Request a Quote
Leave Your Message

China Fully Automated Food Microbiology Station HRH-B20 | Top Suppliers & Factory for Sterile Testing Solutions

Introducing the HRH-B20 Fully Automated Food Microbiology Station, specifically engineered for comprehensive food microbiology testing. This advanced system, designed by leading suppliers in China, automates the entire sterile microbiology testing process, significantly enhancing efficiency and accuracy. Capable of processing up to 20 samples simultaneously, the HRH-B20 supports three bacteria pouring methods and one spreading method, addressing common challenges faced in traditional microbiology testing, such as prolonged testing times, limited sample quantities, sensitivity issues, and operator contamination. As a result, it stands out as a premier solution offered by top-tier factories dedicated to innovation in food safety testing

    Features

    Fully automated design

    With built-in standard sample preparation programs for multi-species bacteria testing, the instrument could complete the whole process automatically after the user places samples and consumables well (Petri dishes, tubes, etc.).

    Code scanning module

    Automatically identifies the QR code/barcode on the sterile bag, enters sample information into the system, and determines the specific programs.

    Petri dish storage module

    Up to 396 empty and agar-filled Petri dishes can be stored to meet the spreading and pouring method requirements.

    Liquid flapping & homogenizing

    Dilute the samples with 10 times liquid, then homogenize the sample by auto-flapping. The integrated heat-sealing function retains the original homogenizing liquid.

    Gradient dilution module

    Perform 10, 100, 1000 times gradient dilution for 20 samples. Cross-contamination is avoided by adopting 5ml disposable pipette tips.

    Agar thermostatic function

    Magnetic stirring and thermal insulation functions ensure agar does not solidify or deposit. The pipeline is easy to dismantle and sterilize.

    Pipetting module

    With high precision, cross-contamination is avoided by adopting 5ml disposable pipette tips.

    Bacterial spreading module

    Rotary and uniform spreading for each sample by an individually soft spreading stick to avoid cross-contamination and increase efficiency. After spreading, the agar can be overlaid by the top medium.

    Agar filling module

    Up to 3 kinds of agar can be filled and shaken, and multi-species bacteria can be performed in one test. Working under metal bath insulation, the filling tube is reusable and easy to dismantle to sterilize.

    Robotic arm

    2 sets of high-precision robotic arms with intelligent control, the program centralizes the scheduling of all modules to improve test efficiency.

    Inkjet printing module

    Inkjet prints the information on Petri dishes, which makes it easy to distinguish the sample, gradient, parallel sample and other information.

    UV sterilization

    UV sterilize the system to prevent airborne bacteria contamination.

    Aseptic environment

    A laminar flow hood is set on top of the equipment, and the internal micro-positive pressure of the system ensures aseptic.

    Multi-terminal remote monitoring

    The software’s main interface and real-time images of the internal operation can be remotely monitored through mobile phones and computer clients.

    Multi-functionality

    Can be used individually for sample flapping, pipetting, gradient dilution, Petri dish filling and other routine laboratory operations.

    Application

    It can automatically complete the determination of total colony count, coliform count, bifidobacteria test, Staphylococcus aureus test, Bacillus cereus test, Clostridium perfringens test, bifidobacteria test, lactobacillus test, Enterobacteriaceae test, Listeria monocytogenes test, molds and yeast counts, etc.

    Fully Automated Food Microbiology Station (1)
    Fully Automated Food Microbiology Station (2)

    Specification

    Item Technical Specification
    Model HRH-B20
    Sample throughput 20
    Bacteria Testing Throughput 3 pouring + 1 spreading assay (e.g., colony count, coliforms, mold yeast, aureus)
    Petri Dish Capacity 396
    Sample Processing Speed 140 min (4 bacteria), 70 min (total colony & coliform)
    Liquid Filling <1% RSD (n=25@250mL transfer volume by weight). Accuracy ±2%
    Flapping Homogenizing Speed 3~12 squeezes/sec
    Robotic Arm Dual robotic arms, accuracy 0.1mm
    Gradient Dilution 10/100/1000 times gradient dilution, 5ml pipetting, Precision ≤1%RSD (n=10@ 5mL). Accuracy ± 2%
    Agar pouring 3 agar filling ports, which can work independently with the shaking module. Agar volume and shaking speed can be set
    Pipetting Volume ≤ 5ml. Precision < 1% RSD (n=10 @ 5mL). Accuracy ± 1%
    Air supply 30L, 5Bar
    Power Supply 220VAC 50Hz
    Weight Approx. 400kgs
    Dimensions 1540mm×760mm×2200mm

    Configuration

    Component Quantity
    Host 1 set
    Industrial Control PC 1 set
    Air Pump 1 set
    Dedicated Control Software 1 set
    Φ6 PU Tube 3m
    Dilution tube 100 ea
    5ml Pipette tips 200 ea
    90mm Petri dish 500 ea
    Sterile sample bag 20 ea
    Certificate, Warranty Card, User Manual 1 set

    Frequently Asked Questions

    Q: What is the sample throughput and Petri dish capacity of the HRH-B20?

    The HRH-B20 Fully Automated Food Microbiology Station features a sample throughput of 20 samples and can store up to 396 empty or agar-filled Petri dishes to support continuous, large-scale laboratory operations.

    Q: How does the system prevent cross-contamination during testing?

    Cross-contamination is strictly prevented through multiple mechanisms: using disposable 5ml pipette tips for gradient dilutions and pipetting, employing individual soft spreading sticks for bacterial spreading, utilizing UV sterilization, and maintaining an aseptic working environment via a top-mounted laminar flow hood that creates internal micro-positive pressure.

    Q: What types of bacterial tests can this station automate?

    The system can automatically complete determination tests for total colony count, coliform count, bifidobacteria test, Staphylococcus aureus, Bacillus cereus, Clostridium perfringens, lactobacillus, Enterobacteriaceae, Listeria monocytogenes, as well as mold and yeast counts.

    Q: Can the HRH-B20 handle agar pouring and thermostatic control?

    Yes, the station features 3 agar filling ports that can work independently with the shaking module. Magnetic stirring and metal bath thermal insulation ensure that the agar remains in a liquid state without solidifying or depositing, and the pipeline is designed to be easily dismantled and sterilized.

    Q: Is remote monitoring available for this equipment?

    Yes, the system supports multi-terminal remote monitoring. Operators can view the software's main interface and real-time internal operation camera feeds remotely using mobile phones or computer clients.

    Make An AppointmentLEAVE YOUR MESSAGE