China PM2.5 Online Enriched Rodent Whole-body Exposure System - Leading Suppliers and Factory for Health Research
Features
Cutting size and collection efficiency of PM2.5 sampler can meet requirements of HJ93-2013 Specifications and test procedures for PM10 and PM2.5 sampler regulated by Ministry of Environmental Protection.
6-10 concentration times.
High output flow: up to 40-60L/min.
Application
- Relationship studies between environmental particulate pollution and human health.
- Animal haze pathogenesis modeling.
- Modeling, pathogenesis and drug intervention mechanism of asthma, airway hyperresponsiveness, chronic obstructive pulmonary disease, pulmonary fibrosis, acute/neonatal respiratory distress syndrome and acute pulmonary injury.
Working Principle
Air passes through the impact cutter, where particles larger than 2.5μm in diameter are removed, leaving only PM2.5 particles. The air then passes through a two-stage slit virtual impactor, which separates particles below 0.1μm, thereby concentrating the PM2.5 fraction. The concentrated PM2.5 then enters the dilution system, where it is mixed with dilution air before entering the whole-body exposure system.
- 1. The PM2.5 cutting head uses a two-stage cut at 10μm and 2.5μm to remove particles larger than these respective sizes from the air, ensuring effective cut-off performance.
- 2. The system employs a slit-type virtual impactor, which effectively ensures cut-off performance while minimizing particle loss.
Routine Maintenance
Regularly clean the insect screen of the impactor cutter. It is recommended to replace it once per week.
Regularly clean the impaction plate of the impactor cutter. Under normal use, it is recommended to replace it once per week.
If the differential pressure in the whole-body exposure system is found to be too high, please clean the slit-type virtual impactor. When cleaning, please note: Do not strike the slit nozzle with hard objects, and DO NOT use acidic or alkaline cleaning agents!
Specification
| Item | Model | Specification |
|---|---|---|
| PM2.5 Online Enriched Rodent Whole-body Exposure System | HRH-PM186 | 0.3cbm: number of test animals: up to 40 rats (single cage for single animal) |
| PM2.5 Online Enriched Rodent Whole-body Exposure System | HRH-PM286 | 1cbm: number of test animals: up to 96 rats (single cage for single animal) |
Standards
HJ 93-2013 Specifications and test procedures for PM10 and PM2.5 sampler
Frequently Asked Questions
Q1 Does the PM2.5 sampler meet national environmental standards?
Yes. The cutting size and collection efficiency of the PM2.5 sampler fully meet the requirements of the HJ93-2013 Specifications and test procedures for PM10 and PM2.5 sampler regulated by the Ministry of Environmental Protection.
Q2 What is the output flow rate and concentration capability of the system?
The system features 6-10 concentration times and delivers a high output flow rate of up to 40-60 L/min.
Q3 What are the primary applications for this exposure system?
It is designed for relationship studies between environmental particulate pollution and human health, animal haze pathogenesis modeling, and investigating the pathogenesis and drug intervention mechanisms of respiratory conditions such as asthma, airway hyperresponsiveness, COPD, pulmonary fibrosis, and acute lung injuries.
Q4 How does the system separate and concentrate PM2.5 particles?
Air passes through an impact cutter to remove particles larger than 2.5μm. It then goes through a two-stage slit virtual impactor to separate particles below 0.1μm, thereby concentrating the PM2.5 fraction before it is mixed with dilution air and directed into the exposure chamber.
Q5 What is the recommended maintenance schedule for the impactor cutter?
Under normal use, it is recommended to clean and replace both the insect screen and the impaction plate of the impactor cutter once per week.
Q6 What precautions should be taken when cleaning the slit-type virtual impactor?
If system differential pressure becomes too high, clean the impactor carefully. Do not strike the slit nozzle with hard objects, and absolutely DO NOT use acidic or alkaline cleaning agents.