Introducing the Non-Human Primate Nose-Only Exposure System, a cutting-edge solution designed for rigorous inhalation testing. This system allows researchers to conduct acute, subacute, chronic, and sub-chronic tests on primates, facilitating exposure to a variety of substances including gases, vapors, liquid aerosols, solid aerosols, and nanoparticle aerosols. As a leading supplier in China, our factory ensures high-quality manufacturing standards, making this system an essential tool for scientific studies and pharmaceutical research. Experience reliable and efficient inhalation testing with our advanced nasal exposure technology.

    Key Features

    Adopt stainless steel double static pressure chamber structure and special primate mask, it can perform inhalation tests for 6-10 primates simultaneously.

    The uniformity and stability deviation of each exposure port's mass concentration during tests for gas is within ±8%, for liquid aerosol is within ±10%, while for dust aerosol is within ±20%, which conforms to technical requirements of OECD guidelines.

    Waste gas can fully meet Safety Emission Standards after treatment.

    The unique structural and air pressure control of exposure system ensures tight protection. Protection alarm is effective against abnormal temp, abnormal pressure difference and gas leakage.

    Applications

    Drug Safety Evaluation
    Inhalation Immunity and Environment Assessment
    Respiratory Disease Modeling and Drug Efficacy Evaluation
    Hazard Assessment and Radioactive Substances Protection
    Aerospace Medicine

    System Components

    1. Aerosol Dilution Unit

    Vortex mixed dilution by adopting uninterruptible cone gapless slit technology.

    2. Aerosol Gas Supply and Extraction Static Pressure Chamber

    Dilute aerosols and stabilize at the required concentration rapidly and non-destructively by unique patented cone gapless slit technology. Main structure is made of SS316L with excellent performances such as high temp resistance, corrosion resistance, fire and explosion-proof, easy to clean, etc.

    3. Monkey Chair

    • Material: high-strength plastic, corrosion-resistant nylon straps;

    • Fixed positions: 6 places (limbs, neck and waist);

    • Strap distance: adjustable;

    • Monkey chair height: adjustable;

    • Applicable monkey size: 3-6Kg.

    4. Inhalation Masks

    Monkey Mouth and Nose Mask: For monkey nose-only inhalation exposure under anesthesia. With customized design and silicone material, it fits well with macaque's mouth and nose. It can be autoclaved or sterilized with conventional disinfectants. Specially reserved aerosol channel is similar with natural breathing. Applicable monkey size: 3-6kg.

    Monkey Head Mask: For monkey head inhalation exposure in awake state. The main structure is made of high-quality transparent material. The contact part with monkey's neck adopts latex material, which is more comfortable and resistance to hydrogen peroxide sterilization. Applicable monkey size: 3-6kg.

    5. Liquid Aerosol Generator

    a. Aerosol particle size distribution is MMAD1-3μm, GSD1.5-3 which meets 403 Acute Inhalation Toxicity and other standards.

    b. Atomized by compressed air heatlessly, liquid samples can be generated into even and stable aerosol;

    c. Applicable to various water-soluble and oil-soluble liquid samples and suspensions with some stable fine particles;

    d. Applicable to aerosol generating from rare samples in large dose;

    e. Applicable to microbial aerosol generation with minimal damage on microorganisms, and can be applied to animal inhalation infection models and related research;

    f. Made of medical-grade SS316L, Teflon and high borosilicate glass, which are anti-corrosion and can be autoclaved.

    Model Nozzle number Rated gas flow
    HRH-WAG1 1 2L/min
    HRH-WAG3 3 6L/min
    HRH-WAG6 6 12L/min
    HRH-WAG1M Micro liquid 1 nozzle 2L/min
    HRH-WAG3M Micro liquid 3 nozzles 6L/min
    HRH-WAG6M Micro liquid 6 nozzles 12L/min
    HRH-WAG12 12 24L/min
    HRH-WAG24 24 48L/min

    Standards & Guidelines

    OECD Guidelines

    • ① OECD TG 403 Acute Inhalation Toxicity (2009).
    • ② OECD TG 436 Acute Inhalation Toxicity. Acute Toxic Class Method (2009).
    • ③ OECD TG 412 28d Sub-acute inhalation (2018).
    • ④ OECD TG 413 90d Sub-chronic inhalation (2018).

    Pesticide Registration Standards

    • ① GB /T 15670.6 ~2017 Toxicological test methods for pesticides registration—Part 6: Acute inhalation toxicity test.
    • ② GB /T 15670.12 ~ 2017 Toxicological test methods for pesticides registration—Part 12: Short-term repeated dose 28-day inhalation toxicity study.
    • ③ GB /T 15670.13 ~2017 Toxicological test methods for pesticides registration—Part 13: Subchronic toxicity study.
    • ④ GB /T 15670.26 ~ 2017 Toxicological test methods for pesticides registration—Part 26: Chronic toxicity study.

    Registration of New Chemical Substances (MEE)

    • ① 403 Acute Inhalation Toxicity(2013, 2nd edition).
    • ② 436 Acute Inhalation Toxicity Test:Acute Toxic Class Method(2013, 2nd edition).
    • ③ 412 Sub-acute inhalation:28-days test(2013, 2nd edition).
    • ④ 413 Sub-chronic inhalation:90-days test(2013, 2nd edition).

    Typical Users

    Kunming Institute of Zoology, Chinese Academy of Sciences
    China Electronics System Engineering No. 2 Construction Co., Ltd.
    CESEC

    Frequently Asked Questions (FAQ)

    How many primates can undergo exposure testing simultaneously?

    The system utilizes a stainless steel double static pressure chamber structure and special primate masks to conduct simultaneous inhalation tests for 6 to 10 primates.

    What are the concentration stability and uniformity standards across ports?

    The exposure mass concentration deviation is within ±8% for gas, within ±10% for liquid aerosol, and within ±20% for dust aerosol, fully complying with OECD testing guidelines.

    What size monkeys are compatible with the masks and restraint chairs?

    Both the Monkey Chair and the inhalation masks (Mouth and Nose Mask, Head Mask) are designed for primates weighing between 3 kg and 6 kg.

    What is the difference between the Mouth & Nose Mask and the Head Mask?

    The Monkey Mouth and Nose Mask is designed for nose-only exposure under anesthesia, featuring silicone material that mirrors natural breathing. The Head Mask is intended for head-only inhalation exposure while the animal is in an awake state, constructed with transparent material and comfortable latex neck seal.

    What are the aerosol particle size characteristics generated by this equipment?

    The Liquid Aerosol Generator delivers an aerosol particle size distribution of MMAD 1–3 μm with a GSD of 1.5–3, satisfying standard OECD 403 Acute Inhalation Toxicity requirements.

    What safety and protection systems are included?

    The system features air pressure control for tight containment, automated alarms for abnormal temperature, pressure differential deviations, and gas leakage, as well as integrated treatment ensuring exhaust meets Safety Emission Standards.