Request a Quote
Leave Your Message

Dynamic Whole-body Exposure System for Rodents | China Suppliers & Factory for Inhalation Testing Equipment

The Dynamic Whole-body Exposure System for Rodents is an advanced solution designed for conducting inhalation exposure tests on various rodent species, including rats, mice, and guinea pigs. This innovative system allows for precise exposure to gases, vapors, liquid aerosols, solid aerosols, and nanoparticle aerosols, making it ideal for researchers exploring respiratory effects and toxicology studies. As a leading supplier in China, our factory ensures high-quality manufacturing standards and reliable performance, catering to the needs of laboratories and research institutions worldwide. Optimize your inhalation studies with the best dynamic exposure system from trusted suppliers in China.

    Application

    Drug Safety Evaluation

    Chemicals and Pesticide Safety Evaluation

    Inhalation Immunity and Environment Assessment

    Respiratory Disease Modeling and Drug Efficacy Evaluation

    Hazard Assessment and Radioactive Substances Protection

    Aerospace Medicine

    Features

    Feature 01

    1. The uniformity and stability deviation of animal respiratory tract for gas is within ±8%, for liquid aerosol is within ±10%, while for dust aerosol is within ±20%, which conforms to technical requirements of OECD guidelines.

    Feature 02

    2. Aerosol particle size distribution is MMAD 1-3μm, GSD 1.5-3.

    Feature 03

    3. The temp, humidity, oxygen and carbon dioxide concentration of whole body exposure chamber during test meet requirements of inhalation guidelines.

    Feature 04

    4. One cage for one rat inhalation exposure can perform 20-80 rats test simultaneously.

    Feature 05

    5. Real-time monitor temp, humidity, pressure difference, oxygen and carbon dioxide concentration of exposure chamber during tests. Parameters can be controlled according to requirements of laboratory, e.g., air inlet flow, dilution flow, sampling flow, exhaust flow, exposure time, remaining time, etc.

    Standards

    OECD Guidelines
    • ① OECD TG 403 Acute Inhalation Toxicity (2009).
    • ② OECD TG 436 Acute Inhalation Toxicity. Acute Toxic Class Method (2009).
    • ③ OECD TG 412 28d Sub-acute inhalation (2018).
    • ④ OECD TG 413 90d Sub-chronic inhalation (2018).
    Pesticide Registration Standards
    • ① GB /T 15670.6 ~2017 Toxicological test methods for pesticides registration—Part 6: Acute inhalation toxicity test.
    • ② GB /T 15670.12 ~ 2017 Toxicological test methods for pesticides registration—Part 12: Short-term repeated dose 28-day inhalation toxicity study.
    • ③ GB /T 15670.13 ~2017 Toxicological test methods for pesticides registration—Part 13: Subchronic toxicity study.
    • ④ GB /T 15670.26 ~ 2017 Toxicological test methods for pesticides registration—Part 26: Chronic toxicity study.
    Registration of New Chemical Substances by Ministry of Ecology and Environment
    • ① 403 Acute Inhalation Toxicity (2013, 2nd edition).
    • ② 436 Acute Inhalation Toxicity Test: Acute Toxic Class Method (2013, 2nd edition).
    • ③ 412 Sub-acute inhalation:28-days test (2013, 2nd edition).
    • ④ 413 Sub-chronic inhalation:90-days test (2013, 2nd edition).
    OECD FDA GLP

    Typical Users

    Institute of Environmental and Occupational Medicine, Academy of Military Medical Sciences Capital Medical University
    China Institute for Radiation Protection Guangxi University of Science and Technology
    Chinese Center for Disease Control and Prevention North China University of Science and Technology
    Institute of Laboratory Animals Science, CAMS & PUMC Shaanxi University of Chinese Medicine
    Jiangsu Provincial Center for Disease Control and Prevention Hebei Medical University
    Medical Research Center, Second Artillery General Hospital of PLA Henan University of Chinese Medicine
    Shenzhen Center for Disease Control and Prevention Shanxi University
    The Fourth Hospital of Hebei Medical University 306 Hospital PLA
    The second Hospital of Hebei Medical University Xinxiang Medical University
    Weifang Medical University Liaoning Medical University

    Publications

    [1]

    Xiaobo Li, Chengcheng Zhang, Qian Bian, et al. Integrative Functional Transcriptomic Analyses Implicate Specific Molecular Pathways in pulmonary toxicity from Exposure to Aluminum Oxide Nanoparticles[J]. Nanotoxicology, 2016, 10(7):957-969. Doi: 10.3109/17435390.2016.1149632.

    [2]

    Li et al. An acetyl-L-carnitine switch on mitochondrial dysfunction and rescue in the metabolomics study on aluminum oxide nanoparticles[J]. Particle and Fibre Toxicology, 2016, 13:4, DOI 10.1186/s12989-016-0115-y.

    [3]

    Li et al. Suppression of PTPN6 exacerbates aluminum oxide nanoparticle-induced COPD-like lesions in mice through activation of STAT pathway[J]. Particle and Fibre Toxicology, 2017, 14:53, DOI 10.1186/s12989-017-0234-0.

    [4]

    Jian Cui, You Fu, Runze Lu, et al. Metabolomics analysis explores the rescue to neurobehavioral disorder induced by maternal PM2.5 exposure in mice[J]. Ecotoxicology and Environmental Safety 169 (2019) 687–695.

    [5]

    Xiaobo Li, Jian Cui, Hongbao Yang, et al. Colonic Injuries Induced by Inhalational Exposure to Particulate-Matter Air Pollution[J]. Adv. Sci. 2019, 1900180. DOI: 10.1002/advs.201900180.

    [6]

    Xiaobo Li, Hao Sun, Bin Li, et al. Probiotics Ameliorate Colon Epithelial Injury Induced by Ambient Ultrafine Particles Exposure[J]. Adv. Sci. 2019, 1900972. DOI: 10.1002/advs.201900972.

    [7]

    Yingfeng Du, Ludan Hou, Chen Chu, et al. Characterization of serum metabolites as biomarkers of carbon black nanoparticles-induced subchronic toxicity in rats by hybrid triple quadrupole time-of-flight mass spectrometry with non-targeted metabolomics strategy[J]. Toxicology, 2019, 426:152268.

    [8]

    Bin Han, Chen Chu, Xuan Su, et al. N6-methyladenosinedependent primary microRNA-126 processing activated PI3K-AKT-mTOR pathway drove the development of pulmonary fibrosis induced by nanoscale carbon black particles in rats[J]. Nanotoxicology, 2019, DOI: 10.1080/17435390.2019.1661041.

    [9]

    Chen Chu, Haiya Zhang, Shijie Cui, et al. Ambient PM2.5 caused depressive-like responses through Nrf2/NLRP3 signaling pathway modulating inflammation[J]. Journal of Hazardous Materials, 2019, 369: 180–190. https://doi.org/10.1016/j.jhazmat.2019.02.026.

    [10]

    Chen Chu, Lixiao Zhou, Heran Xie, et al. Pulmonary toxicities from a 90-day chronic inhalation study with carbon black nanoparticles in rats related to the systemical immune effects[J]. International Journal of Nanomedicine, 2019, 14: 2995–3013.

    [11]

    Jie Ning, Peiyuan Li, Boyuan Zhang, et al. miRNAs deregulation in serum of mice is associated with lung cancer related pathway deregulation induced by PM2.5[J]. Environmental Pollution, 2019, 254, 112875.

    [12]

    Wang Liyun, Liu Xingyu, Chen Lisha, et al. Harmful chemicals of heat not burn product and its induced oxidative stress of macrophages at air-liquid interface: Comparison with ultra-light cigarette[J]. Toxicology Letters, 2020, 331, 200–207.

    [13]

    Xuan Su, Junzhi Tian, Binghua Li, et al. Ambient PM2.5 caused cardiac dysfunction through FoxO1-targeted cardiac hypertrophy and macrophage-activated fibrosis in mice[J]. Chemosphere, 2020, 247, 125881. https://doi.org/10.1016/j.chemosphere.2020.125881.

    Frequently Asked Questions (FAQ)

    What aerosol types are supported by this inhalation exposure system?
    The system supports gas, liquid aerosol, and dust aerosol generation and exposure, maintaining stability deviations within ±8% for gas, ±10% for liquid aerosol, and ±20% for dust aerosol in strict accordance with OECD guidelines.
    What is the aerosol particle size distribution of the chamber?
    The aerosol particle size distribution features a Mass Median Aerodynamic Diameter (MMAD) of 1–3 μm and a Geometric Standard Deviation (GSD) of 1.5–3, ensuring optimal alveolar deposition for rodent models.
    How many animals can be tested simultaneously in the whole body exposure chamber?
    The system utilizes an individual cage design (one cage per rat) and can accommodate 20 to 80 rats for simultaneous inhalation testing under uniform exposure conditions.
    Which international regulatory standards and guidelines does this equipment comply with?
    It fully complies with OECD Guidelines (TG 403, 436, 412, 413), Chinese Pesticide Registration Standards (GB/T 15670 series), and New Chemical Substance Registration Guidelines by the Ministry of Ecology and Environment.
    What environmental parameters can be monitored and controlled during exposure?
    The system provides real-time monitoring and precise control over temperature, relative humidity, pressure difference, O2/CO2 concentrations, air inlet/exhaust flow, dilution flow, sampling flow, and total/remaining exposure time.
    Can this system support repeated-dose sub-chronic (90-day) inhalation studies?
    Yes, the system is engineered to reliably support both acute and long-term repeated-dose studies, including 28-day sub-acute (OECD 412) and 90-day sub-chronic (OECD 413) exposure protocols.

    Make An AppointmentLEAVE YOUR MESSAGE