Fully Automated Food Microbiology Station HRH-B20 - China Suppliers & Factory for Efficient Microbiology Testing
Features
Fully automated design: with built-in standard sample preparation programs for multi-species bacteria testing, the instrument could complete the whole process automatically after the user places samples and consumables well (Petri dishes, tubes, etc.).
Code scanning module: automatically identifies the QR code/barcode on the sterile bag, enters sample information into the system, and determines the specific programs.
Petri dish storage module: up to 396 empty and agar-filled Petri dishes can be stored to meet the spreading and pouring method requirements.
Liquid flapping and homogenizing module: dilute the samples with 10 times liquid, then homogenize the sample by auto-flapping. The integrated heat-sealing function retains the original homogenizing liquid.
Gradient dilution module: perform 10, 100, 1000 times gradient dilution for 20 samples. Cross-contamination is avoided by adopting 5ml disposable pipette tips.
Agar thermostatic function: magnetic stirring and thermal insulation functions ensure agar does not solidify or deposit. The pipeline is easy to dismantle and sterilize.
Pipetting module: with high precision, cross-contamination is avoided by adopting 5ml disposable pipette tips.
Bacterial spreading module: rotary and uniform spreading for each sample by an individually soft spreading stick to avoid cross-contamination and increase efficiency. After spreading, the agar can be overlaid by the top medium.
Agar filling module: up to 3 kinds of agar can be filled and shaken, and multi-species bacteria can be performed in one test. Working under metal bath insulation, the filling tube is reusable and easy to dismantle to sterilize.
Robotic arm: 2 sets of high-precision robotic arms with intelligent control, the program centralizes the scheduling of all modules to improve test efficiency.
Inkjet printing module: inkjet prints the information on Petri dishes, which makes it easy to distinguish the sample, gradient, parallel sample and other information.
UV sterilization: UV sterilize the system to prevent airborne bacteria contamination.
Aseptic environment: a laminar flow hood is set on top of the equipment, and the internal micro-positive pressure of the system ensures aseptic.
Multi-terminal remote monitoring: the software’s main interface and real-time images of the internal operation can be remotely monitored through mobile phones and computer clients.
Multi-functionality: can be used individually for sample flapping, pipetting, gradient dilution, Petri dish filling and other routine laboratory operations.
Application
It can automatically complete the determination of total colony count, coliform count, bifidobacteria test, Staphylococcus aureus test, Bacillus cereus test, Clostridium perfringens test, bifidobacteria test, lactobacillus test, Enterobacteriaceae test, Listeria monocytogenes test, molds and yeast counts, etc.
Specification
| Item | Technical Specification |
| Model | HRH-B20 |
| Sample throughput | 20 |
| Bacteria Testing Throughput | 3 pouring + 1 spreading assay (e.g., colony count, coliforms, mold yeast, aureus) |
| Petri Dish Capacity | 396 |
| Sample Processing Speed | 140 min (4 bacteria), 70 min (total colony & coliform) |
| Liquid Filling | <1% RSD (n=25@250mL transfer volume by weight). Accuracy ±2% |
| Flapping Homogenizing Speed | 3~12 squeezes/sec |
| Robotic Arm | Dual robotic arms, accuracy 0.1mm |
| Gradient Dilution | 10/100/1000 times gradient dilution, 5ml pipetting, Precision ≤1%RSD (n=10@ 5mL). Accuracy ± 2% |
| Agar pouring | 3 agar filling ports, which can work independently with the shaking module. Agar volume and shaking speed can be set |
| Pipetting | Volume ≤ 5ml. Precision < 1% RSD (n=10 @ 5mL). Accuracy ± 1% |
| Air supply | 30L, 5Bar |
| Power Supply | 220VAC 50Hz |
| Weight | Approx. 400kgs |
| Dimensions | 1540mm×760mm×2200mm |
Configuration
| Host | 1 set |
| Industrial Control PC | 1 set |
| Air Pump | 1 set |
| Dedicated Control Software | 1 set |
| Φ6 PU Tube | 3m |
| Dilution tube | 100 ea |
| 5ml Pipette tips | 200 ea |
| 90mm Petri dish | 500 ea |
| Sterile sample bag | 20 ea |
| Certificate, Warranty Card, User Manual | 1 set |
Frequently Asked Questions (FAQ)
Q: What is the sample throughput and Petri dish capacity of the HRH-B20?
The HRH-B20 features a sample throughput of 20 samples and has a Petri dish storage module that can hold up to 396 empty and agar-filled Petri dishes to support both spreading and pouring methods.
Q: How does the system prevent cross-contamination during testing?
Cross-contamination is strictly avoided by adopting 5ml disposable pipette tips for gradient dilution and pipetting, using individual soft spreading sticks for each sample in the spreading module, and featuring a built-in UV sterilization system alongside a top-mounted laminar flow hood to maintain an aseptic micro-positive pressure environment.
Q: What types of bacteria tests can be automatically performed?
The station can automatically complete determinations for total colony count, coliform count, bifidobacteria test, Staphylococcus aureus test, Bacillus cereus test, Clostridium perfringens test, lactobacillus test, Enterobacteriaceae test, Listeria monocytogenes test, as well as molds and yeast counts.
Q: Can the system be monitored remotely?
Yes, the system supports multi-terminal remote monitoring. Users can remotely check the software's main interface and view real-time images of the internal operations through mobile phones and computer clients.
Q: What is the processing speed of the station?
The sample processing speed is approximately 140 minutes when testing for 4 types of bacteria, and 70 minutes for a combined total colony and coliform test.
Q: Can individual modules of the HRH-B20 be used separately?
Yes, the equipment offers multi-functionality and can be used individually for sample flapping, pipetting, gradient dilution, Petri dish filling, and other routine laboratory operations.