Request a Quote
Leave Your Message

Fully Automated QuEChERS System for Pesticide Residue Analysis – Efficient China Suppliers & Factory Solutions

,

The QuEChERS pesticide residue preparation method is highly regarded for its efficiency; however, traditional methods can be labor-intensive, prone to errors, and lack reproducibility, especially with larger sample volumes. Our fully automatic QuEChERS system, designed by leading suppliers in China, streamlines the process by integrating essential functions including automated liquid/salt/ceramic homogenizer feeding, oscillating, vortexing, centrifuging, ice bath cooling, and precision pipetting. Capable of processing 32, 40, 60, or even 120 samples in a single test, this innovative solution minimizes manual intervention, thereby reducing the risk of human error. As a result, it ensures greater accuracy and stability in detection, facilitating fully automated analysis that significantly boosts testing efficiency. Partner with our factory for cutting-edge automation in pesticide residue analysis.

,

    Application

    QuEChERS sample preparation on plant-origin food, herbs, tobacco and imported & exported agricultural products, tea and herbs, etc.

    Components
    Fully Automated QuEChERS System (1)
    Features
    01 Fully Automated Design

    The system established a standard preparation process for QuEChERS method. After placing samples and test tubes, the system can carry out actions automatically such as oscillating, vortexing, centrifugating, and pipetting.

    02 Automated Salt and Ceramic Homogenizer Feeding

    The user-defined system can realize automatic and accurate feeding of mixed salt.

    03 Oscillating Compatibility

    Four test tubes oscillate simultaneously with adjustable speed and time. The structure is compatible with 50ml/15ml test tubes.

    04 Horizontal Centrifuge Module

    Integrate 4-rotor horizontal centrifuge and is compatible with 50ml/15ml test tubes simultaneously, with adjustable centrifugal time and speed.

    05 Dual-channel Vortex Module

    Each channel is driven independently and vortex time is adjustable.

    06 High-precision Pipetting Robot Arm

    Integrate high-precision pipetting module with precise liquid-level detection.

    07 Automated Tip Replacement

    Replace tips for each pipetting to avoid cross-contamination.

    08 Intelligent Syringe Pump

    Equipped with 4-way or 8-way switching valve, which can fully meet liquid filling requirements in routine tests. Real-time tube-level monitoring guarantees pipetting accuracy and reliability.

    09 Ice Bath

    Meet requirements of the Pharmacopoeia.

    10 Multi-directional Fault Monitoring

    Can monitor real-time failures of centrifugal weight match, cap screw/unscrew, tube delivering, ceramic homogenizer feeding, and other failures during operation, and feedback to the user interface in time.

    11 Multi-terminal Remote Monitoring

    Monitor software main interface and real-time internal operation remotely via mobile phone and computer.

    12 Modular Integration Support

    Supports integration with automated filtration modules or nitrogen blow filtration modules.

    HMI
    1. Main Interface: Easy operation, real-time display status of function modules and procedure of online testing.
    Fully Automated QuEChERS System (2)
    2. Program Setting Interface: Built-in test procedure, including pesticide residue QuEChERS preparation for vegetables, fruits, cereals and nuts. Parameters can be adjusted per actual requirements.
    Fully Automated QuEChERS System (3)
    3. Remote Monitor: Real-time internal operation and software main interface monitoring remotely via mobile phone and computer.
    Fully Automated QuEChERS System (4)
    Specification
    Item Technical Parameters
    Model HRH-Q32 HRH-Q40 HRH-Q60 HRH-Q40PRO HRH-Q60PRO HRH-Q120
    Sample Throughput 32 /batch 40 /batch 60 /batch 40 /batch 60 /test 120 /batch
    Test Efficiency Est. 5min/sample, total 2hrs. 40min Est. 5.5min/sample, total 3hrs. 40min Est. 5.5min/sample, total 5hrs. 25min Est. 5min/sample, total 3hrs. 20min Est. 4.7min/sample, total 4hrs. 40min Est. 2.7min/sample, total 5hrs. 20min
    Filling Acc. ≤0.5% RSD, 4-way switch valve ≤0.5% RSD, 8-way switch valve
    Pipetting Acc. Vol.≤5ml, Acc.≤1% RSD Vol.≤1ml, Acc.≤1% RSD Vol.≤5ml, Acc.≤1% RSD
    Salt Adding Acc. ≤5%RSD 1. Salt bin: ≤5%RSD
    2. Individual salt tube
    Shaking 4 stations, 0-500 RPM, speed and time adjustable 8 stations, 0-500 RPM, speed and time adjustable 8 stations, 0-1000RPM, speed and time adjustable
    Vortex Speed 2 stations, ≥3500RPM 8 stations, ≥3500RPM
    Centrifuge Speed 0-5000 RPM, speed and time adjustable
    Ice Bath Acc. / ±1℃
    Centrifuge Throughput 4 stations, compatible with 50ml/15ml tubes 8 stations, compatible with 50ml/15ml tubes
    Power Supply 220VAC 50Hz or customized
    Dimensions 1270×910×2100mm 1480×910×2100mm 2440×1010×2150mm
    Configuration
    Type Items Quantity
    Standard Host 1 set
    Industrial Controlled PC 1 set
    Air Compressor 1 set
    Dedicated Control Software 1 set
    Φ6 PU Tube 3m
    50mL Test Tube 1 bag
    15mL Test Tube 2 bags
    1mL Pipette Tip (HRH-Q40, HRH-Q60) 2 boxes
    5mL Pipette Tip (HRH-Q32, HRH-Q40PRO, HRH-Q60PRO, HRH-Q120) 2 boxes
    Ceramic Homogenizer 100 pcs
    Certificate, Warranty Card, User Manual 1 set
    Optional Built-in Filtration Module (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) 1 set
    Nitrogen Blow-Down Filtration Module (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) 1 set
    SPE Module for Veterinary Drug Residues (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) 1 set
    Integrated Salt Addition Module (for HRH-Q120 only) 1 set
    Chilled Extract Storage Module (for HRH-40PRO, HRH-60PRO only) 1 set
    Internal Standard (ISTD) Addition Module 1 set
    Multi-protocol Processing (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) 1 set
    Compliance
    GB 23200.113—2026 National Food Safety Standard Determination of 242 Pesticides and Metabolites Residues in Foods of Plant Origin - Gas Chromatography-tandem Mass Spectrometry Method.
    GB 23200.121—2026 National food safety standard—Determination of 352 pesticides and metabolites residues in foods of plant origin—Liquid chromatography-tandem mass spectrometry method.
    Pharmacopoeia of the People's Republic of China 2025 Edition (Volume IV), 2341 – Method 4 for the Determination of Pesticide Multiresidues: Determination of Pesticide Multiresidues (Mass Spectrometry); Method 5: Determination of Prohibited Pesticide Multiresidues in Medicinal Materials and Decoction Pieces (Botanical).
    AOAC 2007.01 Determination of pesticide residues in food using acetonitrile extraction and magnesium sulfate separation.
    EN 15662:2018 Foods of plant origin - Multimethod for the determination of pesticide residues using GC- and LC-based analysis following acetonitrile extraction/partitioning and clean-up by dispersive SPE - Modular QuEChERS-method.
    Frequently Asked Questions (FAQ)
    What is the primary application of this Fully Automated QuEChERS System?

    The system is designed for automated QuEChERS sample preparation on plant-origin food, herbs, tobacco, tea, and imported & exported agricultural products.

    How does the system prevent cross-contamination during pipetting?

    The system features an automated tip replacement module that replaces the pipette tips for each sample processing cycle to prevent cross-contamination.

    Which standard regulations and pharmacopoeia methods does the system comply with?

    It complies with GB 23200.113-2026, GB 23200.121-2026, the 2025 Edition of the Pharmacopoeia of the People's Republic of China (Volume IV, Method 2341), AOAC 2007.01, and EN 15662:2018.

    Can I monitor the preparation process remotely?

    Yes, the system supports multi-terminal remote monitoring, allowing users to track the software main interface and real-time internal operations via mobile phones and computers.

    What is the sample throughput capacity across different models?

    Depending on the model, sample throughput ranges from 32 samples per batch (Model HRH-Q32) up to 120 samples per batch (Model HRH-Q120).

    What optional modules can be integrated into the system?

    Optional modules include Built-in Filtration, Nitrogen Blow-Down Filtration, SPE Module for Veterinary Drug Residues, Integrated Salt Addition, Chilled Extract Storage, Internal Standard (ISTD) Addition, and Multi-protocol Processing.

    Make An AppointmentLEAVE YOUR MESSAGE