Request a Quote
Leave Your Message

High-speed Flavor and Fragrance Precision Injector

Model HRH-286K flavor and fragrance precision injector is mainly used in tobacco research organizations to inject flavors and fragrances into cigarettes to change taste of cigarettes or filters as well as perform biosafety evaluation tests of adding flavor and fragrance to cigarettes. Through computer control, it can complete actions automatically including sorting, loading, rotation, unloading, flavor and fragrance filling, injecting, etc. Injection length and dosage are accurately controlled. Moreover, there are single injection and double injection modes to adapt to different production speeds.

    Features

    Sample diameter: φ4.5-φ8.2, also fit for regular diameter, fine and ultra-fine cigarettes.

    Sample length: 40-100mm for IQOS cigarettes and ultra-long cigarettes.

    Injection speed: dual-channel simultaneous injection, as fast as 10 cigarettes per minute.

    Injection volume: min. 0.1ul.

    Injection depth: 1mm-80mm.

    Injection error range: within 1% of injected dose.

    Bin capacity: 500 pcs (dia. 8mm) or 900 pcs (dia. 5.2mm).

    Injection mode: cigarette stick injection mode, fixed length uniform injection mode, single-point injection mode, spiral injection mode.

    Automated flavor and fragrance filling: 6 bottles of flavor can be placed at one time, 4000ul per bottle.

    Working mode: single-channel mode, dual-channel mode.

    Application

    Applicable to cigarette flavor research of tobacco technical centers and other tobacco research institutions.

    Specification

    Cigarette length 40~100mm adjustable
    Cigarette diameter Φ4.5—Φ5.5, Φ6.5—Φ7.5, Φ7.5—Φ8.2
    Sorting speed 12 pcs/min
    Position accuracy 0.1mm
    Load cigarettes one at a time >600pcs
    Syringe capacity 25μl, 50μl, 100μl, 250μl optional
    Injection dose 0.1ul~25ul
    Injection length 1mm~80mm adjustable
    Injection length accuracy 0.1mm
    Injection precision ±1%
    Injection rate: Injection speed can be adjusted
    Max. production speed 12pcs/min
    Spice bottle capacity 4ml
    Temperature measuring range -20~80℃
    Temperature measuring accuracy 0.3℃
    Humidity measuring range 0~100%
    Humidity measuring accuracy ±0.5%RH
    Real-time prompts for running status, operation status, and errors.
    Power supply 220V 50Hz 10A
    Weight about 40kg(host)
    Dimensions 950mm×500 mm ×950mm(host)

    Standards

    YCT 145.8-1998 Tobacco Flavor-General Method for Evaluation of Flavor Quality