China HRH-TSM610 Ten-Channel Turntable Smoking Generator - Leading Suppliers and Factory for Cigarette Smoke Testing
Features
Smoke channel: 10
Smoke capacity: 15-60ml
Smoke cycle: 30-240s
Cigarette bin capacity: 200 cigarettes
Combustion abort mode: by smoke number
Smoke curve: standard bell curve or other customized curves
Application
Applicable to various toxicology research centers, animal smoking poisoning tests, respiratory laboratories of hospitals, technical laboratories of cigarette factories for smoke research, etc.
Working Environment
- Temperature: 0°C-60°C
- Humidity: 5%-95% (non-condensing)
Storage Environment
- Temperature: -20°C -70°C
- Humidity: 5%-95% (non-condensing)
Two smoking modes
Puff Mode and Length Mode. Both modes support automatic cigarette loading, lighting, smoking, and ejection.
In this mode, the instrument records the number of puffs per cigarette. When the number of puffs per cigarette reaches the preset value, the cigarette will be ejected and a new cigarette will be inserted. The instrument will automatically stop and issue a reminder when the total number of puffs taken equals the preset total puffs.
In this mode, cigarette ejection is performed by detecting whether the cigarette length reaches the user‑set length. The next round of operation will start only after all 10 cigarettes in the current round reach the specified length. The instrument will automatically stop and issue a reminder when the total number of cigarettes reaches the preset value.
- Puff Flow Rate The flow rate for drawing a single puff. Adjustment range: 10 mL–60 mL.
- Puffs per Cigarette Sets the number of puffs per cigarette in Puff Mode. This button is grayed out and disabled in Length Mode.
- Total Puffs Sets the total number of puffs in Puff Mode. This button is grayed out and disabled in Length Mode.
Frequently Asked Questions
What is the cigarette capacity of the machine's bin?
The cigarette bin has a capacity of 200 cigarettes.
Which fields and industries can use this smoking instrument?
It is applicable to various toxicology research centers, animal smoking poisoning tests, respiratory laboratories of hospitals, and technical laboratories of cigarette factories for smoke research.
What are the environmental requirements for storage and operation?
For working environment, the temperature should be 0°C-60°C with 5%-95% non-condensing humidity. For storage, the temperature range is -20°C to 70°C with 5%-95% non-condensing humidity.
What is the difference between Puff Mode and Length Mode?
Puff Mode operates and ejects cigarettes based on the recorded number of puffs per cigarette. Length Mode performs cigarette ejection by detecting whether the cigarette has reached the user-set length.
What is the adjustable range for the Puff Flow Rate?
The flow rate for drawing a single puff can be adjusted within the range of 10 mL to 60 mL.