Fine Particle Dose Measuring for Nasal Sprays - China Suppliers & Factory Solutions
Features
Cascade impactors are used to capture 0-10μm particles. The combination of cascade impactor with nasal spray expansion chamber is used to measure fine particle dose of drugs in nasal sprays and nasal aerosols.
Application
Nasal Spray FPD Tests
Optimized for assessing fine particle dose deposition profiles in nasal drug delivery systems.
Specification
1L Capacity
Used in nasal aerosols to maximize deposition below the top stage.
2L Capacity
Used in nasal sprays to maximize nebulization and deposition.
5L Capacity
For some stronger nasal sprays, additional room is required to be able to generate aerosol plume.
Accessories
Inhaler Testing Data Analysis Software Instruction
The main interface of the analysis software is shown in Figure 20. After inputting flow, the software will automatically calculate the cutting particle size. The information related to the experiment can be filled in on the right. The current experiment information can be saved by the Save button. Open the previously saved experiment information by the Open button and click the Next button to enter the data input interface after confirming the flow rate.
In the data input interface, each column represents an experiment, and each row corresponds to a different stage of the device. The number of experiments can be selected on the right side of the data sheet, and open data files and save data as files by Open and Save Button. After data input is completed, click the Next button to enter the result display interface. The result display interface can display parameters (such as MMAD and GSD) of each experiment as well as particle size distribution fitting curve and scatter diagram. It's allowed to choose to display the curve of any experiment or the curve of all experiments. Click the right mouse button in terms of graphs to export the curve graph.
Compliance
FDA (2003)
Bioavailability and Bioequivalence Studies for Nasal Aerosols and Nasal Sprays for Local Action
FDA (2002)
Nasal Spray, Inhalation Solution, Suspension & Spray Drug Products
Ph.Eur. 2021 10.5
Nasal Preparations (Dosage Forms 0676)
Typical Users
- United Arab Emirates University
- Genix Pharma Private Limited
- Drug International Limited
- Endocrine Technologies Llc
- Novel Phase
- Divine Healthcare Pvt. Ltd.
- Cipla Ltd.
- JOINN Laboratories
- Pharmaron Beijing Co., Ltd.
- Boji Medical Technology Co., Ltd.
- Tianjin Pharmaceutical Research Institute Co., Ltd.
- China State Institute of Pharmaceutical Industry (Haimen) R&D Co., Ltd.
- Shenyang SYRICI Testing Co., Ltd (SYRICIT)
- Guangdong Zhongke Yinghai Tech Co., Ltd.
- Jiangsu Medicine Research Institute
- Chinese Academy of Sciences Shanghai Institute of Materia Medica
- Shenyang Pharmaceutical University Wuya College of Innovation
- Jiangxi University of Chinese Medicine
- Kunming Institute of Zoology. Cas
- Zhongshan Research Institute, Shanghai Institute of Materia Medica
- ZhongShan Institute for Drug Discovery
- Shanghai Xiandai Medicine Preparation Engineering Research Centre Co.,Ltd.
- Northeastern University
- China Institute for Radiation Protection
- Hubei Provincial Center for Disease Control and Prevention
- Inner Mongolia Medical University
- Weifang Medical University
- Suzhou Jingzida Testing Service Co., Ltd.
- Suzhou Inhal Pharma Co., Ltd.
- Zhejiang Cdmo Pharmaceutical Co., Ltd
- Hangzhou Zhezhong Pharmaceutical Technology Co., Ltd.
- Jinan Kangqiao Medical Technology Co., Ltd.
- Anhui JieXi Pharmaceutical Co., Ltd.
- Beijing Xingyuanxiang Biotechnology (Group) Co., Ltd.
- Hunan Prima Pharmaceutical Research Center Co., Ltd.
- Beijing Wehand-bio Pharmaceutical Co.,ltd
- Jinan Baohede Pharmaceutical Technology Co., Ltd.
- Shandong Innovative Drug Research and Development Co., Ltd.
- Zhongshan Liansi Chemical Technology Co., Ltd.
- Jiangxi Zhonglu Science & Technology Co., Ltd.
- Shanghai Zezheng Biopharmaceutical Co., Ltd.
- Guangzhou Puzhiyun Information Technology Co., Ltd.
- Guangzhou Coslan Scientific Instrument Co., Ltd.
- Hainan Dayi Scientific Instrument Co., Ltd.
Frequently Asked Questions
What is the purpose of using cascade impactors with nasal spray expansion chambers?
Cascade impactors are utilized to capture particles within the 0-10μm range. When combined with a nasal spray expansion chamber, they measure the fine particle dose (FPD) of drugs delivered via nasal sprays and nasal aerosols.
How do I choose the right expansion chamber capacity for nasal testing?
Choose 1L capacity for nasal aerosols to maximize deposition below the top stage. Use 2L capacity for general nasal sprays to maximize nebulization. Select 5L capacity for stronger nasal sprays that require extra room for aerosol plume generation.
Is an expansion chamber required for Nasal Powder FPD testing?
No, it is not mandatory. The test method for Nasal Powder FPD is the same as for Dry Powder Inhalers (DPIs), utilizing the same test instruments and accessories without needing a pre-separator.
What parameters does the Inhaler Testing Data Analysis Software calculate?
The analysis software automatically calculates the cutting particle size based on the flow rate. It displays key experimental parameters such as MMAD (Mass Median Aerodynamic Diameter), GSD (Geometric Standard Deviation), particle size distribution fitting curves, and scatter diagrams.
Which regulatory standards do the nasal spray testing setups comply with?
The testing systems comply with FDA Bioavailability and Bioequivalence Studies (2003), FDA Nasal Spray, Inhalation Solution, Suspension & Spray Drug Products guidelines (2002), and Ph.Eur. 2021 10.5 Nasal Preparations (Dosage Forms 0676).