Introducing our fully automatic QuEChERS pesticide residue preparation system, designed to revolutionize the testing process for suppliers and factories in China. This state-of-the-art system addresses the inefficiencies and limitations of traditional QuEChERS methods, which are often labor-intensive and prone to errors, especially with large sample quantities. Our innovative solution combines automated liquid, salt, and ceramic homogenization with oscillating, vortexing, centrifuging, ice bath, and precision pipetting functionalities, With the capability to process up to 120 samples in a single run, this system ensures a seamless workflow that significantly enhances detection accuracy and stability while eliminating manual errors. By integrating these advanced features, our fully automated system streamlines the testing process, making it an essential tool for suppliers and factories aiming to improve efficiency and reliability in pesticide residue analysis. Experience the future of pesticide testing with our cutting-edge automation technology tailored for the Chinese market

    Features
    ⚙️

    Fully Automated Design

    The system established a standard preparation process for QuEChERS method. After placing samples and test tubes, the system can carry out actions automatically such as oscillating, vortexing, centrifugating, and pipetting.

    ⚖️

    Automated Salt and Ceramic Homogenizer Feeding

    The user-defined system can realize automatic and accurate feeding of mixed salt.

    🔄

    Oscillating Compatibility

    Four test tubes oscillate simultaneously with adjustable speed and time. The structure is compatible with 50ml/15ml test tubes.

    🌀

    Horizontal Centrifuge Module

    Integrate 4-rotor horizontal centrifuge and is compatible with 50ml/15ml test tubes simultaneously, with adjustable centrifugal time and speed.

    🌪️

    Dual-channel Vortex Module

    Each channel is driven independently and vortex time is adjustable.

    🤖

    High-precision Pipetting Robot Arm

    Integrate high-precision pipetting module with precise liquid-level detection.

    ♻️

    Automated Tip Replacement

    Replace tips for each pipetting to avoid cross-contamination.

    💉

    Intelligent Syringe Pump

    Equipped with 4-way or 8-way switching valve, which can fully meet liquid filling requirements in routine tests. Real-time tube-level monitoring guarantees pipetting accuracy and reliability.

    ❄️

    Ice Bath

    Meet requirements of ChP2020.

    ⚠️

    Multi-directional Fault Monitoring

    Can monitor real-time failures of centrifugal weight match, cap screw/unscrew, tube delivering, ceramic homogenizer feeding, and other failures during operation, and feedback to the user interface in time.

    📱

    Multi-terminal Remote Monitoring

    Monitor software main interface and real-time internal operation remotely via mobile phone and computer.

    🔌

    Integration Support

    Supports integration with automated filtration modules or nitrogen blow filtration modules.

    Components
    Application

    QuEChERS sample preparation on plant-origin food, herbs, tobacco and imported & exported agricultural products, tea and herbs, etc.

    HMI (Human Machine Interface)

    1. Main Interface: Easy operation, real-time display status of function modules and procedure of online testing.

    2. Program Setting Interface: test procedure is built-in and can be used directly, including pesticide residue QuEChERS preparation for vegetables and fruits, cereals and nuts. Program parameters can be adjusted and optimized per actual requirements, and also can be adjusted partially or by user design under guidance of manufacturer.

    3. Remote Monitor

    Specification
    Item Technical Parameters
    Model HRH-Q32 HRH-Q40 HRH-Q60 HRH-Q40PRO HRH-Q60PRO HRH-Q120
    Sample Throughput 32 /test 40 /test 60 /test 40 /test 60 /test 120 /test
    Test Efficiency Est. 5min/sample, total 2hrs. 40min Est. 5.5min/sample, total 3hrs. 40min Est. 5.5min/sample, total 5hrs. 25min Est. 5min/sample, total 3hrs. 20min Est. 4.7min/sample, total 4hrs. 40min Est. 2.7min/sample, total 5hrs. 20min
    Filling Acc. ≤0.5% RSD, 4-way switch valve ≤0.5% RSD, 8-way switch valve
    Pipetting Acc. Vol.≤5ml, Acc.≤1% RSD Vol.≤1ml, Acc.≤1% RSD Vol.≤5ml, Acc.≤1% RSD
    Salt Adding Acc. ≤5% RSD 1. Salt bin: ≤5% RSD
    2. Individual salt tube
    Shaking 4 stations, 0-500 RPM, speed and time adjustable 8 stations, 0-500 RPM, speed and time adjustable 8 stations, 0-1000 RPM, speed and time adjustable
    Vortex Speed 2 stations, ≥3500RPM 8 stations, ≥3500RPM
    Centrifuge Speed 0-5000 RPM, speed and time adjustable
    Ice Bath Acc. / ±1℃
    Centrifuge Throughput 4 stations, compatible with 50ml/15ml tubes 8 stations, compatible with 50ml/15ml tubes
    Power Supply 220VAC 50Hz or customized
    Dimensions 1270×910×2100mm 1480×910×2100mm 2440×1010×2150mm
    Configuration
    Type Description Quantity
    Standard Host 1 set
    Industrial Controlled PC 1 set
    Air Compressor 1 set
    Dedicated Control Software 1 set
    Φ6 PU Tube 3m
    50ml Test Tube 1 bag (100 tubes)
    15ml Test Tube 2 bags (100 tubes)
    1ml Tip (HRH-Q40, HRH-Q60) 2 boxes (392 tips)
    5ml Tip (HRH-Q32, HRH-Q40PRO, HRH-Q60PRO, HRH-Q120) 2 boxes (100 tips)
    Ceramic Homogenizer 100 pcs
    Certificate, Warranty Card, User Manual 1 set
    Optional Built-in filtration module (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) 1 set
    Nitrogen evaporation & filtration system (930×910×2100 mm) (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) 1 set
    Veterinary drug residue column-based SPE module (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) 1 set
    Integrated salting out module (for HRH-Q120 only) 1 set
    Finished sample refrigeration module (for HRH-40PRO, HRH-60PRO only) 1 set
    Internal standard addition module (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) 1 set
    Multi-protocol operation (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) 1 set
    Compliance
    • GB 23200.113—2026 National Food Safety Standard Determination of 242 Pesticides and Metabolites Residues in Foods of Plant Origin - Gas Chromatography-tandem Mass Spectrometry Method.
    • GB 23200.121—2026 National food safety standard—Determination of 352 pesticides and metabolites residues in foods of plant origin—Liquid chromatography-tandem mass spectrometry method.
    • Pharmacopoeia of the People's Republic of China 2025 Edition (Volume IV), 2341 – Method 4 for the Determination of Pesticide Multiresidues: Determination of Pesticide Multiresidues (Mass Spectrometry); Method 5: Determination of Prohibited Pesticide Multiresidues in Medicinal Materials and Decoction Pieces (Botanical).
    • AOAC 2007.01 Determination of pesticide residues in food using acetonitrile extraction and magnesium sulfate separation.
    • EN 15662:2018 Foods of plant origin - Multimethod for the determination of pesticide residues using GC- and LC-based analysis following acetonitrile extraction/partitioning and clean-up by dispersive SPE - Modular QuEChERS-method.
    Frequently Asked Questions (FAQ)
    What applications is this automated QuEChERS system suitable for?

    It is designed for automated QuEChERS sample preparation of plant-origin food, herbs, tobacco, tea, and imported/exported agricultural products.

    What tube sizes are compatible with the oscillating and centrifuge modules?

    The system is compatible with both 50ml and 15ml test tubes for oscillating, vortexing, and horizontal centrifugation operations.

    How does the system prevent cross-contamination during liquid handling?

    It features an automated tip replacement mechanism, replacing the pipetting tips for each operation to completely avoid cross-contamination.

    Can I monitor the extraction process remotely?

    Yes, the system supports multi-terminal remote monitoring, allowing you to monitor the main software interface and real-time internal operations via mobile phones and computers.

    Does the system comply with international food safety standards?

    Yes, it fully complies with major global standards including GB 23200.113—2026, GB 23200.121—2026, ChP 2025 (Volume IV), AOAC 2007.01, and EN 15662:2018.