China Two-fluid Liquid Aerosol Generator Factory - Precision Gas-Liquid Control & Inhalation Compliance Suppliers

Introducing the Two-fluid Liquid Aerosol Generator, a cutting-edge solution designed in China that leverages advanced multi-channel strong vortex atomization technology. This innovative device precisely controls the gas-liquid ratio, ensuring optimal performance. With a built-in particle-size sieving buffer chamber, it effectively achieves an aerosol particle size distribution of MMAD 1-3µm and GSD 1.5-3, making it ideal for inhalation applications. As a leading factory and supplier in the industry, we are committed to delivering high-quality aerosol generation solutions that meet your specific needs

    Features

    • Compared with the traditional aerosol generator, HRH-TAG1 is suitable for viscous or heavy oils which are difficult to be generated.

    • Can be connected to a peristaltic pump to add liquid to meet the long-term experimental needs.

    • Streamlined design particle size sieving buffer chamber is removable and easy to clean.

    • The generated aerosol MMAD 1-3μm, GSD 1.5-3.

    • It can be easily connected with our nose-only exposure system for rodents.

    Application

    Fine atomization of various liquids.
    Requirements of inhalation toxicology and inhalation immunity.
    Applicable to generation of microbial aerosols and studies of animal inhalation infection models.

    It can be applied to inhalation toxicology research, aerobiology, aerosol research, biohazard testing, performance evaluation of filters, inhalation immunization, inhalation therapy, drug research, environmental evaluation, hazard assessment of biology and chemistry, and medical protection. Especially suitable for viscous or heavy oils which are difficult to be generated by traditional generators, also can be used for various water-soluble, oil-soluble and part of the fine particles stabilized suspension and other solutions samples.

    Aerosol Generation

    After connecting the compressed air pipeline and aerosol pipeline, open the compressed air valve, the compressed air inside the two-flow nozzle forms high-speed rotary flow, resulting in a strong vortex circumstance, the liquid sample is pumped in by the peristaltic pump and then dispersed mixed with high-speed spray to form aerosols. Big particles impact to the buffer chamber wall or deposit in the forward process, and discharged through the waste liquid outlet, small particles will be output from the aerosol outlet.

    Specification

    Parameter / Connection Type Specification
    Specification of silicon tube in connection with liquid tube 2mm x 4mm
    Outer diameter of PU tubes in connection with air compressor 4mm x 6mm
    Aerosol outlet specification 16mm x 20mm

    Standards

    • ① OECD TG 403 Acute Inhalation Toxicity (2009).

    • ② OECD TG 436 Acute Inhalation Toxicity. Acute Toxic Class Method (2009).

    • ③ OECD TG 412 28d Sub-acute inhalation (2018).

    • ④ OECD TG 413 90d Sub-chronic inhalation (2018).

    Frequently Asked Questions

    Q What makes the HRH-TAG1 aerosol generator suitable for viscous or heavy oils?
    Unlike traditional aerosol generators, the HRH-TAG1 is specifically engineered to handle viscous or heavy oils that are typically difficult to atomize, utilizing a high-speed rotary two-flow nozzle design to effectively disperse challenging liquid samples.
    Q Can this generator be used for long-term continuous inhalation studies?
    Yes. The HRH-TAG1 can be connected directly to an external peristaltic pump, allowing for continuous liquid replenishment to easily meet the demands of long-term inhalation toxicology and exposure experiments.
    Q What is the particle size distribution of the generated aerosol?
    The generator produces a highly consistent aerosol with a Mass Median Aerodynamic Diameter (MMAD) of 1-3μm and a Geometric Standard Deviation (GSD) of 1.5-3, which is optimal for rodent inhalation studies.
    Q Is the HRH-TAG1 compatible with nose-only exposure systems?
    Yes, it is designed for seamless integration and can be easily connected with our nose-only exposure systems for rodents to facilitate controlled inhalation toxicology research.
    Q Which testing standards does the HRH-TAG1 aerosol generator comply with?
    The generator supports compliance with several international testing guidelines, including OECD TG 403 (Acute Inhalation Toxicity), OECD TG 436 (Acute Toxic Class Method), OECD TG 412 (28d Sub-acute Inhalation), and OECD TG 413 (90d Sub-chronic Inhalation).