China Suppliers Factory Slit Impact PM2.5 Online Enrichment System for Real-Time Hazy Atmosphere Extraction

The Slit Impact PM2.5 Online Enrichment System is an advanced solution designed to extract hazy outdoor atmospheres in real-time. This innovative system concentrates and enriches PM2.5 content by 6-10 times, making it ideal for inhalation exposure testing. As a leading supplier in China, our factory produces high-quality equipment tailored for environmental monitoring and research. Experience the efficiency of our PM2.5 enrichment technology, designed to meet the needs of laboratories and researchers across various industries

    Features

    Real-time online sampling and enrichment of PM2.5 in environment, simulating exposure of animals in high PM2.5 concentration weather.

    Avoid PM2.5 particle contamination and particles physical damage caused by ultrasonic separation, membrane shedding and VOC loss existing in traditional membrane collection methods, retain harmful substances on PM2.5 particles and maintain particle size in the process.

    Particle size concentration 0.1-2.5m by 6-10 times, output flow rate up to 40-60 L/min.

    Can be connected to rodent whole-body exposure system to perform PM2.5 high-concentration inhalation exposure tests.

    Application

    • Relationship studies between environmental particulate pollution and human health effects.
    • Animal haze pathogenesis modeling.
    • Modeling, pathogenesis and drug intervention mechanism of asthma, airway hyperresponsiveness, chronic obstructive pulmonary disease, pulmonary fibrosis, acute/neonatal respiratory distress syndrome and acute.

    Specification

    Concentration Times
    6-10 times
    Output Flow Rate
    Up to 40-60L/min (High Output)

    Working Principle

    Air passes through the impact cutter, where particles larger than 2.5μm in diameter are removed, leaving only PM2.5 particles. The air then passes through a two-stage slit virtual impactor, which separates particles below 0.1μm, thereby concentrating the PM2.5 fraction. The concentrated PM2.5 then enters the dilution system, where it is mixed with dilution air before entering the whole-body exposure system.
    1

    The PM2.5 cutting head uses a two-stage cut at 10μm and 2.5μm to remove particles larger than these respective sizes from the air, ensuring effective cut-off performance.

    2

    The system employs a slit-type virtual impactor, which effectively ensures cut-off performance while minimizing particle loss.

    Components

    The system is composed of the following components:
    · Impactor cutter system
    · First-stage slit virtual impactor system
    · Second-stage slit virtual impactor system
    · Flow distribution system
    · High-flow oil-free vacuum pump
    · Noise reduction system for the high-flow oil-free vacuum pump
    · Vortex blower
    · Noise reduction system for the vortex blower
    · Flow control system
    · Overall support frame / support structure
    · Dedicated adapter for the whole-body exposure system
    · Differential pressure monitoring system
    · Temperature and humidity monitor
    · PM2.5 monitor

    Standards

    Standard

    HJ 93-2013 Specifications and test procedures for PM10 and PM2.5 sampler

    Standard

    HJ/T194-2005 Manual methods for ambient air quality monitoring

    Frequently Asked Questions

    How does the system enrich PM2.5 particles for exposure tests?
    The system achieves real-time online sampling and enrichment of environmental PM2.5. By concentrating particle sizes of 0.1-2.5m by 6-10 times, it successfully simulates animal exposure in high-concentration PM2.5 weather conditions.
    Does this method cause damage to the PM2.5 particles during collection?
    No. Unlike traditional membrane collection methods, this system avoids particle contamination and physical damage caused by ultrasonic separation, membrane shedding, and VOC loss. It retains harmful substances on the PM2.5 particles and maintains their original particle size.
    What is the maximum flow rate and concentration ratio of this system?
    The system features a particle size concentration of 6-10 times for particles in the 0.1-2.5m range, with a high output flow rate reaching up to 40-60 L/min.
    Can this equipment be integrated with rodent exposure chambers?
    Yes, the system can be directly connected to a rodent whole-body exposure system to carry out PM2.5 high-concentration inhalation exposure biological tests.
    What is the working principle of the virtual impactor in this system?
    Air first passes through an impact cutter to remove particles larger than 2.5μm. It then goes through a two-stage slit virtual impactor that separates particles below 0.1μm to concentrate the PM2.5. Finally, the concentrated PM2.5 is mixed with dilution air before entering the exposure system.
    Which environmental monitoring standards does this system comply with?
    The system complies with standard HJ 93-2013 (Specifications and test procedures for PM10 and PM2.5 sampler) and HJ/T194-2005 (Manual methods for ambient air quality monitoring).

    Make An AppointmentLEAVE YOUR MESSAGE