China Suppliers Factory Nasal Spray Fine Particle Dose Measuring Device for Accurate Drug Deposition Analysis

,

For effective drug delivery via nasal sprays, it is crucial to achieve optimal particle deposition in the nasal cavity rather than the lungs. Nasal products are designed to produce particles predominantly within the aerodynamic diameter range of 20-200 µm. However, it is important to note that a small proportion (5% or less) of particles may fall below 10 µm, resulting in deposition in the lower respiratory tract and lungs. To accurately assess the fine particle dose (FPD) generated by nasal sprays, the use of cascade impactors is essential. These devices are specifically designed to capture particles in the 0-10 µm range. By integrating a cascade impactor with a nasal spray expansion chamber, we can effectively measure the fine particle dose of drugs in both nasal sprays and nasal aerosols. As a leading factory in China, we are committed to providing high-quality products to our suppliers, ensuring adherence to optimal standards for nasal drug delivery.

,

    Nasal Spray Fine Particle Dose Measuring (1)

    Features

    Cascade impactors are used to capture 0-10μm particles. The combination of cascade impactor with nasal spray expansion chamber is used to measure fine particle dose of drugs in nasal sprays and nasal aerosols.

    Application

    Nasal Spray FPD Tests

    Specification

    • 1L capacity: used in nasal aerosols to maximize deposition below the top stage.
    • 2L capacity: used in nasal sprays to maximize nebulization and deposition.
    • 5L capacity: for some stronger nasal sprays, additional room is required to be able to generate aerosol plume.
    Notes: not mandatory to use the expansion chamber for Nasal Powder FPD testing, as its test method is the same as the Dry Powder Inhalers by equipping the same test instrument and accessories, no pre-separator is required.
    Nasal Spray Fine Particle Dose Measuring (2)

    Accessories

    part

    Inhaler Testing Data Analysis Software Instruction

    The main interface of the analysis software is shown in Figure 20. After inputting flow, the software will automatically calculate the cutting particle size. The information related to the experiment can be filled in on the right. The current experiment information can be saved by the Save button. Open the previously saved experiment information by the Open button and click the Next button to enter the data input interface after confirming the flow rate.

    In the data input interface, each column represents an experiment, and each row corresponds to a different stage of the device. The number of experiments can be selected on the right side of the data sheet, and open data files and save data as files by Open and Save Button. After data input is completed, click the Next button to enter the result display interface. The result display interface can display parameters (such as MMAD and GSD) of each experiment as well as particle size distribution fitting curve and scatter diagram. It's allowed to choose to display the curve of any experiment or the curve of all experiments. Click the right mouse button in terms of graphs to export the curve graph.

    Inhaler Testing Data Analysis Software Instruction
    Inhaler Testing Data Analysis Software Instruction1

    Compliance

    • FDA Bioavailability and Bioequivalence Studies for Nasal Aerosols and Nasal Sprays for Local Action (2003)
    • FDA Nasal Spray, Inhalation Solution, Suspension & Spray Drug Products (2002)
    • Nasal Preparations (Dosage Forms 0676) Ph.Eur. 2021 10.5

    Typical Users

    United Arab Emirates University
    Genix Pharma Private Limited
    Drug International Limited
    Endocrine Technologies Llc
    Novel Phase
    Divine Healthcare Pvt. Ltd.
    Cipla Ltd.
    JOINN Laboratories
    Pharmaron Beijing Co., Ltd.
    Boji Medical Technology Co., Ltd.
    Tianjin Pharmaceutical Research Institute Co., Ltd.
    China State Institute of Pharmaceutical Industry (Haimen) R&D Co., Ltd.
    Shenyang SYRICI Testing Co., Ltd (SYRICIT)
    Guangdong Zhongke Yinghai Tech Co., Ltd.
    Jiangsu Medicine Research Institute
    Chinese Academy of Sciences Shanghai Institute of Materia Medica
    Shenyang Pharmaceutical University Wuya College of Innovation
    Jiangxi University of Chinese Medicine
    Kunming Institute of Zoology. Cas
    Zhongshan Research Institute, Shanghai Institute of Materia Medica
    ZhongShan Institute for Drug Discovery
    Shanghai Xiandai Medicine Preparation Engineering Research Centre Co.,Ltd.
    Northeastern University
    China Institute for Radiation Protection
    Hubei Provincial Center for Disease Control and Prevention
    Inner Mongolia Medical University
    Weifang Medical University
    Suzhou Jingzida Testing Service Co., Ltd.
    Suzhou Inhal Pharma Co., Ltd.
    Zhejiang Cdmo Pharmaceutical Co., Ltd
    Hangzhou Zhezhong Pharmaceutical Technology Co., Ltd.
    Jinan Kangqiao Medical Technology Co., Ltd.
    Anhui JieXi Pharmaceutical Co., Ltd.
    Beijing Xingyuanxiang Biotechnology (Group) Co., Ltd.
    Hunan Prima Pharmaceutical Research Center Co., Ltd.
    Beijing Wehand-bio Pharmaceutical Co.,ltd
    Jinan Baohede Pharmaceutical Technology Co., Ltd.
    Shandong Innovative Drug Research and Development Co., Ltd.
    Zhongshan Liansi Chemical Technology Co., Ltd.
    Jiangxi Zhonglu Science & Technology Co., Ltd.
    Shanghai Zezheng Biopharmaceutical Co., Ltd.
    Guangzhou Puzhiyun Information Technology Co., Ltd.
    Guangzhou Coslan Scientific Instrument Co., Ltd.
    Hainan Dayi Scientific Instrument Co., Ltd.

    Frequently Asked Questions (FAQ)

    Q What is the role of cascade impactors in nasal spray testing?

    Cascade impactors are utilized to capture particles ranging from 0 to 10μm. When combined with a nasal spray expansion chamber, they measure the fine particle dose (FPD) of active pharmaceutical ingredients in nasal sprays and aerosols.

    Q How do I choose between the 1L, 2L, and 5L expansion chambers?

    The choice depends on your specific test requirements: 1L capacity is designed for nasal aerosols to maximize deposition below the top stage; 2L capacity is typical for standard nasal sprays to optimize nebulization; and 5L capacity is reserved for stronger nasal sprays that require more volume to generate the aerosol plume.

    Q Is an expansion chamber required for Nasal Powder FPD testing?

    No, an expansion chamber is not mandatory for Nasal Powder FPD testing. The methodology aligns with Dry Powder Inhaler (DPI) testing, using equivalent test instruments and accessories without the need for a pre-separator.

    Q What parameters does the Inhaler Testing Data Analysis Software calculate?

    The software automatically calculates the cutting particle size based on flow rate inputs. Additionally, it displays critical metrics such as Mass Median Aerodynamic Diameter (MMAD), Geometric Standard Deviation (GSD), and renders particle size distribution fitting curves and scatter diagrams.

    Q Which regulatory standards does this testing methodology comply with?

    The testing framework and instruments align with key global standards, including the FDA Bioavailability and Bioequivalence Studies for Nasal Aerosols and Nasal Sprays (2003), FDA guidelines for Nasal Spray, Inhalation Solution, Suspension & Spray Drug Products (2002), and the European Pharmacopoeia (Ph.Eur. 2021 10.5) for Nasal Preparations.