China HRH-VOC186 VOC Generator Factory: Reliable Suppliers for Controlled Volatile Organic Compounds Evaporation
Features
- Gas concentration generated is controllable and with high continuous stability.
- Adopt glass ball stack convective volatilization structure with fast volatilization speed.
- Assist heating volatile gas, temp can be controlled.
- Generating system is closed with high safety.
- Volatilization rate: 0-5mL/min, gas flow rate: 0-20L/min, heating temp: 20-60℃.
Application
- Inhalation Toxicity Tests on VOC.
- Health Risk Assessment of Environmental Atmosphere and Indoor Volatile Solvents.
- Inhalation Toxicity Studies of VOC or Petrochemicals in Occupational Sites.
- Online Monitor and Control for VOC.
Specification
| Volatilization rate | 0-5mL/min |
| Gas flow rate | 0-20L/min |
| Heating temperature | 20-60℃ |
Working principle
The volatile sample is quantitatively injected into the volatilization pipeline filled with glass beads through the sample transfer pump, the superficial area of the dropped sample is increased enough to allow for faster volatilization and the clean air is heated by the air heater to enter the cushion chamber, and then the sample volatilization is promoted by the glass sphere pile and volatilized samples and air can be imported into the exposure system through the outlet for contamination. There is a temperature probe at the outlet of VOC gas for detecting the temperature of the outlet gas, the temperature value is fed back to the air heater, and the heater is used to intelligently adjust the heating power according to the outlet temperature set by the user.
Note:
1. VOC concentration = liquid sample mass/ (liquid sample gasification expansion volume + air volume);
When the experimental concentration of VOC is designed to be relatively low, the concentration of VOC is ≈ liquid sample mass/air volume;
2. The temperature value set by the air heater is the temperature of the air outlet of the VOC system other than the hot air temperature after heating;
3. To be able to quantify the VOC content, the injection rate of the sample cannot exceed the maximum volatilization rate, that's to say that it's necessary to ensure that the sample injected into the volatilization tube is completely volatilized, and no liquid flows into the cushion chamber.
4. The temperature setting method is as follows: The temperature control mode is that the system will automatically stop the air heating when the air outlet temperature is greater than the set upper limit; the system will automatically enable the air heating when the temperature is less than the set lower limit.
1. VOC concentration = liquid sample mass/ (liquid sample gasification expansion volume + air volume);
When the experimental concentration of VOC is designed to be relatively low, the concentration of VOC is ≈ liquid sample mass/air volume;
2. The temperature value set by the air heater is the temperature of the air outlet of the VOC system other than the hot air temperature after heating;
3. To be able to quantify the VOC content, the injection rate of the sample cannot exceed the maximum volatilization rate, that's to say that it's necessary to ensure that the sample injected into the volatilization tube is completely volatilized, and no liquid flows into the cushion chamber.
4. The temperature setting method is as follows: The temperature control mode is that the system will automatically stop the air heating when the air outlet temperature is greater than the set upper limit; the system will automatically enable the air heating when the temperature is less than the set lower limit.
Frequently Asked Questions
What is the volatilization rate of the VOC generation system?
The system supports a controlled volatilization rate ranging from 0 to 5 mL/min.
What is the range of the gas flow rate?
The gas flow rate can be adjusted and controlled within the range of 0 to 20 L/min.
Can the heating temperature be controlled?
Yes, the heating temperature is controllable and can be set between 20℃ and 60℃.
What are the primary applications for this system?
It is primarily used for VOC inhalation toxicity tests, environmental and indoor solvent health risk assessments, occupational site toxicity studies, and online VOC monitoring.
How does the system ensure high volatilization speed?
The system utilizes a glass ball stack convective volatilization structure, which increases the superficial area of the dropped sample to ensure faster and more efficient volatilization.
Is the VOC gas generation system safe to operate?
Yes, the gas generation system is completely closed, ensuring a high level of safety during operation.