China Suppliers Factory Slit Impact PM2.5 Online Enrichment System for Real-Time Air Quality Testing
Features
- Real-time online sampling and enrichment of PM2.5 in environment, simulating exposure of animals in high PM2.5 concentration weather.
- Avoid PM2.5 particle contamination and particles physical damage caused by ultrasonic separation, membrane shedding and VOC loss existing in traditional membrane collection methods, retain harmful substances on PM2.5 particles and maintain particle size in the process.
- Particle size concentration 0.1-2.5μm by 6-10 times, output flow rate up to 40-60 L/min.
- Can be connected to rodent whole-body exposure system to perform PM2.5 high-concentration inhalation exposure tests.
Application
- Relationship studies between environmental particulate pollution and human health effects.
- Animal haze pathogenesis modeling.
- Modeling, pathogenesis and drug intervention mechanism of asthma, airway hyperresponsiveness, chronic obstructive pulmonary disease, pulmonary fibrosis, acute/neonatal respiratory distress syndrome and acute.
Specification
Working Principle
Air passes through the impact cutter, where particles larger than 2.5μm in diameter are removed, leaving only PM2.5 particles. The air then passes through a two-stage slit virtual impactor, which separates particles below 0.1μm, thereby concentrating the PM2.5 fraction. The concentrated PM2.5 then enters the dilution system, where it is mixed with dilution air before entering the whole-body exposure system.
Components
The system is composed of the following components:
Standards
Frequently Asked Questions
How does the system enrich PM2.5 particles?
The system utilizes an impact cutter to remove particles larger than 2.5μm, followed by a two-stage slit virtual impactor that separates particles below 0.1μm. This process effectively concentrates the target PM2.5 fraction by 6-10 times.
What is the benefit of online real-time sampling compared to traditional membrane collection?
Unlike traditional membrane collection, which can cause particle contamination and physical damage due to ultrasonic separation, membrane shedding, and VOC loss, this system retains harmful substances on the PM2.5 particles and maintains their original size distribution.
Can this concentrator be integrated with animal exposure systems?
Yes, it is designed with a dedicated adapter to connect directly to rodent whole-body exposure systems, enabling high-concentration PM2.5 inhalation exposure tests.
What are the flow rate specifications of this system?
The system delivers a high output flow rate of up to 40-60 L/min, ensuring sufficient air supply for animal exposure modeling.
What regulatory standards does the equipment comply with?
The system complies with HJ 93-2013 (Specifications and test procedures for PM10 and PM2.5 samplers) and HJ/T194-2005 (Manual methods for ambient air quality monitoring).