Fully Automated QuEChERS System - Efficient Pesticide Analysis Suppliers & Factory in China
Application
QuEChERS sample preparation on plant-origin food, herbs, tobacco and imported & exported agricultural products, tea and herbs, etc.
Components
Features
Fully Automated Design
The system established a standard preparation process for QuEChERS method. After placing samples and test tubes, the system can carry out actions automatically such as oscillating, vortexing, centrifugating, and pipetting.
Automated Salt and Ceramic Homogenizer Feeding
The user-defined system can realize automatic and accurate feeding of mixed salt.
Oscillating Compatibility
Four test tubes oscillate simultaneously with adjustable speed and time. The structure is compatible with 50ml/15ml test tubes.
Horizontal Centrifuge Module
Integrate 4-rotor horizontal centrifuge and is compatible with 50ml/15ml test tubes simultaneously, with adjustable centrifugal time and speed.
Dual-channel Vortex Module
Each channel is driven independently and vortex time is adjustable.
High-precision Pipetting Robot Arm
Integrate high-precision pipetting module with precise liquid-level detection.
Automated Tip Replacement
Replace tips for each pipetting to avoid cross-contamination.
Intelligent Syringe Pump
Equipped with 4-way or 8-way switching valve, which can fully meet liquid filling requirements in routine tests. Real-time tube-level monitoring guarantees pipetting accuracy and reliability.
Ice Bath
Meet requirements of the Pharmacopoeia.
Fault Monitoring
Can monitor real-time failures of centrifugal weight match, cap screw/unscrew, tube delivering, ceramic homogenizer feeding, and other failures during operation, and feedback to the user interface in time.
Remote Monitoring
Monitor software main interface and real-time internal operation remotely via mobile phone and computer.
Module Integration
Supports integration with automated filtration modules or nitrogen blow filtration modules.
HMI (Human Machine Interface)
Easy operation, real-time display status of function modules and procedure of online testing.
Test procedure is built-in and can be used directly, including pesticide residue QuEChERS preparation. Program parameters can be adjusted per requirements.
Supports remote control and real-time process monitoring via smart terminals.
Specification
Item |
Technical Parameters |
|||||
Model |
HRH-Q32 |
HRH-Q40 |
HRH-Q60 |
HRH-Q40PRO |
HRH-Q60PRO |
HRH-Q120 |
Sample Throughput |
32 /batch |
40 /batch |
60 /batch |
40 /batch |
60 /test |
120 /batch |
Test Efficiency |
Est. 5min/sample, total 2hrs. 40min |
Est. 5.5min/sample, total 3hrs. 40min |
Est. 5.5min/sample, total 5hrs. 25min |
Est. 5min/sample, total 3hrs. 20min |
Est. 4.7min/sample, total 4hrs. 40min |
Est. 2.7min/sample, total 5hrs. 20min |
Filling Acc. |
≤0.5% RSD, 4-way switch valve |
≤0.5% RSD, 8-way switch valve |
||||
Pipetting Acc. |
Vol.≤5ml, Acc.≤1% RSD |
Vol.≤1ml, Acc.≤1% RSD |
Vol.≤5ml, Acc.≤1% RSD |
|||
| Salt Adding Acc. | ≤5%RSD |
|
||||
| Shaking |
4 stations, 0-500 RPM, speed and time adjustable |
8 stations, 0-500 RPM, speed and time adjustable |
8 stations, 0-1000RPM, speed and time adjustable |
|||
| Vortex Speed | 2 stations, ≥3500RPM |
8 stations, ≥3500RPM |
||||
| Centrifuge Speed | 0-5000 RPM, speed and time adjustable |
|||||
| Ice Bath Acc. | / |
±1℃ |
||||
| Centrifuge Throughput | 4 stations, compatible with 50ml/15ml tubes |
8 stations, compatible with 50ml/15ml tubes |
||||
| Power Supply | 220VAC 50Hz or customized |
|||||
| Dimensions | 1270×910×2100mm |
1480×910×2100mm |
2440×1010×2150mm |
|||
Configuration
| Type | Items | Quantity |
|---|---|---|
| Standard | Host | 1 set |
| Industrial Controlled PC | 1 set | |
| Air Compressor | 1 set | |
| Dedicated Control Software | 1 set | |
| Φ6 PU Tube | 3m | |
| 50mL Test Tube | 1 bag | |
| 15mL Test Tube | 2 bags | |
| 1mL Pipette Tip (HRH-Q40, HRH-Q60) | 2 boxes | |
| 5mL Pipette Tip (HRH-Q32, HRH-Q40PRO, HRH-Q60PRO, HRH-Q120) | 2 boxes | |
| Ceramic Homogenizer | 100 pcs | |
| Certificate, Warranty Card, User Manual | 1 set | |
| Optional | Built-in Filtration Module (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) | 1 set |
| Nitrogen Blow-Down Filtration Module (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) | 1 set | |
| SPE Module for Veterinary Drug Residues (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) | 1 set | |
| Integrated Salt Addition Module (for HRH-Q120 only) | 1 set | |
| Chilled Extract Storage Module (for HRH-40PRO, HRH-60PRO only) | 1 set | |
| Internal Standard (ISTD) Addition Module | 1 set | |
| Multi-protocol Processing (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) | 1 set |
Compliance Standards
-
GB 23200.113—2026 National Food Safety Standard Determination of 242 Pesticides and Metabolites Residues in Foods of Plant Origin - Gas Chromatography-tandem Mass Spectrometry Method.
-
GB 23200.121—2026 National food safety standard—Determination of 352 pesticides and metabolites residues in foods of plant origin—Liquid chromatography-tandem mass spectrometry method.
-
Pharmacopoeia of the People's Republic of China 2025 Edition (Volume IV), 2341 – Method 4 for the Determination of Pesticide Multiresidues: Determination of Pesticide Multiresidues (Mass Spectrometry); Method 5: Determination of Prohibited Pesticide Multiresidues in Medicinal Materials and Decoction Pieces (Botanical).
-
AOAC 2007.01 Determination of pesticide residues in food using acetonitrile extraction and magnesium sulfate separation.
-
EN 15662:2018 Foods of plant origin - Multimethod for the determination of pesticide residues using GC- and LC-based analysis following acetonitrile extraction/partitioning and clean-up by dispersive SPE - Modular QuEChERS-method.
Frequently Asked Questions (FAQ)
What is the primary application of the Fully Automated QuEChERS System?
The system is designed for automated QuEChERS sample preparation on plant-origin food, herbs, tobacco, tea, and imported & exported agricultural products to facilitate pesticide and veterinary drug residue analysis.
How does the system prevent cross-contamination during sample processing?
It features an automated tip replacement mechanism, replacing pipetting tips for each sample to fully avoid carryover and cross-contamination.
Can the extraction process be monitored remotely?
Yes. The system supports multi-terminal remote monitoring, allowing operators to oversee the software's main interface and operation status in real time via mobile phones or computers.
What international standards does this system comply with?
The system complies with major standards including AOAC 2007.01, EN 15662:2018, GB 23200.113—2026, GB 23200.121—2026, and the 2025 Edition of the Chinese Pharmacopoeia.
What optional modules are available for the system?
Optional configurations include built-in filtration modules, nitrogen blow-down filtration modules, SPE modules for veterinary drug residues, integrated salt addition modules, chilled extract storage modules, and internal standard (ISTD) addition modules.
What is the sample throughput capacity of the system?
Depending on the model chosen, the system can handle batch sizes of 32, 40, 60, or up to 120 samples per batch/test.