China Suppliers for Canine Nose-only Exposure System | Factory for Inhalation Testing of Gases and Aerosols

The Canine Nose-only Exposure System is designed for comprehensive testing of canine exposure to various agents, including gases, vapors, liquid aerosols, solid aerosols, and nanoparticle aerosols. This state-of-the-art system is perfect for conducting acute, subacute, chronic, and sub-chronic inhalation tests. As one of the leading suppliers and factory in China specializing in advanced exposure systems, we ensure the highest quality and reliability for your research needs. Optimize your testing methodologies with our innovative solution tailored for effective inhalation studies

    Features

    Adopt stainless steel double static pressure chamber structure, it can perform inhalation tests for 6-10 canines simultaneously.

    The uniformity and stability deviation of each exposure port's mass concentration during tests for gas is within ±8%, for liquid aerosol is within ±10%, while for dust aerosol is within ±20%, which conforms to technical requirements of OECD guidelines.

    Achieve dynamic monitoring of the test article mass concentration, in compliance with OECD TG 403 and OECD TG 436.

    Enable real-time online detection of aerosol particle size distribution and manual particle size analysis (optional).

    Waste gas can fully meet Safety Emission Standards after treatment.

    The unique structural and air pressure control of exposure system ensures tight protection. Protection alarm is effective against abnormal temp, abnormal pressure difference and gas leakage.

    Unique human machine interface (HMI) for intuitive and convenient operation. Powerful software and hardware supporting system; the software complies with GLP requirements.

    Application

    Drug Safety Evaluation
    Inhalation Immunity and Environment Assessment
    Respiratory Disease Modeling and Drug Efficacy Evaluation
    Hazard Assessment and Radioactive Substances Protection
    Aerospace Medicine

    Components

    1. Aerosol Dilution Unit

    Vortex mixed dilution by adopting uninterruptible cone gapless slit technology.

    2. Aerosol Gas Supply and Extraction Static Pressure Chamber

    Dilute aerosols and stabilize at the required concentration rapidly and non-destructively by unique patented cone gapless slit technology. Main structure is made of SS316L with excellent performances such as high temp resistance, corrosion resistance, fire and explosion-proof, easy to clean, etc.

    2Components
    3. Canine Fixed Car

    Main structure is welded with high quality stainless steel, which is corrosion resistant and easy to clean. Animals can be flexibly fixed, which both meet animal standing/ leaning changing and can prevent violent movements affecting test accuracy. One fixed car for one dog. Animal support plate and fixed part can be adjusted to meet requirements of different canine animal tests.

    3.Canine Fixed Car
    4. For nose-only inhalation exposure

    of awake canine animals. Suitable mouth and nose mask with good fitness. The contact part is made of comfortable soft silicone.

    4.Canine Fixed Car
    5. Liquid Aerosol Generator
    • Aerosol particle size distribution is MMAD1-3μm, GSD1.5-3 which meets 403 Acute Inhalation Toxicity and other standards.
    • Atomized by compressed air heatlessly, liquid samples can be generated into even and stable aerosol;
    • Applicable to various water-soluble and oil-soluble liquid samples and suspensions with some stable fine particles;
    • Applicable to aerosol generating from rare samples in large dose;
    • Applicable to microbial aerosol generation with minimal damage on microorganisms, and can be applied to animal inhalation infection models and related research;
    • Made of medical-grade SS316L, Teflon and high borosilicate glass, which are anti-corrosion and can be autoclaved.
    Model Nozzle number Rated gas flow
    HRH-WAG1 1 2L/min
    HRH-WAG3 3 6L/min
    HRH-WAG6 6 12L/min
    HRH-WAG1M Micro liquid 1 nozzle 2L/min
    HRH-WAG3M Micro liquid 3 nozzles 6L/min
    HRH-WAG6M Micro liquid 6 nozzles 12L/min
    HRH-WAG12 12 24L/min
    HRH-WAG24 24 48L/min
    5.Made of medical-grade SS316L, Te
    6. Dust Aerosol Generator
    • MMAD (Mass Median Aerodynamic Diameter): 1-4μm (ISO 12103-A2 Fine Test Dust), GSD1.5-3.
    • Offer report copy of dust particles aerodynamic particle size distribution generated by dust aerosol generator, issued by Academy of Military Medical Sciences;
    • Working method: gradual expansion by rotating divergent brush;
    • Particles: non-sticky powder or dust;
    • Computer control: independent control system with real-time display of parameters, including gas source pressure, gas flow, powder mass flow, theoretical concentration, remaining working time and feeding speed, etc.;
    • Dust loading: 10ml, 40ml, 300ml optional;
    • Particle size: 0.1~20μm;
    • Mass flow: 10~20000mg /min adjustable;
    • Aerosol flow: 5~100L /min adjustable;
    • Brush rotating speed: 600~1000rpm adjustable;
    • Delivery period: 10min~400h;
    • Dust residual: absolute value measured by electronic ruler;
    • Flow monitor: monitor and display automatically;
    • Dust mass concentration: calculate and display automatically;
    • Protection alarm: Six-fold intelligent detection and protection alarm.
    6.6.Dust Aerosol Generator
    7. Membrane Weighing Sampler

    Used to sample dry powder aerosol and non-volatile liquid aerosol by filtered weighing method. Timed auto-sampling technology can be realized by host control with sampling flow rate 0.1~5L/min, accuracy +1.0%F.S, time 0~6h adjustable.

    13.Membrane Weighing Sampler
    8. Porous Glass Sampler

    Three-stage porous glass adsorptive sampler is used for sampling gases with absorbable properties and volatile liquid aerosol. Timed auto-sampling technology can be realized by host control with sampling flow rate 0.1~ 1L/min, accuracy ±1.0%F.S, time 0 ~ 6h adjustable. Each group of three-stage sampling tube can be used independently or in series.

    14 Porous Glass Sampler
    9. Aerodynamic Particle Sizer
    • It is a low-flow particle size analysis sampler with inertial impact principle, used for stage sampling and weighing of aerosol particles and then calculating parameters such as MMAD and GSD, etc.;
    • Sampling flow rate 0.5L/min is ideal for particle size analysis in animal exposure tests.
    • The sampler is divided into 7 stages + membrane stage, cutting particle size of each stage as below:
    Stage Cutting Size (μm)
    1 5.1
    2 3.1
    3 1.9
    4 1.2
    5 0.77
    6 0.5
    7 0.33
    17. Aerodynamic Particle Sizer
    10. Control Cabinet

    Collect real-time parameters such as temp, humidity, pressure difference, oxygen concentration, carbon dioxide and aerosol concentration inside cabinet; Control 4-way flow controllers of aerosol generation, dilution, sampling and total gas extraction volume; Control automatic devices such as gas extraction pump.

    10.control
    11. Host Software

    With functions of user classified management, the software can perform tests overall control, parameter setting, real-time monitoring and recording for environmental parameters during tests, real-time alarm and recording of abnormalities; Various test data storage and access, automatically issue reports post-test, etc.

    11. Host Software 11. Host Software 11. Host Software 11. Host Software

    Specification

    Product Model Configuration
    Canine Nose-only Exposure System HRH-LMNE1168 Standard
    HRH-LMNE1198 Premium

    Standards

    OECD Guidelines

    • OECD TG 403 Acute Inhalation Toxicity (2009).
    • OECD TG 436 Acute Inhalation Toxicity. Acute Toxic Class Method (2009).
    • OECD TG 412 28d Sub-acute inhalation (2018).
    • OECD TG 413 90d Sub-chronic inhalation (2018).

    Pesticide Registration Standards

    • GB /T 15670.6 ~2017 Toxicological test methods for pesticides registration—Part 6: Acute inhalation toxicity test.
    • GB /T 15670.12 ~ 2017 Toxicological test methods for pesticides registration—Part 12: Short-term repeated dose 28-day inhalation toxicity study.
    • GB /T 15670.13 ~2017 Toxicological test methods for pesticides registration—Part 13: Subchronic toxicity study.
    • GB /T 15670.26 ~ 2017 Toxicological test methods for pesticides registration—Part 26: Chronic toxicity study.

    New Chemical Substances Registration

    • 403 Acute Inhalation Toxicity(2013, 2nd edition).
    • 436 Acute Inhalation Toxicity Test: Acute Toxic Class Method(2013, 2nd edition).
    • 412 Sub-acute inhalation:28-days test(2013, 2nd edition).
    • 413 Sub-chronic inhalation:90-days test(2013, 2nd edition).

    Frequently Asked Questions

    Q1. How many animals can the Canine Nose-only Exposure System test simultaneously?
    The system adopts a stainless steel double static pressure chamber structure, enabling it to perform inhalation tests for 6 to 10 canines simultaneously.
    Q2. What are the mass concentration deviations for different exposure tests?
    The stability and uniformity deviation of each exposure port's mass concentration conforms to OECD guidelines: within ±8% for gas, within ±10% for liquid aerosol, and within ±20% for dust aerosol.
    Q3. Does the system support real-time monitoring of particle size distribution?
    Yes, the system enables real-time online detection of aerosol particle size distribution, and it also offers an optional module for manual particle size analysis.
    Q4. What safety alarms and protection features are integrated into the system?
    The exposure system features unique structural and air pressure controls to ensure tight protection. The system is equipped with effective protection alarms against abnormal temperature, abnormal pressure difference, and gas leakage.
    Q5. Does the software of the control system meet regulatory standards?
    Yes, the host software is built on a powerful software and hardware supporting system that complies with GLP (Good Laboratory Practice) requirements, featuring user classified management, real-time monitoring, test data storage, and automated post-test report generation.
    Q6. Which regulatory standards and guidelines does this exposure system conform to?
    The system fully complies with OECD guidelines (including TG 403, TG 436, TG 412, and TG 413), Pesticide Registration Standards (GB/T 15670 series), and the Registration of New Chemical Substances by the Ministry of Ecology and Environment.