Request a Quote
Leave Your Message

China Suppliers Factory Slit Impact PM2.5 Online Enrichment System for Real-Time Air Quality Testing

The Slit Impact PM2.5 Online Enrichment System is an innovative solution designed for real-time extraction of hazy atmospheric particles from outdoor environments. This system effectively concentrates and enriches PM2.5 levels, amplifying them by 6-10 times, making it ideal for inhalation exposure tests. As a leading manufacturer and supplier in China, our factory is dedicated to providing high-quality equipment that meets the needs of researchers and organizations focused on air quality and health studies. Trust our expertise to enhance your PM2.5 testing capabilities today

    Features

    • Real-time online sampling and enrichment of PM2.5 in environment, simulating exposure of animals in high PM2.5 concentration weather.
    • Avoid PM2.5 particle contamination and particles physical damage caused by ultrasonic separation, membrane shedding and VOC loss existing in traditional membrane collection methods, retain harmful substances on PM2.5 particles and maintain particle size in the process.
    • Particle size concentration 0.1-2.5μm by 6-10 times, output flow rate up to 40-60 L/min.
    • Can be connected to rodent whole-body exposure system to perform PM2.5 high-concentration inhalation exposure tests.

    Application

    • Relationship studies between environmental particulate pollution and human health effects.
    • Animal haze pathogenesis modeling.
    • Modeling, pathogenesis and drug intervention mechanism of asthma, airway hyperresponsiveness, chronic obstructive pulmonary disease, pulmonary fibrosis, acute/neonatal respiratory distress syndrome and acute.

    Specification

    Concentration Performance
    6-10 concentration times.
    Output Flow Rate
    High output flow: up to 40-60L/min.

    Working Principle

    Air passes through the impact cutter, where particles larger than 2.5μm in diameter are removed, leaving only PM2.5 particles. The air then passes through a two-stage slit virtual impactor, which separates particles below 0.1μm, thereby concentrating the PM2.5 fraction. The concentrated PM2.5 then enters the dilution system, where it is mixed with dilution air before entering the whole-body exposure system.

    1
    The PM2.5 cutting head uses a two-stage cut at 10μm and 2.5μm to remove particles larger than these respective sizes from the air, ensuring effective cut-off performance.
    2
    The system employs a slit-type virtual impactor, which effectively ensures cut-off performance while minimizing particle loss.

    Components

    The system is composed of the following components:

    Impactor cutter system
    First-stage slit virtual impactor system
    Second-stage slit virtual impactor system
    Flow distribution system
    High-flow oil-free vacuum pump
    Noise reduction system for vacuum pump
    Vortex blower
    Noise reduction system for vortex blower
    Flow control system
    Overall support frame / structure
    Adapter for whole-body exposure system
    Differential pressure monitoring system
    Temperature and humidity monitor
    PM2.5 monitor

    Standards

    HJ 93-2013 Specifications and test procedures for PM10 and PM2.5 sampler
    HJ/T194-2005 Manual methods for ambient air quality monitoring

    Frequently Asked Questions

    How does the system enrich PM2.5 particles?

    The system utilizes an impact cutter to remove particles larger than 2.5μm, followed by a two-stage slit virtual impactor that separates particles below 0.1μm. This process effectively concentrates the target PM2.5 fraction by 6-10 times.

    What is the benefit of online real-time sampling compared to traditional membrane collection?

    Unlike traditional membrane collection, which can cause particle contamination and physical damage due to ultrasonic separation, membrane shedding, and VOC loss, this system retains harmful substances on the PM2.5 particles and maintains their original size distribution.

    Can this concentrator be integrated with animal exposure systems?

    Yes, it is designed with a dedicated adapter to connect directly to rodent whole-body exposure systems, enabling high-concentration PM2.5 inhalation exposure tests.

    What are the flow rate specifications of this system?

    The system delivers a high output flow rate of up to 40-60 L/min, ensuring sufficient air supply for animal exposure modeling.

    What regulatory standards does the equipment comply with?

    The system complies with HJ 93-2013 (Specifications and test procedures for PM10 and PM2.5 samplers) and HJ/T194-2005 (Manual methods for ambient air quality monitoring).

    Make An AppointmentLEAVE YOUR MESSAGE