Request a Quote
Leave Your Message

China Suppliers Factory PM2.5 Online Enrichment System for Real-Time Hazy Atmosphere Extraction and Inhalation Tests

The Slit Impact PM2.5 Online Enrichment System is an advanced solution designed for real-time extraction of hazy outdoor air, specifically focusing on PM2.5 particles. This innovative system concentrates and enriches PM2.5 content in the atmosphere by 6 to 10 times, making it ideal for inhalation exposure tests. As reliable China suppliers and factory manufacturers, we ensure the highest quality standards, providing scientists and researchers with the tools needed for effective air quality assessments. Enhance your research capabilities with our state-of-the-art PM2.5 enrichment system, leading the way in environmental monitoring solutions

    Features

    Real-time online sampling and enrichment of PM2.5 in environment, simulating exposure of animals in high PM2.5 concentration weather.

    Avoid PM2.5 particle contamination and particles physical damage caused by ultrasonic separation, membrane shedding and VOC loss existing in traditional membrane collection methods, retain harmful substances on PM2.5 particles and maintain particle size in the process.

    Particle size concentration 0.1-2.5μm by 6-10 times, output flow rate up to 40-60 L/min.

    Can be connected to rodent whole-body exposure system to perform PM2.5 high-concentration inhalation exposure tests.

    Application

    Relationship studies between environmental particulate pollution and human health effects.

    Animal haze pathogenesis modeling.

    Modeling, pathogenesis and drug intervention mechanism of asthma, airway hyperresponsiveness, chronic obstructive pulmonary disease, pulmonary fibrosis, acute/neonatal respiratory distress syndrome and acute.

    Specification

    6-10 Times
    Concentration Factor
    Up to 40-60L/min
    High Output Flow Rate

    Working Principle

    Air passes through the impact cutter, where particles larger than 2.5μm in diameter are removed, leaving only PM2.5 particles. The air then passes through a two-stage slit virtual impactor, which separates particles below 0.1μm, thereby concentrating the PM2.5 fraction. The concentrated PM2.5 then enters the dilution system, where it is mixed with dilution air before entering the whole-body exposure system.

    1

    The PM2.5 cutting head uses a two-stage cut at 10μm and 2.5μm to remove particles larger than these respective sizes from the air, ensuring effective cut-off performance.

    2

    The system employs a slit-type virtual impactor, which effectively ensures cut-off performance while minimizing particle loss.

    Components

    Impactor cutter system
    First-stage slit virtual impactor system
    Second-stage slit virtual impactor system
    Flow distribution system
    High-flow oil-free vacuum pump
    Noise reduction system for the high-flow oil-free vacuum pump
    Vortex blower
    Noise reduction system for the vortex blower
    Flow control system
    Overall support frame / support structure
    Dedicated adapter for the whole-body exposure system
    Differential pressure monitoring system
    Temperature and humidity monitor
    PM2.5 monitor

    Standards

    HJ 93-2013 Specifications and test procedures for PM10 and PM2.5 sampler

    HJ/T194-2005 Manual methods for ambient air quality monitoring

    Frequently Asked Questions

    How does the system enrich PM2.5 without damaging the particles?
    The system avoids traditional membrane collection methods, which often cause particle contamination and physical damage through ultrasonic separation, membrane shedding, and VOC loss. Instead, it retains harmful substances directly on the PM2.5 particles and maintains their original size structure throughout the process.
    What is the concentration performance and flow rate of this system?
    The system concentrates environmental PM2.5 particles (size range 0.1-2.5μm) by 6 to 10 times, delivering a high output flow rate of up to 40-60 L/min.
    Can this system be integrated with animal exposure chambers?
    Yes, the system is equipped with a dedicated adapter designed specifically to connect with rodent whole-body exposure systems, allowing for high-concentration PM2.5 inhalation exposure testing.
    How does the virtual impactor ensure precise particle cutting?
    The PM2.5 cutting head uses a two-stage cut at 10μm and 2.5μm to filter out larger particles. The system then utilizes a slit-type virtual impactor to separate particles below 0.1μm, ensuring accurate cut-off performance while minimizing particle loss.
    What testing and monitoring standards does this equipment comply with?
    The system complies with standard HJ 93-2013 (Specifications and test procedures for PM10 and PM2.5 samplers) and HJ/T194-2005 (Manual methods for ambient air quality monitoring).
    Are there built-in noise reduction measures for the high-flow pumps?
    Yes, the system includes dedicated noise reduction systems for both the high-flow oil-free vacuum pump and the vortex blower to ensure a quieter laboratory environment.

    Make An AppointmentLEAVE YOUR MESSAGE