Cryogenic liquids, including Liquefied Natural Gas (LNG), Liquid Nitrogen (LN2), Liquid Oxygen (LOX), and Liquid Hydrogen (LH2), are transported at temperatures reaching as low as -253°C. The thermal insulation of these piping systems is paramount to preventing heat ingress, boil-off gas (BOG) accumulation, and catastrophic structural failure. Vacuum-jacketed piping (VJP) is the industry standard for transporting these fluids, featuring an inner line carrying the cryogenic liquid and an outer protective jacket maintaining a high vacuum. Any breach in the vacuum integrity or containment shell immediately compromises thermal efficiency, leading to rapid pressurization, ice formation, and safety hazards.
In this context, detecting micro-leaks, validating secondary containment structures, and testing purge/ventilation pathways are essential maintenance protocols. Cigarette smoke testing—specifically using controlled, high-density aerosol generation systems—has emerged as a vital diagnostic method. It allows engineers to visually trace flow patterns, locate micro-fractures in outer sheaths, and ensure that safety ventilation systems effectively disperse leaked gases before they reach explosive or asphyxiating concentrations.
Did You Know? The sub-micron size of simulated cigarette smoke particles (0.1 to 1.0 microns) mimics the dispersion behavior of volatile cryogenic gases, making it an excellent tracer for airflow visualization and micro-leak path detection in complex piping networks.
Traditional leak detection methods, such as helium mass spectrometry, are highly precise but fail to provide visual data regarding gas dispersion and secondary containment flow dynamics. Cigarette smoke testing bridges this gap by generating highly visible, stable aerosols that behave dynamically like gases. The key advantages include:
A. Vacuum Jacket Outer Shell Integrity: In large-scale air separation plants and LNG terminals, vacuum-jacketed pipes span kilometers. A breach in the outer jacket allows ambient air to enter the vacuum space, where it immediately condenses and freezes against the cold inner pipe. During shut-down or maintenance cycles, this ice melts, creating high-pressure pockets. By introducing tracer aerosols into the jacket space during low-pressure nitrogen purges, technicians can visually detect escaping smoke at the exact point of outer shell failure.
B. Ventilation and Purge System Verification: Cryogenic storage facilities utilize forced ventilation to prevent the accumulation of hazardous gases (like nitrogen or hydrogen) in confined pipe galleries. Using intelligent smoke generators, safety inspectors can simulate a massive gas release. The visual dispersion of the smoke confirms whether the ventilation intake and exhaust configurations are correctly positioned to eliminate dead zones where gas could pool.
C. Aerospace Launch Pad Piping Protection: Launch complexes handling liquid oxygen and liquid hydrogen require flawless piping insulation. Smoke testing is deployed during pre-launch checkout phases to verify the integrity of containment shrouds surrounding high-pressure cryogenic valves, ensuring that any purge nitrogen is flowing smoothly without turbulence or stagnation.
The global shift toward green energy has accelerated the adoption of Liquid Hydrogen (LH2) and LNG, driving unprecedented demand for cryogenic piping safety instrumentation. The market is transitioning from manual, uncontrolled smoke sticks to automated, intelligent aerosol generation systems. Modern systems must offer precise control over smoke density, particle size distribution, and flow rate to ensure repeatable testing parameters that comply with strict industrial safety standards (such as ASME B31.3 for process piping and NFPA 59A for LNG facilities).
Furthermore, integration with digital imaging and AI-driven optical sensors allows for automated leak detection. By analyzing video feeds of smoke tests, AI algorithms can identify minor wisps of smoke that might be missed by the human eye, quantifying the leak severity and mapping it directly onto the facility's digital twin.
Beijing Huironghe Technology Co., Ltd., (overseas brand "HRHINS") founded in 2010 with a registered capital of 10 million yuan, is located in the Beijing Economic-Technological Development Area. The company specializes in the R&D, production, sales, and technical services for inhalation toxicity, genetic toxicity, inhaler testing, aerosol detection, and lab automation systems.
HRHINS has been recognized as a National High-tech Enterprise and designated as a Beijing Municipal Corporate Science and Technology R&D Institution. Additionally, it has received honors such as being a Beijing "Specialized, Refined, Unique, and Innovative" SME, a China Manufacturing Champion Enterprise, and a Beijing Intellectual Property Demonstration Enterprise.
Further accolades include being named a National Intellectual Property Advantage Enterprise in 2019, a National "Little Giant" SME (the first in the aerosol scientific instrument field) in 2022, and a recipient of the Second Prize in Scientific and Technological Progress from the Tianjin Municipal Government in 2022.
The company occupies over 3000sqm of offices, R&D center and workshops.
HRHINS holds certifications for the ISO 9001:2015 Quality Management System, ISO 14001:2015 Environmental Management System, ISO 45001:2018 Occupational Health and Safety Management System, and GB/T 29490-2013 Intellectual Property Management System.
In 2018, HRHINS supported the establishment of the Respiratory Toxicology Committee of the Chinese Society of Toxicology and became its founding sponsor. The company also gained council membership in several prestigious organizations, including the Chinese Society of Toxicology, the Chinese Environmental Mutagen Society, and the Zhongguancun New Bio-pharmaceutical Industry Alliance.
HRHINS has developed over 60 innovative instruments, including aerosol generators, inhalation systems, fully automated QuEChERS system, multi-stage cascade impactor, and breathing simulator, etc.
The aerosol toxicity instrument line offers a complete suite for studies involving rats, mice, guinea pigs, ferrets, rabbits, dogs, and monkeys. Supported exposure methods are equally comprehensive, covering nose-head, whole-body, airborne infection, and in vitro cell culture exposures.
Crucially, all products—from aerosol generation and detection to sampling and system control—are based on independent intellectual property. These solutions are widely employed by GLP laboratories, safety assessment centers, universities, research institutions, and hospital respiratory departments.