China Fully Automated Food Microbiology Station HRH-B20 | Top Suppliers & Factory for Sterile Testing Solutions
Features
Fully automated design
With built-in standard sample preparation programs for multi-species bacteria testing, the instrument could complete the whole process automatically after the user places samples and consumables well (Petri dishes, tubes, etc.).
Code scanning module
Automatically identifies the QR code/barcode on the sterile bag, enters sample information into the system, and determines the specific programs.
Petri dish storage module
Up to 396 empty and agar-filled Petri dishes can be stored to meet the spreading and pouring method requirements.
Liquid flapping & homogenizing
Dilute the samples with 10 times liquid, then homogenize the sample by auto-flapping. The integrated heat-sealing function retains the original homogenizing liquid.
Gradient dilution module
Perform 10, 100, 1000 times gradient dilution for 20 samples. Cross-contamination is avoided by adopting 5ml disposable pipette tips.
Agar thermostatic function
Magnetic stirring and thermal insulation functions ensure agar does not solidify or deposit. The pipeline is easy to dismantle and sterilize.
Pipetting module
With high precision, cross-contamination is avoided by adopting 5ml disposable pipette tips.
Bacterial spreading module
Rotary and uniform spreading for each sample by an individually soft spreading stick to avoid cross-contamination and increase efficiency. After spreading, the agar can be overlaid by the top medium.
Agar filling module
Up to 3 kinds of agar can be filled and shaken, and multi-species bacteria can be performed in one test. Working under metal bath insulation, the filling tube is reusable and easy to dismantle to sterilize.
Robotic arm
2 sets of high-precision robotic arms with intelligent control, the program centralizes the scheduling of all modules to improve test efficiency.
Inkjet printing module
Inkjet prints the information on Petri dishes, which makes it easy to distinguish the sample, gradient, parallel sample and other information.
UV sterilization
UV sterilize the system to prevent airborne bacteria contamination.
Aseptic environment
A laminar flow hood is set on top of the equipment, and the internal micro-positive pressure of the system ensures aseptic.
Multi-terminal remote monitoring
The software’s main interface and real-time images of the internal operation can be remotely monitored through mobile phones and computer clients.
Multi-functionality
Can be used individually for sample flapping, pipetting, gradient dilution, Petri dish filling and other routine laboratory operations.
Application
It can automatically complete the determination of total colony count, coliform count, bifidobacteria test, Staphylococcus aureus test, Bacillus cereus test, Clostridium perfringens test, bifidobacteria test, lactobacillus test, Enterobacteriaceae test, Listeria monocytogenes test, molds and yeast counts, etc.
Specification
| Item | Technical Specification |
|---|---|
| Model | HRH-B20 |
| Sample throughput | 20 |
| Bacteria Testing Throughput | 3 pouring + 1 spreading assay (e.g., colony count, coliforms, mold yeast, aureus) |
| Petri Dish Capacity | 396 |
| Sample Processing Speed | 140 min (4 bacteria), 70 min (total colony & coliform) |
| Liquid Filling | <1% RSD (n=25@250mL transfer volume by weight). Accuracy ±2% |
| Flapping Homogenizing Speed | 3~12 squeezes/sec |
| Robotic Arm | Dual robotic arms, accuracy 0.1mm |
| Gradient Dilution | 10/100/1000 times gradient dilution, 5ml pipetting, Precision ≤1%RSD (n=10@ 5mL). Accuracy ± 2% |
| Agar pouring | 3 agar filling ports, which can work independently with the shaking module. Agar volume and shaking speed can be set |
| Pipetting | Volume ≤ 5ml. Precision < 1% RSD (n=10 @ 5mL). Accuracy ± 1% |
| Air supply | 30L, 5Bar |
| Power Supply | 220VAC 50Hz |
| Weight | Approx. 400kgs |
| Dimensions | 1540mm×760mm×2200mm |
Configuration
| Component | Quantity |
|---|---|
| Host | 1 set |
| Industrial Control PC | 1 set |
| Air Pump | 1 set |
| Dedicated Control Software | 1 set |
| Φ6 PU Tube | 3m |
| Dilution tube | 100 ea |
| 5ml Pipette tips | 200 ea |
| 90mm Petri dish | 500 ea |
| Sterile sample bag | 20 ea |
| Certificate, Warranty Card, User Manual | 1 set |
Frequently Asked Questions
Q: What is the sample throughput and Petri dish capacity of the HRH-B20?
The HRH-B20 Fully Automated Food Microbiology Station features a sample throughput of 20 samples and can store up to 396 empty or agar-filled Petri dishes to support continuous, large-scale laboratory operations.
Q: How does the system prevent cross-contamination during testing?
Cross-contamination is strictly prevented through multiple mechanisms: using disposable 5ml pipette tips for gradient dilutions and pipetting, employing individual soft spreading sticks for bacterial spreading, utilizing UV sterilization, and maintaining an aseptic working environment via a top-mounted laminar flow hood that creates internal micro-positive pressure.
Q: What types of bacterial tests can this station automate?
The system can automatically complete determination tests for total colony count, coliform count, bifidobacteria test, Staphylococcus aureus, Bacillus cereus, Clostridium perfringens, lactobacillus, Enterobacteriaceae, Listeria monocytogenes, as well as mold and yeast counts.
Q: Can the HRH-B20 handle agar pouring and thermostatic control?
Yes, the station features 3 agar filling ports that can work independently with the shaking module. Magnetic stirring and metal bath thermal insulation ensure that the agar remains in a liquid state without solidifying or depositing, and the pipeline is designed to be easily dismantled and sterilized.
Q: Is remote monitoring available for this equipment?
Yes, the system supports multi-terminal remote monitoring. Operators can view the software's main interface and real-time internal operation camera feeds remotely using mobile phones or computer clients.