;
    • Particles: non-sticky powder or dust;
    • Computer control: independent control system with real-time display of parameters, including gas source pressure, gas flow, powder mass flow, theoretical concentration, remaining working time and feeding speed, etc.;
    • Dust loading: 10ml, 40ml, 300ml optional;
    • Particle size: 0.1~20μm;
    • Mass flow: 10~20000mg /min adjustable;
    • Aerosol flow: 5~100L /min adjustable;
    • Brush rotating speed: 600~1000rpm adjustable;
    • Delivery period: 10min~400h;
    • Dust residual: absolute value measured by electronic ruler;
    • Flow monitor: monitor and display automatically;
    • Dust mass concentration: calculate and display automatically;
    • Protection alarm: Six-fold intelligent detection and protection alarm.
    7. Membrane Weighing Sampler:

    Used to sample dry powder aerosol and non-volatile liquid aerosol by filtered weighing method. Timed auto-sampling technology can be realized by host control with sampling flow rate 0.1~5L/min, accuracy +1.0%F.S, time 0~6h adjustable.

    8. Porous Glass Sampler:

    Three-stage porous glass adsorptive sampler is used for sampling gases with absorbable properties and volatile liquid aerosol. Timed auto-sampling technology can be realized by host control with sampling flow rate 0.1~ 1L/min, accuracy ±1.0%F.S, time 0 ~ 6h adjustable. Each group of three-stage sampling tube can be used independently or in series.

    9. Aerodynamic Particle Sizer:
    • It is a low-flow particle size analysis sampler with inertial impact principle, used for stage sampling and weighing of aerosol particles and then calculating parameters such as MMAD and GSD, etc.;
    • Sampling flow rate 0.5L/min is ideal for particle size analysis in animal exposure tests.
    • The sampler is divided into 7 stages + membrane stage, cutting particle size of each stage as below:
    Stage Cutting Size (μm)
    1 5.1
    2 3.1
    3 1.9
    4 1.2
    5 0.77
    6 0.5
    7 0.33
    10. Control Cabinet:

    Collect real-time parameters such as temp, humidity, pressure difference, oxygen concentration, carbon dioxide and aerosol concentration inside cabinet; Control 4-way flow controllers of aerosol generation, dilution, sampling and total gas extraction volume; Control automatic devices such as gas extraction pump.

    11. Host Software:

    With functions of user classified management, the software can perform tests overall control, parameter setting, real-time monitoring and recording for environmental parameters during tests, real-time alarm and recording of abnormalities; Various test data storage and access, automatically issue reports post-test, etc.

    Specification

    Product Model Configuration
    Canine Nose-only Exposure System HRH-LMNE1168 Standard
    Canine Nose-only Exposure System HRH-LMNE1198 Premium

    Standards

    OECD Guidelines

    • OECD TG 403 Acute Inhalation Toxicity (2009).
    • OECD TG 436 Acute Inhalation Toxicity. Acute Toxic Class Method (2009).
    • OECD TG 412 28d Sub-acute inhalation (2018).
    • OECD TG 413 90d Sub-chronic inhalation (2018).

    Pesticide Registration Standards

    • GB /T 15670.6 ~2017 Toxicological test methods for pesticides registration—Part 6: Acute inhalation toxicity test.
    • GB /T 15670.12 ~ 2017 Toxicological test methods for pesticides registration—Part 12: Short-term repeated dose 28-day inhalation toxicity study.
    • GB /T 15670.13 ~2017 Toxicological test methods for pesticides registration—Part 13: Subchronic toxicity study.
    • GB /T 15670.26 ~ 2017 Toxicological test methods for pesticides registration—Part 26: Chronic toxicity study.

    Registration of New Chemical Substances by Ministry of Ecology and Environment

    • 403 Acute Inhalation Toxicity(2013, 2nd edition).
    • 436 Acute Inhalation Toxicity Test: Acute Toxic Class Method(2013, 2nd edition).
    • 412 Sub-acute inhalation:28-days test(2013, 2nd edition).
    • 413 Sub-chronic inhalation:90-days test(2013, 2nd edition).

    Frequently Asked Questions (FAQ)

    How many canines can be tested simultaneously in this system?

    The system adopts a stainless steel double static pressure chamber structure, enabling inhalation tests for 6 to 10 canines simultaneously.

    What is the deviation of the aerosol mass concentration during tests?

    The uniformity and stability deviation of each exposure port's mass concentration is within ±8% for gas tests, within ±10% for liquid aerosol, and within ±20% for dust aerosol, fully conforming to OECD guidelines.

    Which key international standards and guidelines does this system comply with?

    The system complies with OECD TG 403, OECD TG 436, OECD TG 412, and OECD TG 413, as well as Chinese Pesticide Registration Standards (GB/T 15670 series) and requirements for new chemical substance registration.

    What types of aerosols can be generated by this system?

    It supports both liquid aerosol generation (MMAD 1-3μm, suitable for water/oil-soluble samples and suspensions) and dust aerosol generation (MMAD 1-4μm, suitable for non-sticky powders or dust).

    What safety and alarm protections are integrated into the exposure system?

    The system features unique structural and air pressure controls to ensure tight protection. It includes alarms for abnormal temperatures, abnormal pressure differences, and gas leakage, while ensuring treated waste gas meets Safety Emission Standards.

    Does the host software comply with GLP requirements?

    Yes, the powerful host software is fully compliant with GLP requirements. It features user classification management, real-time monitoring and recording of environmental parameters, abnormal situation alarms, and automatic post-test report generation.

    Make An AppointmentLEAVE YOUR MESSAGE