Request a Quote
Leave Your Message

Eight-stage Andersen Cascade Impact Sampler (ACI)

Model HRH-ACI283 Eight-stage Andersen cascade impactor (ACI) is a multi-stage, critical orifice impact sampler for aerodynamic particle size distribution determination for inhaled fine particles, consisting of multi-stage cascade impactors and membrane in the last stage. When testing MDIs and nasal sprays, the top cover is connected to the induction port and the inhaler by an adapter. When testing DPIs, a pre-separator should be mounted to the top layer to collect large quantities of non-inhalable powder particles. It conforms to USP and Ph. Eur. as well as aerodynamic particle size distribution determination of inhaled fine particles of ChP 2020.

    Application

    APSD tests for MDIs/DPIs/Sprays.

    Features

    1.Pre-separator ensures accurate separation of coarse particles.

    2.Sampling flow rate:28.3L/min (optional 60L/min, 90L/min).

    3.Low cost and easy operation.

    4.Effectively prevent particle bounce and re-entrainment.

    5.USP, Ph. Eur. and ChP compliant.

    6.Model HRH-ACI283 Eight-stage Andersen cascade impactor comprises eight stainless steel impaction plates manufactured with extremely high precision, each containing up to 400 precision-machined orifices. The internal diameter tolerances of these stage orifices are held to stringent micron-level specifications, as the linear velocity of the airflow through the orifices directly governs the aerodynamic cutoff diameter (D50) for each stage. When employed for high-resistance DPI testing, a pre-separator must be connected in series to pre-collect coarse carrier particles (e.g., lactose) and large particle mass (LPM) upstream, thereby fundamentally preventing severe particle bounce, fragmentation, and re-entrainment on the fine stages—phenomena that would otherwise compromise the integrity of the APSD profile.

    Specification

    1.Main components: 9 stainless steel impactors, 9 stainless steel collection cups, 1 induction port, 1 pre-separator.

    2.Anti-corrosion and Anti-static Material: Entirely from SUS316 stainless steel, capable of withstanding prolonged immersion and repeated cleaning cycles with a wide range of highly aggressive solvents.

    3.Applicable Flow Rates: The baseline standard flow rate is 28.3 L/min. For DPIs with varying resistance coefficients, extended test configurations at 60 L/min and 90 L/min are also available.

    4.Sampling particle size: 0.4 -9 micron.

    5.Dimensions: impactor φ97mm×221mm, pre-separator φ76mm×148mm.

    6.Weight: 8.1kg (impactor 5.1kg, pre-separator 1.6kg, induction port 1.4kg).

    Compliance

    USP, Ph.Eur. and ChP 2020

    光影魔术手拼图2

    Typical Users

    Zhejiang Heze Pharmaceutical Technology Co., Ltd.

    Suzhou Xishan Zhongke Drug R&D Co. Ltd.

    Suzhou Jingzida Testing Service Co., Ltd.

    Zhejiang Xianju Pharmaceutical Technology Co., Ltd.

    Nanjing Licheng Pharmaceutical Co., Ltd.

    Shenyang Pharmaceutical University Wuya College of Innovation

    Hefei Licheng Pharmaceutical Co., Ltd.

    Hainan Meikangda Pharmaceutical Co., Ltd.

    Beijing DYNE High-tech Pediatric Pharmaceutical R&D Institute Co., Ltd.

    Shandong Dyne Marine Organism Pharmaceutical Co., Ltd.

    Make An AppointmentLEAVE YOUR MESSAGE