Request a Quote
Leave Your Message

China Fully Automated Food Microbiology Station HRH-B20 - Top Suppliers & Factory for Efficient Testing

Introducing the HRH-B20 Fully Automated Food Microbiology Station, a revolutionary solution designed for food microbiology tests. This advanced system, manufactured in China, automates the entire sterile microbiology testing process, allowing for the simultaneous processing of 20 samples. With the capability to perform up to three bacteria pouring methods and one spreading method, it addresses common challenges in traditional testing, such as lengthy testing times, limited sample quantities, sensitivity issues, and operator contamination. Discover how our product, sourced from trusted suppliers and produced in our state-of-the-art factory, can enhance your food safety testing protocols today

    Features

    01

    Fully automated design: with built-in standard sample preparation programs for multi-species bacteria testing, the instrument could complete the whole process automatically after the user places samples and consumables well (Petri dishes, tubes, etc.).

    02

    Code scanning module: automatically identifies the QR code/barcode on the sterile bag, enters sample information into the system, and determines the specific programs.

    03

    Petri dish storage module: up to 396 empty and agar-filled Petri dishes can be stored to meet the spreading and pouring method requirements.

    04

    Liquid flapping and homogenizing module: dilute the samples with 10 times liquid, then homogenize the sample by auto-flapping. The integrated heat-sealing function retains the original homogenizing liquid.

    05

    Gradient dilution module: perform 10, 100, 1000 times gradient dilution for 20 samples. Cross-contamination is avoided by adopting 5ml disposable pipette tips.

    06

    Agar thermostatic function: magnetic stirring and thermal insulation functions ensure agar does not solidify or deposit. The pipeline is easy to dismantle and sterilize.

    07

    Pipetting module: with high precision, cross-contamination is avoided by adopting 5ml disposable pipette tips.

    08

    Bacterial spreading module: rotary and uniform spreading for each sample by an individually soft spreading stick to avoid cross-contamination and increase efficiency. After spreading, the agar can be overlaid by the top medium.

    09

    Agar filling module: up to 3 kinds of agar can be filled and shaken, and multi-species bacteria can be performed in one test. Working under metal bath insulation, the filling tube is reusable and easy to dismantle to sterilize.

    10

    Robotic arm: 2 sets of high-precision robotic arms with intelligent control, the program centralizes the scheduling of all modules to improve test efficiency.

    11

    Inkjet printing module: inkjet prints the information on Petri dishes, which makes it easy to distinguish the sample, gradient, parallel sample and other information.

    12

    UV sterilization: UV sterilize the system to prevent airborne bacteria contamination.

    13

    Aseptic environment: a laminar flow hood is set on top of the equipment, and the internal micro-positive pressure of the system ensures aseptic.

    14

    Multi-terminal remote monitoring: the software’s main interface and real-time images of the internal operation can be remotely monitored through mobile phones and computer clients.

    15

    Multi-functionality: can be used individually for sample flapping, pipetting, gradient dilution, Petri dish filling and other routine laboratory operations.

    Application

    It can automatically complete the determination of total colony count, coliform count, bifidobacteria test, Staphylococcus aureus test, Bacillus cereus test, Clostridium perfringens test, bifidobacteria test, lactobacillus test, Enterobacteriaceae test, Listeria monocytogenes test, molds and yeast counts, etc.

    Specification

    Item Technical Specification
    Model HRH-B20
    Sample throughput 20
    Bacteria Testing Throughput 3 pouring + 1 spreading assay (e.g., colony count, coliforms, mold yeast, aureus)
    Petri Dish Capacity 396
    Sample Processing Speed 140 min (4 bacteria), 70 min (total colony & coliform)
    Liquid Filling <1% RSD (n=25@250mL transfer volume by weight). Accuracy ±2%
    Flapping Homogenizing Speed 3~12 squeezes/sec
    Robotic Arm Dual robotic arms, accuracy 0.1mm
    Gradient Dilution 10/100/1000 times gradient dilution, 5ml pipetting, Precision ≤1%RSD (n=10@ 5mL). Accuracy ± 2%
    Agar pouring 3 agar filling ports, which can work independently with the shaking module. Agar volume and shaking speed can be set
    Pipetting Volume ≤ 5ml. Precision < 1% RSD (n=10 @ 5mL). Accuracy ± 1%
    Air supply 30L, 5Bar
    Power Supply 220VAC 50Hz
    Weight Approx. 400kgs
    Dimensions 1540mm×760mm×2200mm

    Configuration

    Host 1 set
    Industrial Control PC 1 set
    Air Pump 1 set
    Dedicated Control Software 1 set
    Φ6 PU Tube 3m
    Dilution tube 100 ea
    5ml Pipette tips 200 ea
    90mm Petri dish 500 ea
    Sterile sample bag 20 ea
    Certificate, Warranty Card, User Manual 1 set

    Frequently Asked Questions

    What is the sample throughput and Petri dish capacity of the HRH-B20?

    The HRH-B20 system supports a sample throughput of 20 samples and features a large storage capacity that holds up to 396 empty and agar-filled Petri dishes to meet various spreading and pouring requirements.

    How does the system prevent cross-contamination during testing?

    Cross-contamination is prevented by utilizing 5ml disposable pipette tips for gradient dilutions and pipetting, using individual soft spreading sticks for each sample, maintaining a positive pressure sterile environment with a top-mounted laminar flow hood, and using built-in UV sterilization.

    Which microbiological tests can be automatically performed?

    The station automatically performs determination for total colony count, coliform count, Bifidobacteria test, Staphylococcus aureus, Bacillus cereus, Clostridium perfringens, Lactobacillus, Enterobacteriaceae, Listeria monocytogenes, molds, and yeast counts.

    Can the system be monitored remotely?

    Yes, the system supports multi-terminal remote monitoring. Operators can remotely view the software's main interface and real-time internal cameras using mobile phones and computer clients.

    What are the processing speeds for the tests?

    The processing speed is approximately 140 minutes for 4 bacteria assays, and 70 minutes for total colony and coliform testing.

    Can the modules be used individually?

    Yes, the system is multi-functional and can be operated individually for routine laboratory tasks such as sample flapping, pipetting, gradient dilution, and Petri dish filling.

    Make An AppointmentLEAVE YOUR MESSAGE