Request a Quote
Leave Your Message

China Suppliers Factory Fully Automated QuEChERS System for Efficient and Accurate Pesticide Residue Analysis

The fully automatic QuEChERS pesticide residue preparation system is revolutionizing the way laboratories handle pesticide testing in China. As a leading supplier in the market, our factory offers an advanced solution that significantly enhances efficiency and accuracy in sample processing. Unlike traditional methods that are labor-intensive and prone to errors, our system integrates multiple automated functions including liquid, salt, and ceramic homogenizer feeding, oscillating, vortexing, centrifuging, an ice bath, and precision pipetting. Capable of processing 32, 40, 60, or even 120 samples in a single run, it eliminates manual intervention, reduces the risk of human error, and ensures reliable and reproducible results. Experience the future of pesticide residue analysis with our state-of-the-art automated QuEChERS system, designed to optimize testing processes and improve laboratory productivity

    Application

    QuEChERS sample preparation on plant-origin food, herbs, tobacco and imported & exported agricultural products, tea and herbs, etc.

    Components

    Fully Automated QuEChERS System (1)

    Features

    1

    Fully Automated Design

    The system established a standard preparation process for QuEChERS method. After placing samples and test tubes, the system can carry out actions automatically such as oscillating, vortexing, centrifugating, and pipetting.

    2

    Automated Salt and Ceramic Homogenizer Feeding

    The user-defined system can realize automatic and accurate feeding of mixed salt.

    3

    Oscillating Compatibility

    Four test tubes oscillate simultaneously with adjustable speed and time. The structure is compatible with 50ml/15ml test tubes.

    4

    Horizontal Centrifuge Module

    Integrate 4-rotor horizontal centrifuge and is compatible with 50ml/15ml test tubes simultaneously, with adjustable centrifugal time and speed.

    5

    Dual-channel Vortex Module

    Each channel is driven independently and vortex time is adjustable.

    6

    High-precision Pipetting Robot Arm

    Integrate high-precision pipetting module with precise liquid-level detection.

    7

    Automated Tip Replacement

    Replace tips for each pipetting to avoid cross-contamination.

    8

    Intelligent Syringe Pump

    Equipped with 4-way or 8-way switching valve, which can fully meet liquid filling requirements in routine tests. Real-time tube-level monitoring guarantees pipetting accuracy and reliability.

    9

    Ice Bath

    Meet requirements of the Pharmacopoeia.

    10

    Multi-directional Fault Monitoring

    Can monitor real-time failures of centrifugal weight match, cap screw/unscrew, tube delivering, ceramic homogenizer feeding, and other failures during operation, and feedback to the user interface in time.

    11

    Multi-terminal Remote Monitoring

    Monitor software main interface and real-time internal operation remotely via mobile phone and computer.

    12

    Module Integration

    Supports integration with automated filtration modules or nitrogen blow filtration modules.

    HMI

    1. Main Interface: Easy operation, real-time display status of function modules and procedure of online testing.
    Fully Automated QuEChERS System (2)
    2. Program Setting Interface: Test procedure is built-in and can be used directly, including pesticide residue QuEChERS preparation for vegetables and fruits, cereals and nuts. Program parameters can be adjusted and optimized per actual requirements, and also can be adjusted partially or by user design under guidance of manufacturer.
    Fully Automated QuEChERS System (3)
    3. Remote Monitor
    Fully Automated QuEChERS System (4)

    Specification

    Item Technical Parameters
    Model HRH-Q32 HRH-Q40 HRH-Q60 HRH-Q40PRO HRH-Q60PRO HRH-Q120
    Sample Throughput 32 /batch 40 /batch 60 /batch 40 /batch 60 /test 120 /batch
    Test Efficiency Est. 5min/sample, total 2hrs. 40min Est. 5.5min/sample, total 3hrs. 40min Est. 5.5min/sample, total 5hrs. 25min Est. 5min/sample, total 3hrs. 20min Est. 4.7min/sample, total 4hrs. 40min Est. 2.7min/sample, total 5hrs. 20min
    Filling Acc. ≤0.5% RSD, 4-way switch valve ≤0.5% RSD, 8-way switch valve
    Pipetting Acc. Vol.≤5ml, Acc.≤1% RSD Vol.≤1ml, Acc.≤1% RSD Vol.≤5ml, Acc.≤1% RSD
    Salt Adding Acc. ≤5%RSD
    1. Salt bin: ≤5%RSD
    2. Individual salt tube
    Shaking 4 stations, 0-500 RPM, speed and time adjustable 8 stations, 0-500 RPM, speed and time adjustable 8 stations, 0-1000RPM, speed and time adjustable
    Vortex Speed 2 stations, ≥3500RPM 8 stations, ≥3500RPM
    Centrifuge Speed 0-5000 RPM, speed and time adjustable
    Ice Bath Acc. / ±1℃
    Centrifuge Throughput 4 stations, compatible with 50ml/15ml tubes 8 stations, compatible with 50ml/15ml tubes
    Power Supply 220VAC 50Hz or customized
    Dimensions 1270×910×2100mm 1480×910×2100mm 2440×1010×2150mm

    Configuration

    Standard Host 1 set
    Industrial Controlled PC 1 set
    Air Compressor 1 set
    Dedicated Control Software 1 set
    Φ6 PU Tube 3m
    50mL Test Tube 1 bag
    15mL Test Tube 2 bags
    1mL Pipette Tip (HRH-Q40, HRH-Q60) 2 boxes
    5mL Pipette Tip (HRH-Q32, HRH-Q40PRO, HRH-Q60PRO, HRH-Q120) 2 boxes
    Ceramic Homogenizer 100 pcs
    Certificate, Warranty Card, User Manual 1 set
    Optional Built-in Filtration Module (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) 1 set
    Nitrogen Blow-Down Filtration Module (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) 1 set
    SPE Module for Veterinary Drug Residues (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) 1 set
    Integrated Salt Addition Module (for HRH-Q120 only) 1 set
    Chilled Extract Storage Module (for HRH-40PRO, HRH-60PRO only) 1 set
    Internal Standard (ISTD) Addition Module 1 set
    Multi-protocol Processing (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) 1 set

    Compliance

    1. GB 23200.113—2026 National Food Safety Standard Determination of 242 Pesticides and Metabolites Residues in Foods of Plant Origin - Gas Chromatography-tandem Mass Spectrometry Method.

    2. GB 23200.121—2026 National food safety standard—Determination of 352 pesticides and metabolites residues in foods of plant origin—Liquid chromatography-tandem mass spectrometry method.

    3. Pharmacopoeia of the People's Republic of China 2025 Edition (Volume IV), 2341 – Method 4 for the Determination of Pesticide Multiresidues: Determination of Pesticide Multiresidues (Mass Spectrometry); Method 5: Determination of Prohibited Pesticide Multiresidues in Medicinal Materials and Decoction Pieces (Botanical).

    4. AOAC 2007.01 Determination of pesticide residues in food using acetonitrile extraction and magnesium sulfate separation.

    5. EN 15662:2018 Foods of plant origin - Multimethod for the determination of pesticide residues using GC- and LC-based analysis following acetonitrile extraction/partitioning and clean-up by dispersive SPE - Modular QuEChERS-method.

    Frequently Asked Questions

    Q What samples can be prepared using this Fully Automated QuEChERS System?

    The system is designed for automated QuEChERS sample preparation on plant-origin food, herbs, tobacco, tea, and imported & exported agricultural products.

    Q How does the system prevent cross-contamination during operation?

    It features an automated tip replacement mechanism, ensuring that pipette tips are replaced after each pipetting step to completely avoid cross-contamination.

    Q Can I monitor the preparation process remotely?

    Yes, the system supports multi-terminal remote monitoring. You can monitor the main software interface and real-time internal operations via mobile phones or computers.

    Q What test tube sizes are compatible with the oscillating and centrifuge modules?

    Both the oscillating structures and the horizontal centrifuge module are compatible with standard 50ml and 15ml test tubes.

    Q Does the system comply with international pesticide residue determination standards?

    Yes, the system complies with major international standards including AOAC 2007.01, EN 15662:2018, as well as Chinese national standards GB 23200.113, GB 23200.121, and the 2025 Pharmacopoeia.

    Q What are the optional modules available for upgrading the system?

    Depending on the model, optional upgrades include built-in filtration modules, nitrogen blow-down filtration modules, SPE modules for veterinary drug residues, integrated salt addition modules, chilled extract storage, and internal standard (ISTD) addition modules.

    Make An AppointmentLEAVE YOUR MESSAGE