Request a Quote
Leave Your Message

Fully Automated QuEChERS System for Pesticide Residue Analysis - Top China Suppliers & Factory Solutions

The fully automated QuEChERS pesticide residue preparation system represents a significant advancement for laboratories dealing with large sample quantities. Unlike traditional methods, which are labor-intensive and prone to errors, this innovative solution streamlines the entire process. Designed by leading China suppliers, our factory has integrated multiple functions including automated liquid, salt, and ceramic homogenizer feeding, oscillating, vortexing, centrifuging, ice bath management, and precision pipetting. Capable of processing 32, 40, 60, or even 120 samples in a single run, this system not only minimizes manual involvement but also enhances accuracy and reproducibility. Eliminate the risk of human error and boost your testing efficiency with our state-of-the-art technology, ensuring precise detection and consistent results

    Features

    Fully Automated Design

    The system established a standard preparation process for QuEChERS method. After placing samples and test tubes, the system can carry out actions automatically such as oscillating, vortexing, centrifugating, and pipetting.

    Automated Salt & Homogenizer Feeding

    The user-defined system can realize automatic and accurate feeding of mixed salt.

    Oscillating Compatibility

    Four test tubes oscillate simultaneously with adjustable speed and time. The structure is compatible with 50ml/15ml test tubes.

    Horizontal Centrifuge Module

    Integrate 4-rotor horizontal centrifuge and is compatible with 50ml/15ml test tubes simultaneously, with adjustable centrifugal time and speed.

    Dual-channel Vortex Module

    Each channel is driven independently and vortex time is adjustable.

    High-precision Pipetting Robot Arm

    Integrate high-precision pipetting module with precise liquid-level detection.

    Automated Tip Replacement

    Replace tips for each pipetting to avoid cross-contamination.

    Intelligent Syringe Pump

    Equipped with 4-way or 8-way switching valve, which can fully meet liquid filling requirements in routine tests. Real-time tube-level monitoring guarantees pipetting accuracy and reliability.

    Ice Bath

    Meet requirements of ChP2020.

    Multi-directional Fault Monitoring

    Can monitor real-time failures of centrifugal weight match, cap screw/unscrew, tube delivering, ceramic homogenizer feeding, and other failures during operation, and feedback to the user interface in time.

    Multi-terminal Remote Monitoring

    Monitor software main interface and real-time internal operation remotely via mobile phone and computer.

    System Integration

    Supports integration with automated filtration modules or nitrogen blow filtration modules.

    Components

    Fully Automated QuEChERS System Components

    Application

    QuEChERS sample preparation on plant-origin food, herbs, tobacco and imported & exported agricultural products, tea and herbs, etc.

    HMI (Human Machine Interface)

    1. Main Interface

    Easy operation, real-time display status of function modules and procedure of online testing.

    Main Interface Display

    2. Program Setting Interface

    Test procedure is built-in and can be used directly, including pesticide residue QuEChERS preparation for vegetables and fruits, cereals and nuts. Program parameters can be adjusted and optimized per actual requirements, and also can be adjusted partially or by user design under guidance of manufacturer.

    Program Setting Interface

    3. Remote Monitor

    Real-time remote software and operations monitoring.

    Remote Monitor Display

    Technical Specifications

    Item Technical Parameters
    Model HRH-Q32 HRH-Q40 HRH-Q60 HRH-Q40PRO HRH-Q60PRO HRH-Q120
    Sample Throughput 32 /test 40 /test 60 /test 40 /test 60 /test 120 /test
    Test Efficiency Est. 5min/sample, total 2hrs. 40min Est. 5.5min/sample, total 3hrs. 40min Est. 5.5min/sample, total 5hrs. 25min Est. 5min/sample, total 3hrs. 20min Est. 4.7min/sample, total 4hrs. 40min Est. 2.7min/sample, total 5hrs. 20min
    Filling Acc. ≤0.5% RSD, 4-way switch valve ≤0.5% RSD, 8-way switch valve
    Pipetting Acc. Vol.≤5ml, Acc.≤1% RSD Vol.≤1ml, Acc.≤1% RSD Vol.≤5ml, Acc.≤1% RSD
    Salt Adding Acc. ≤5%RSD 1. Salt bin: ≤5%RSD
    2. Individual salt tube
    Shaking 4 stations, 0-500 RPM, speed/time adjustable 8 stations, 0-500 RPM, speed/time adjustable 8 stations, 0-1000RPM, speed/time adjustable
    Vortex Speed 2 stations, ≥3500RPM 8 stations, ≥3500RPM
    Centrifuge Speed 0-5000 RPM, speed and time adjustable
    Ice Bath Acc. / ±1℃
    Centrifuge Throughput 4 stations, compatible with 50ml/15ml tubes 8 stations, compatible with 50ml/15ml tubes
    Power Supply 220VAC 50Hz or customized
    Dimensions 1270×910×2100mm 1480×910×2100mm 2440×1010×2150mm

    Configuration

    Type Standard Items Quantity
    Standard Host 1 set
    Industrial Controlled PC 1 set
    Air Compressor 1 set
    Dedicated Control Software 1 set
    Φ6 PU Tube 3m
    50ml Test Tube 1 bag (100 tubes)
    15ml Test Tube 2 bags (100 tubes)
    1ml Tip (HRH-Q40, HRH-Q60) 2 boxes (392 tips)
    5ml Tip (HRH-Q32, HRH-Q40PRO, HRH-Q60PRO, HRH-Q120) 2 boxes (100 tips)
    Ceramic Homogenizer 100 pcs
    Certificate, Warranty Card, User Manual 1 set
    Optional Built-in filtration module (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) 1 set
    Nitrogen evaporation & filtration system (930×910×2100 mm) (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) 1 set
    Veterinary drug residue column-based SPE module (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) 1 set
    Integrated salting out module (for HRH-Q120 only) 1 set
    Finished sample refrigeration module (for HRH-40PRO, HRH-60PRO only) 1 set
    Internal standard addition module (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) 1 set
    Multi-protocol operation (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) 1 set

    Compliance Standards

    GB 23200.113—2026 National Food Safety Standard Determination of 242 Pesticides and Metabolites Residues in Foods of Plant Origin - Gas Chromatography-tandem Mass Spectrometry Method.

    GB 23200.121—2026 National food safety standard—Determination of 352 pesticides and metabolites residues in foods of plant origin—Liquid chromatography-tandem mass spectrometry method.

    Pharmacopoeia of the People's Republic of China 2025 Edition (Volume IV), 2341 – Method 4 for the Determination of Pesticide Multiresidues: Determination of Pesticide Multiresidues (Mass Spectrometry); Method 5: Determination of Prohibited Pesticide Multiresidues in Medicinal Materials and Decoction Pieces (Botanical).

    AOAC 2007.01 Determination of pesticide residues in food using acetonitrile extraction and magnesium sulfate separation.

    EN 15662:2018 Foods of plant origin - Multimethod for the determination of pesticide residues using GC- and LC-based analysis following acetonitrile extraction/partitioning and clean-up by dispersive SPE - Modular QuEChERS-method.

    Frequently Asked Questions (FAQ)

    What applications is the Fully Automated QuEChERS System suitable for?
    The system is designed for QuEChERS sample preparation on plant-origin food, herbs, tobacco, imported and exported agricultural products, tea, and other similar matrices.
    How does the system prevent cross-contamination during automated pipetting?
    The system features a high-precision pipetting robot arm integrated with an automated tip replacement mechanism. Tips are replaced for each individual pipetting procedure to thoroughly avoid cross-contamination.
    What sample throughput options are available?
    We offer various models to fit different laboratory scales: HRH-Q32 (32 tests), HRH-Q40 and HRH-Q40PRO (40 tests), HRH-Q60 and HRH-Q60PRO (60 tests), and the high-throughput HRH-Q120 (120 tests per run).
    Does the system support remote operations monitoring?
    Yes, it features multi-terminal remote monitoring capability. Users can monitor the main software interface and real-time internal operations remotely via mobile phones and computers.
    Which regulatory standards does this QuEChERS system comply with?
    The system complies with major national and international methods, including GB 23200.113-2026, GB 23200.121-2026, Pharmacopoeia of the People's Republic of China (2025 Edition, Volume IV), AOAC 2007.01, and EN 15662:2018.
    What optional modules can be integrated into the system?
    Depending on the model, you can integrate optional modules such as a built-in filtration module, nitrogen evaporation & filtration system, column-based SPE module for veterinary drug residues, salting out module, finished sample refrigeration module, and an internal standard addition module.