Fully Automated QuEChERS System for Pesticide Residue Analysis - Reliable Suppliers and Factory in China
Application
QuEChERS sample preparation on plant-origin food, herbs, tobacco and imported & exported agricultural products, tea and herbs, etc.
Components
Features
Establishes a standard preparation process for the QuEChERS method. After placing samples and test tubes, the system automatically carries out oscillating, vortexing, centrifugating, and pipetting.
The user-defined system realizes automatic and accurate feeding of mixed salt.
Four test tubes oscillate simultaneously with adjustable speed and time. The structure is compatible with both 50ml and 15ml test tubes.
Integrates a 4-rotor horizontal centrifuge compatible with 50ml/15ml test tubes simultaneously, with adjustable centrifugal time and speed.
Each channel is driven independently and the vortex time is adjustable.
Integrates a high-precision pipetting module equipped with precise liquid-level detection.
Replaces tips automatically for each pipetting cycle to completely avoid cross-contamination.
Equipped with a 4-way or 8-way switching valve to meet liquid filling requirements in routine tests. Real-time tube-level monitoring guarantees pipetting accuracy.
Meets the temperature control requirements of the Pharmacopoeia.
Monitors real-time failures of centrifugal weight match, cap screw/unscrew, tube delivering, ceramic homogenizer feeding, and feeds back to the user interface.
Allows users to monitor the software main interface and real-time internal operations remotely via mobile phone and computer.
Supports integration with automated filtration modules or nitrogen blow filtration modules.
HMI (Human-Machine Interface)
Easy operation, real-time display status of function modules and procedure of online testing.
Built-in test procedures (vegetables, fruits, cereals, nuts) ready for direct use. Parameters can be optimized per actual requirements or adjusted partially under manufacturer guidance.
Real-time status tracking and remote operation control via terminal devices.
Specification
| Item | Technical Parameters | |||||
|---|---|---|---|---|---|---|
| Model | HRH-Q32 | HRH-Q40 | HRH-Q60 | HRH-Q40PRO | HRH-Q60PRO | HRH-Q120 |
| Sample Throughput | 32 /batch | 40 /batch | 60 /batch | 40 /batch | 60 /test | 120 /batch |
| Test Efficiency | Est. 5min/sample, total 2hrs. 40min | Est. 5.5min/sample, total 3hrs. 40min | Est. 5.5min/sample, total 5hrs. 25min | Est. 5min/sample, total 3hrs. 20min | Est. 4.7min/sample, total 4hrs. 40min | Est. 2.7min/sample, total 5hrs. 20min |
| Filling Acc. | ≤0.5% RSD, 4-way switch valve | ≤0.5% RSD, 8-way switch valve | ||||
| Pipetting Acc. | Vol.≤5ml, Acc.≤1% RSD | Vol.≤1ml, Acc.≤1% RSD | Vol.≤5ml, Acc.≤1% RSD | |||
| Salt Adding Acc. | ≤5%RSD | 1. Salt bin: ≤5%RSD 2. Individual salt tube |
||||
| Shaking | 4 stations, 0-500 RPM, speed/time adjustable | 8 stations, 0-500 RPM, speed/time adjustable | 8 stations, 0-1000RPM, speed/time adjustable | |||
| Vortex Speed | 2 stations, ≥3500RPM | 8 stations, ≥3500RPM | ||||
| Centrifuge Speed | 0-5000 RPM, speed and time adjustable | |||||
| Ice Bath Acc. | / | ±1℃ | ||||
| Centrifuge Throughput | 4 stations, compatible with 50ml/15ml tubes | 8 stations, compatible with 50ml/15ml tubes | ||||
| Power Supply | 220VAC 50Hz or customized | |||||
| Dimensions | 1270×910×2100mm | 1480×910×2100mm | 2440×1010×2150mm | |||
Configuration
| Type | Description | Qty / Unit |
|---|---|---|
| Standard | Host | 1 set |
| Industrial Controlled PC | 1 set | |
| Air Compressor | 1 set | |
| Dedicated Control Software | 1 set | |
| Φ6 PU Tube | 3m | |
| 50mL Test Tube | 1 bag | |
| 15mL Test Tube | 2 bags | |
| 1mL Pipette Tip (HRH-Q40, HRH-Q60) | 2 boxes | |
| 5mL Pipette Tip (HRH-Q32, HRH-Q40PRO, HRH-Q60PRO, HRH-Q120) | 2 boxes | |
| Ceramic Homogenizer | 100 pcs | |
| Certificate, Warranty Card, User Manual | 1 set | |
| Optional | Built-in Filtration Module (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) | 1 set |
| Nitrogen Blow-Down Filtration Module (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) | 1 set | |
| SPE Module for Veterinary Drug Residues (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) | 1 set | |
| Integrated Salt Addition Module (for HRH-Q120 only) | 1 set | |
| Chilled Extract Storage Module (for HRH-40PRO, HRH-60PRO only) | 1 set | |
| Internal Standard (ISTD) Addition Module | 1 set | |
| Multi-protocol Processing (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) | 1 set |
Compliance
- GB 23200.113—2026 National Food Safety Standard Determination of 242 Pesticides and Metabolites Residues in Foods of Plant Origin - Gas Chromatography-tandem Mass Spectrometry Method.
- GB 23200.121—2026 National food safety standard—Determination of 352 pesticides and metabolites residues in foods of plant origin—Liquid chromatography-tandem mass spectrometry method.
- Pharmacopoeia of the People's Republic of China 2025 Edition (Volume IV), 2341 – Method 4 for the Determination of Pesticide Multiresidues (Mass Spectrometry); Method 5: Determination of Prohibited Pesticide Multiresidues in Medicinal Materials and Decoction Pieces (Botanical).
- AOAC 2007.01 Determination of pesticide residues in food using acetonitrile extraction and magnesium sulfate separation.
- EN 15662:2018 Foods of plant origin - Multimethod for the determination of pesticide residues using GC- and LC-based analysis following acetonitrile extraction/partitioning and clean-up by dispersive SPE - Modular QuEChERS-method.
Frequently Asked Questions (FAQ)
What sample matrices are suitable for this automated system?
The system is designed for QuEChERS sample preparation on plant-origin food, herbs, tobacco, tea, and imported & exported agricultural products.
How does the system prevent cross-contamination during liquid handling?
It features an automated tip replacement function that replaces pipette tips for each pipetting process, effectively avoiding cross-contamination.
What tube sizes are compatible with the oscillating and centrifuge modules?
Both the oscillating structure and the horizontal centrifuge module are compatible with standard 50ml and 15ml test tubes simultaneously.
Can I monitor the preparation process remotely?
Yes, the system supports multi-terminal remote monitoring. You can track the software interface and real-time internal operations via mobile phone or computer.
What international standards does the system comply with?
The system is compliant with major standards including AOAC 2007.01, EN 15662:2018, Chinese Pharmacopoeia 2025 Edition, and GB 23200.113 / GB 23200.121 (2026 standards).
Are there optional modules available for veterinary drug residue testing?
Yes, an optional SPE Module for Veterinary Drug Residues is available for specific models (HRH-40PRO, HRH-60PRO, and HRH-Q120).