The Dynamic Whole-body Exposure System for Rodents is an advanced solution designed for conducting inhalation exposure tests on rodents, including rats, mice, and guinea pigs. This state-of-the-art system facilitates exposure to various substances, such as gas, vapor, liquid aerosols, solid aerosols, and nanoparticle aerosols. As a leading factory and supplier in China, we ensure that our equipment meets the highest standards for safety and efficiency, making it an essential tool for researchers and laboratories engaged in respiratory toxicology studies. Optimize your research capabilities with our reliable and innovative exposure system.

    Application

    Drug Safety Evaluation

    Chemicals and Pesticide Safety Evaluation

    Inhalation Immunity and Environment Assessment

    Respiratory Disease Modeling and Drug Efficacy Evaluation

    Hazard Assessment and Radioactive Substances Protection

    Aerospace Medicine

    Features

    Uniformity & Stability: The uniformity and stability deviation of animal respiratory tract for gas is within ±8%, for liquid aerosol is within ±10%, while for dust aerosol is within ±20%, which conforms to technical requirements of OECD guidelines.

    Aerosol Particle Size Distribution: Particle size distribution is MMAD1-3μm, GSD1.5-3.

    Chamber Environment Controls: The temp, humidity, oxygen and carbon dioxide concentration of whole body exposure chamber during test meet requirements of inhalation guidelines.

    High Capacity Testing: One cage for one rat inhalation exposure can perform 20-80 rats test simultaneously.

    Real-Time Monitoring: Real-time monitor temp, humidity, pressure difference, oxygen and carbon dioxide concentration of exposure chamber during tests. Parameters can be controlled according to requirements of laboratory, e.g., air inlet flow, dilution flow, sampling flow, exhaust flow, exposure time, remaining time, etc.

    Standards

    OECD Guidelines

    ① OECD TG 403 Acute Inhalation Toxicity (2009).

    ② OECD TG 436 Acute Inhalation Toxicity. Acute Toxic Class Method (2009).

    ③ OECD TG 412 28d Sub-acute inhalation (2018).

    ④ OECD TG 413 90d Sub-chronic inhalation (2018).

    Pesticide Registration Standards

    ① GB /T 15670.6 ~2017 Toxicological test methods for pesticides registration—Part 6: Acute inhalation toxicity test.

    ② GB /T 15670.12 ~ 2017 Toxicological test methods for pesticides registration—Part 12: Short-term repeated dose 28-day inhalation toxicity study.

    ③ GB /T 15670.13 ~2017 Toxicological test methods for pesticides registration—Part 13: Subchronic toxicity study.

    ④ GB /T 15670.26 ~ 2017 Toxicological test methods for pesticides registration—Part 26: Chronic toxicity study.

    Registration of New Chemical Substances by Ministry of Ecology and Environment

    ① 403 Acute Inhalation Toxicity (2013, 2nd edition).

    ② 436 Acute Inhalation Toxicity Test: Acute Toxic Class Method (2013, 2nd edition).

    ③ 412 Sub-acute inhalation:28-days test (2013, 2nd edition).

    ④ 413 Sub-chronic inhalation:90-days test (2013, 2nd edition).

    Typical Users

    Institute of Environmental and Occupational Medicine, Academy of Military Medical Sciences Capital Medical University
    China Institute for Radiation Protection Guangxi University of Science and Technology
    Chinese Center for Disease Control and Prevention North China University of Science and Technology
    Institute of Laboratory Animals Science, CAMS & PUMC Shaanxi University of Chinese Medicine
    Jiangsu Provincial Center for Disease Control and Prevention Hebei Medical University
    Medical Research Center, Second Artillery General Hospital of PLA Henan University of Chinese Medicine
    Shenzhen Center for Disease Control and Prevention Shanxi University
    The Fourth Hospital of Hebei Medical University 306 Hospital PLA
    The second Hospital of Hebei Medical University Xinxiang Medical University
    Weifang Medical University Liaoning Medical University

    Publications

    [1] Xiaobo Li, Chengcheng Zhang, Qian Bian, et al. Integrative Functional Transcriptomic Analyses Implicate Specific Molecular Pathways in pulmonary toxicity from Exposure to Aluminum Oxide Nanoparticles[J]. Nanotoxicology, 2016, 10(7):957-969. Doi: 10.3109/17435390.2016.1149632.

    [2] Li et al.An acetyl-L-carnitine switch on mitochondrial dysfunction and rescue in the metabolomics study on aluminum oxide nanoparticles[J]. Particle and Fibre Toxicology, 2016,13:4, DOI 10.1186/s12989-016-0115-y.

    [3] Li et al. Suppression of PTPN6 exacerbates aluminum oxide nanoparticle-induced COPD-like lesions in mice through activation of STAT pathway[J]. Particle and Fibre Toxicology ,2017,14:53, DOI 10.1186/s12989-017-0234-0.

    [4] Jian Cui, You Fu, Runze Lu, et al. Metabolomics analysis explores the rescue to neurobehavioral disorder induced by maternal PM2.5 exposure in mice[J]. Ecotoxicology and Environmental Safety 169 (2019) 687–695.

    [5] Xiaobo Li, Jian Cui, Hongbao Yang,et al. Colonic Injuries Induced by Inhalational Exposure to Particulate-Matter Air Pollution[J]. Adv. Sci. 2019, 1900180. DOI: 10.1002/advs.201900180.

    [6] Xiaobo Li, Hao Sun, Bin Li, et al. Probiotics Ameliorate Colon Epithelial Injury Induced by Ambient Ultrafine Particles Exposure[J]. Adv. Sci. 2019, 1900972. DOI: 10.1002/advs.201900972.

    [7] Yingfeng Du, Ludan Hou, Chen Chu, et al. Characterization of serum metabolites as biomarkers of carbon black nanoparticles-induced subchronic toxicity in rats by hybrid triple quadrupole time-of-flight mass spectrometry with non-targeted metabolomics strategy{J}. Toxicology , 2019,426:152268.

    [8] Bin Han, Chen Chu, Xuan Su, et al. N6-methyladenosinedependent primary microRNA-126 processing activated PI3K-AKT-mTOR pathway drove the development of pulmonary fibrosis induced by nanoscale carbon black particles in rats[J]. Nanotoxicology, 2019, DOI: 10.1080/17435390.2019.1661041.

    [9] Chen Chu, Haiya Zhang, Shijie Cui, et al. Ambient PM2.5 caused depressive-like responses through Nrf2/NLRP3 signaling pathway modulating inflammation[J]. Journal of Hazardous Materials, 2019, 369: 180–190. https://doi.org/10.1016/j.jhazmat.2019.02.026.

    [10] Chen Chu, Lixiao Zhou, Heran Xie, et al. Pulmonary toxicities from a 90-day chronic inhalation study with carbon black nanoparticles in rats related to the systemical immune effects[J]. International Journal of Nanomedicine, 2019,14: 2995–3013.

    [11] Jie Ning, Peiyuan Li, Boyuan Zhang, et al. miRNAs deregulation in serum of mice is associated with lung cancer related pathway deregulation induced by PM2.5[J]. Environmental Pollution, 2019, 254,112875.

    [12] Wang Liyun, Liu Xingyu, Chen Lisha, et al. Harmful chemicals of heat not burn product and its induced oxidative stress of macrophages at air-liquid interface: Comparison with ultra-light cigarette[J]. Toxicology Letters, 2020, 331,200–207.

    [13] Xuan Su, Junzhi Tian, Binghua Li, et al. Ambient PM2.5 caused cardiac dysfunction through FoxO1-targeted cardiac hypertrophy and macrophage-activated fibrosis in mice[J]. Chemosphere, 2020,247,125881. https://doi.org/10.1016/j.chemosphere.2020.125881.

    Frequently Asked Questions (FAQ)

    1. What are the key applications of this inhalation exposure system?

    The system is widely used for Drug Safety Evaluation, Chemicals and Pesticide Safety Evaluation, Inhalation Immunity and Environment Assessment, Respiratory Disease Modeling and Drug Efficacy Evaluation, Hazard Assessment and Radioactive Substances Protection, and Aerospace Medicine.

    2. What standards and guidelines does the system conform to?

    It complies with multiple international and national standards, including OECD Guidelines (TG 403, TG 436, TG 412, and TG 413), Pesticide Registration Standards (GB/T 15670.6, .12, .13, and .26), and the Registration of New Chemical Substances regulations by the Ministry of Ecology and Environment.

    3. What is the aerosol particle size distribution of the system?

    The system ensures precise aerosol particle size distribution, achieving a Mass Median Aerodynamic Diameter (MMAD) of 1-3μm and a Geometric Standard Deviation (GSD) of 1.5-3.

    4. How many animals can be tested simultaneously?

    With a highly efficient design of one cage for one rat inhalation exposure, the system can perform tests on 20 to 80 rats simultaneously.

    5. What environmental parameters are monitored and controlled in real-time?

    The system monitors temperature, humidity, pressure difference, oxygen, and carbon dioxide concentrations in real-time. Laboratory managers can also control parameters such as air inlet flow, dilution flow, sampling flow, exhaust flow, and exposure time.

    6. What is the uniformity and stability deviation of the exposure chamber?

    The uniformity and stability deviation of the animal respiratory tract is within ±8% for gas, within ±10% for liquid aerosol, and within ±20% for dust aerosol, fully conforming to OECD guidelines.

    Make An AppointmentLEAVE YOUR MESSAGE