Request a Quote
Leave Your Message

China Suppliers - Multi-Concentration Nose-Only Inhalation Exposure System for Rodents | Factory Quality Assurance

The Multi-Concentration Nose-Only Inhalation Exposure System for Rodents is a cutting-edge solution designed for conducting precise nose-only inhalation toxicity tests. This system efficiently handles various bioaerosols, chemical aerosols, and smoke with multiple concentrations, ensuring consistent inhalation doses within the same test group. With advanced capabilities for online monitoring of aerosol concentration and real-time sampling, this system achieves unparalleled exposure uniformity and stability, powered by a high-precision control system. As a leading manufacturer in China, we cater to laboratories and researchers by providing superior products that meet the highest industry standards. Connect with us to source from reputable suppliers and experience the excellence of our factory-made inhalation systems

    Features

    The nose only exposure chamber is constructed as a double core stainless steel structure, with positive pressure in the inner core and negative pressure in the outer core, ensuring that the exhaust gas exhaled by the animals does not contaminate or dilute the aerosol.

    In a single experiment, either single concentration or multi concentration mode can be selected to perform aerosol inhalation exposure studies.

    During the experiment, the uniformity and stability error of the aerosol mass concentration at each exposure port is within ±8% for gaseous test substances, within ±10% for liquid aerosols, and within ±20% for dust aerosols. These values comply with the OECD inhalation guidance documents and the national technical standards for toxicity testing of pesticides and chemicals.

    The negative containment system ensures the safety of laboratory personnel.

    The exhaust gas generated during the experiment is treated by a filtration system and fully meets national safety emission standards.

    The software features user level management, audit trail, data unerasable and undeletable, electronic signatures, etc., meeting GLP requirements.

    With the optional online pulmonary function monitoring system, the inhalation exposure experiment can be automatically terminated based on the theoretical inhaled dose.

    Application

    Drug Safety Evaluation.
    Respiratory Disease Modeling and Drug Efficacy Evaluation.
    Chemicals and Pesticide Safety Evaluation.
    Hazard Assessment and Radioactive Substances Protection.
    Inhalation Immunity and Environment Assessment.
    Aerospace Medicine.

    Standards

    OECD Guidelines
    • 1 OECD TG 403 Acute Inhalation Toxicity (2009).
    • 2 OECD TG 436 Acute Inhalation Toxicity. Acute Toxic Class Method (2009).
    • 3 OECD TG 412 28d Sub-acute inhalation (2018).
    • 4 OECD TG 413 90d Sub-chronic inhalation (2018).
    Pesticide Registration Standards
    • 1 GB /T 15670.6 ~2017 Toxicological test methods for pesticides registration—Part 6: Acute inhalation toxicity test.
    • 2 GB /T 15670.12 ~ 2017 Toxicological test methods for pesticides registration—Part 12: Short-term repeated dose 28-day inhalation toxicity study.
    • 3 GB /T 15670.13 ~2017 Toxicological test methods for pesticides registration—Part 13: Subchronic toxicity study.
    • 4 GB /T 15670.26 ~ 2017 Toxicological test methods for pesticides registration—Part 26: Chronic toxicity study.
    Registration of New Chemical Substances by Ministry of Ecology and Environment
    • 1 403 Acute Inhalation Toxicity(2013, 2nd edition).
    • 2 436 Acute Inhalation Toxicity Test:Acute Toxic Class Method(2013, 2nd edition).
    • 3 412 Sub-acute inhalation:28-days test(2013, 2nd edition).
    • 4 413 Sub-chronic inhalation:90-days test(2013, 2nd edition).

    Typical Users

    Chinese Academy of Inspection and Quarantine
    China Institute for Radiation Protection
    Naval Medical University
    Kunming Institute of Zoology. CAS
    Zhengzhou National Tobacco Quality Supervision and Inspection Center

    Frequently Asked Questions

    What is the design principle of the nose-only exposure chamber?

    The chamber is built with a double-core stainless steel structure. It utilizes positive pressure in the inner core and negative pressure in the outer core to prevent exhaled gases from contaminating or diluting the aerosol.

    Does the exposure chamber comply with international guidelines?

    Yes, it fully complies with the OECD inhalation guidance documents (such as OECD TG 403, 436, 412, and 413) as well as national technical standards for toxicological testing of pesticides and chemicals.

    How is safety managed for laboratory personnel and the environment?

    Laboratory safety is maintained via a negative containment system. Additionally, all exhaust gas generated during experiments is treated through a dedicated filtration system to meet national safety emission standards.

    Is the system's software compliant with Good Laboratory Practice (GLP)?

    Yes, the software supports GLP requirements by featuring user-level management, audit trails, electronic signatures, and unerasable/undeletable data records.

    Can the system automatically terminate an ongoing experiment?

    Yes, by integrating the optional online pulmonary function monitoring system, the inhalation exposure experiment can be automatically terminated once the theoretical inhaled dose is reached.

    What are the typical applications for this system?

    Typical applications include drug safety evaluation, respiratory disease modeling, chemical and pesticide safety evaluation, hazard and radioactive substance assessment, environmental assessment, and aerospace medicine.

    Make An AppointmentLEAVE YOUR MESSAGE