Introducing the fully automated QuEChERS pesticide residue preparation system, an essential innovation for laboratories seeking efficiency and precision. While the traditional QuEChERS method is popular, it often proves to be labor-intensive and prone to errors, especially when dealing with large sample quantities. This state-of-the-art system, designed by leading China suppliers, streamlines the entire process by integrating essential functions such as automated liquid, salt, and ceramic homogenizer feeding, oscillating, vortexing, centrifuging, and ice bath techniques, all while utilizing precision pipetting, Capable of processing 32, 40, 60, or even 120 samples in a single run, this automated solution significantly enhances test efficiency and accuracy. By eliminating the need for manual input, it reduces human errors and ensures stable detection results. Manufactured in a reliable factory, this QuEChERS system revolutionizes pesticide residue testing, making it an ideal choice for laboratories aiming to achieve fully automated detection without compromising on quality

    Application

    QuEChERS sample preparation on plant-origin food, herbs, tobacco and imported & exported agricultural products, tea and herbs, etc.

    Components

    Fully Automated QuEChERS System (1)

    Features

    1

    Fully Automated Design

    The system established a standard preparation process for QuEChERS method. After placing samples and test tubes, the system can carry out actions automatically such as oscillating, vortexing, centrifugating, and pipetting.

    2

    Automated Salt and Ceramic Homogenizer Feeding

    The user-defined system can realize automatic and accurate feeding of mixed salt.

    3

    Oscillating Compatibility

    Four test tubes oscillate simultaneously with adjustable speed and time. The structure is compatible with 50ml/15ml test tubes.

    4

    Horizontal Centrifuge Module

    Integrate 4-rotor horizontal centrifuge and is compatible with 50ml/15ml test tubes simultaneously, with adjustable centrifugal time and speed.

    5

    Dual-channel Vortex Module

    Each channel is driven independently and vortex time is adjustable.

    6

    High-precision Pipetting Robot Arm

    Integrate high-precision pipetting module with precise liquid-level detection.

    7

    Automated Tip Replacement

    Replace tips for each pipetting to avoid cross-contamination.

    8

    Intelligent Syringe Pump

    Equipped with 4-way or 8-way switching valve, which can fully meet liquid filling requirements in routine tests. Real-time tube-level monitoring guarantees pipetting accuracy and reliability.

    9

    Ice Bath

    Meet requirements of the Pharmacopoeia.

    10

    Multi-directional Fault Monitoring

    Can monitor real-time failures of centrifugal weight match, cap screw/unscrew, tube delivering, ceramic homogenizer feeding, and other failures during operation, and feedback to the user interface in time.

    11

    Multi-terminal Remote Monitoring

    Monitor software main interface and real-time internal operation remotely via mobile phone and computer.

    12

    System Integration Options

    Supports integration with automated filtration modules or nitrogen blow filtration modules.

    HMI

    1. Main Interface Easy operation, real-time display status of function modules and procedure of online testing.
    Fully Automated QuEChERS System (2)
    2. Program Setting Interface Test procedure is built-in and can be used directly, including pesticide residue QuEChERS preparation for vegetables and fruits, cereals and nuts. Program parameters can be adjusted and optimized per actual requirements, and also can be adjusted partially or by user design under guidance of manufacturer.
    Fully Automated QuEChERS System (3)
    3. Remote Monitor Supports remote monitoring of software main interface and real-time internal operations.
    Fully Automated QuEChERS System (4)

    Specification

    Item Technical Parameters
    Model HRH-Q32 HRH-Q40 HRH-Q60 HRH-Q40PRO HRH-Q60PRO HRH-Q120
    Sample Throughput 32 /batch 40 /batch 60 /batch 40 /batch 60 /test 120 /batch
    Test Efficiency Est. 5min/sample, total 2hrs. 40min Est. 5.5min/sample, total 3hrs. 40min Est. 5.5min/sample, total 5hrs. 25min Est. 5min/sample, total 3hrs. 20min Est. 4.7min/sample, total 4hrs. 40min Est. 2.7min/sample, total 5hrs. 20min
    Filling Acc. ≤0.5% RSD, 4-way switch valve ≤0.5% RSD, 8-way switch valve
    Pipetting Acc. Vol.≤5ml, Acc.≤1% RSD Vol.≤1ml, Acc.≤1% RSD Vol.≤5ml, Acc.≤1% RSD
    Salt Adding Acc. ≤5%RSD
    1. Salt bin: ≤5%RSD
    2. Individual salt tube
    Shaking 4 stations, 0-500 RPM, speed and time adjustable 8 stations, 0-500 RPM, speed and time adjustable 8 stations, 0-1000RPM, speed and time adjustable
    Vortex Speed 2 stations, ≥3500RPM 8 stations, ≥3500RPM
    Centrifuge Speed 0-5000 RPM, speed and time adjustable
    Ice Bath Acc. / ±1℃
    Centrifuge Throughput 4 stations, compatible with 50ml/15ml tubes 8 stations, compatible with 50ml/15ml tubes
    Power Supply 220VAC 50Hz or customized
    Dimensions 1270×910×2100mm 1480×910×2100mm 2440×1010×2150mm

    Configuration

    Standard Host 1 set
    Industrial Controlled PC 1 set
    Air Compressor 1 set
    Dedicated Control Software 1 set
    Φ6 PU Tube 3m
    50mL Test Tube 1 bag
    15mL Test Tube 2 bags
    1mL Pipette Tip (HRH-Q40, HRH-Q60) 2 boxes
    5mL Pipette Tip (HRH-Q32, HRH-Q40PRO, HRH-Q60PRO, HRH-Q120) 2 boxes
    Ceramic Homogenizer 100 pcs
    Certificate, Warranty Card, User Manual 1 set
    Optional Built-in Filtration Module (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) 1 set
    Nitrogen Blow-Down Filtration Module (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) 1 set
    SPE Module for Veterinary Drug Residues (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) 1 set
    Integrated Salt Addition Module (for HRH-Q120 only) 1 set
    Chilled Extract Storage Module (for HRH-40PRO, HRH-60PRO only) 1 set
    Internal Standard (ISTD) Addition Module 1 set
    Multi-protocol Processing (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) 1 set

    Compliance

    1. GB 23200.113—2026 National Food Safety Standard Determination of 242 Pesticides and Metabolites Residues in Foods of Plant Origin - Gas Chromatography-tandem Mass Spectrometry Method.
    2. GB 23200.121—2026 National food safety standard—Determination of 352 pesticides and metabolites residues in foods of plant origin—Liquid chromatography-tandem mass spectrometry method.
    3. Pharmacopoeia of the People's Republic of China 2025 Edition (Volume IV), 2341 – Method 4 for the Determination of Pesticide Multiresidues: Determination of Pesticide Multiresidues (Mass Spectrometry); Method 5: Determination of Prohibited Pesticide Multiresidues in Medicinal Materials and Decoction Pieces (Botanical).
    4. AOAC 2007.01 Determination of pesticide residues in food using acetonitrile extraction and magnesium sulfate separation.
    5. EN 15662:2018 Foods of plant origin - Multimethod for the determination of pesticide residues using GC- and LC-based analysis following acetonitrile extraction/partitioning and clean-up by dispersive SPE - Modular QuEChERS-method.

    Frequently Asked Questions (FAQ)

    What samples are suitable for the Fully Automated QuEChERS System?
    The system is ideal for QuEChERS sample preparation on plant-origin food, herbs, tobacco, tea, and imported & exported agricultural products.
    How does the system prevent cross-contamination?
    The system features an Automated Tip Replacement module, replacing pipette tips for each liquid handling and pipetting step to effectively avoid cross-contamination.
    Can I monitor the preparation process remotely?
    Yes, the system supports multi-terminal remote monitoring. Users can track the software main interface and view real-time internal operations via mobile phone or computer.
    Which standards and regulations does this system comply with?
    It complies with major international standards including GB 23200.113-2026, GB 23200.121-2026, the 2025 Edition of the Chinese Pharmacopoeia (Volume IV), AOAC 2007.01, and EN 15662:2018.
    What optional modules can be integrated into the system?
    Depending on the model, you can integrate optional modules such as a Built-in Filtration Module, Nitrogen Blow-Down Filtration Module, SPE Module for Veterinary Drug Residues, Integrated Salt Addition Module, Chilled Extract Storage Module, and an Internal Standard (ISTD) Addition Module.
    What is the difference in throughput and efficiency among the models?
    Throughput ranges from 32 samples per batch (HRH-Q32) up to 120 samples per batch (HRH-Q120). Testing efficiency varies from approximately 2.7 minutes per sample on the high-throughput HRH-Q120 to 5.5 minutes per sample on standard models.

    Make An AppointmentLEAVE YOUR MESSAGE