China Suppliers Factory Slit Impact PM2.5 Online Enrichment System for Real-Time Hazy Atmosphere Testing
Features
Real-Time Sampling
Enables real-time online sampling and enrichment of PM2.5 in the environment, simulating animal exposure under high PM2.5 concentration weather conditions.
Particle Integrity
Avoids PM2.5 contamination and physical damage caused by ultrasonic separation, membrane shedding, and VOC loss typical in traditional membrane collection, retaining harmful substances and maintaining original particle size.
High Concentration
Concentrates particle sizes from 0.1 to 2.5μm by 6 to 10 times, delivering an output flow rate up to 40-60 L/min.
System Integration
Can be seamlessly connected to rodent whole-body exposure systems for conducting high-concentration PM2.5 inhalation exposure tests.
Application
- Relationship studies between environmental particulate pollution and human health effects.
- Animal haze pathogenesis modeling.
- Modeling, pathogenesis, and drug intervention mechanisms for asthma, airway hyperresponsiveness, chronic obstructive pulmonary disease (COPD), pulmonary fibrosis, acute/neonatal respiratory distress syndrome, and acute lung injury.
Specification
Working Principle
Air passes through the impact cutter, where particles larger than 2.5μm in diameter are removed, leaving only PM2.5 particles. The air then passes through a two-stage slit virtual impactor, which separates particles below 0.1μm, thereby concentrating the PM2.5 fraction. The concentrated PM2.5 then enters the dilution system, where it is mixed with dilution air before entering the whole-body exposure system.
The PM2.5 cutting head uses a two-stage cut at 10μm and 2.5μm to remove particles larger than these respective sizes from the air, ensuring effective cut-off performance.
The system employs a slit-type virtual impactor, which effectively ensures cut-off performance while minimizing particle loss.
Components
Standards
- HJ 93-2013: Specifications and test procedures for PM10 and PM2.5 sampler.
- HJ/T194-2005: Manual methods for ambient air quality monitoring.
Frequently Asked Questions
What is the concentration performance of this PM2.5 system?
The system can enrich and concentrate PM2.5 particles (size range 0.1 to 2.5μm) by 6 to 10 times, providing a stable high-flow output up to 40-60 L/min.
How does this system preserve the integrity of PM2.5 particles?
By bypassing traditional membrane collection methods, it avoids particle damage from ultrasonic separation, membrane shedding, and volatile organic compound (VOC) loss. This ensures that harmful substances on the particles are fully retained and original particle sizes are maintained.
Can this concentrator be paired with other research systems?
Yes, it is specifically designed to connect to rodent whole-body exposure systems, allowing researchers to perform targeted high-concentration inhalation exposure tests.
What is the role of the two-stage slit virtual impactor?
The slit-type virtual impactor separates particles below 0.1μm and concentrates the targeted PM2.5 fraction while effectively minimizing overall particle loss and ensuring optimal cut-off performance.
What environmental testing standards does this equipment comply with?
The system is designed in compliance with Chinese environmental protection standards HJ 93-2013 (Specifications and test procedures for PM10 and PM2.5 samplers) and HJ/T194-2005 (Manual methods for ambient air quality monitoring).