Request a Quote
Leave Your Message

Fully Automated QuEChERS System from China Suppliers and Factory for Efficient Pesticide Residue Analysis

Introducing our fully automated QuEChERS pesticide residue preparation system, designed to enhance efficiency and accuracy for large sample sizes. While the traditional QuEChERS method is widely used, it often falls short due to labor intensity, high error rates, and poor reproducibility. Our advanced system integrates multiple functions, including automatic liquid, salt, and ceramic homogenizer feeding, oscillating, vortexing, centrifuging, an ice bath, and precision pipetting. Capable of handling 32, 40, 60, or even 120 samples in a single test, this innovative solution minimizes the need for personnel involvement, significantly reducing manual errors. By ensuring precision and stability in detection, this fully automated system revolutionizes pesticide analysis. As a leading China supplier and factory, we are committed to providing cutting-edge technology that streamlines your testing processes and enhances overall test efficiency

    Features

    1. Fully Automated Design: The system established a standard preparation process for QuEChERS method. After placing samples and test tubes, the system can carry out actions automatically such as oscillating, vortexing, centrifugating, and pipetting.

    2. Automated Salt and Ceramic Homogenizer Feeding: The user-defined system can realize automatic and accurate feeding of mixed salt.

    3. Oscillating Compatibility: Four test tubes oscillate simultaneously with adjustable speed and time. The structure is compatible with 50ml/15ml test tubes.

    4. Horizontal Centrifuge Module: Integrate 4-rotor horizontal centrifuge and is compatible with 50ml/15ml test tubes simultaneously, with adjustable centrifugal time and speed.

    5. Dual-channel Vortex Module: Each channel is driven independently and vortex time is adjustable.

    6. High-precision Pipetting Robot Arm: Integrate high-precision pipetting module with precise liquid-level detection.

    7. Automated Tip Replacement: Replace tips for each pipetting to avoid cross-contamination.

    8. Intelligent Syringe Pump: Equipped with 4-way or 8-way switching valve, which can fully meet liquid filling requirements in routine tests. Real-time tube-level monitoring guarantees pipetting accuracy and reliability.

    9. Ice Bath: Meet requirements of ChP2020.

    10. Multi-directional Fault Monitoring: Can monitor real-time failures of centrifugal weight match, cap screw/unscrew, tube delivering, ceramic homogenizer feeding, and other failures during operation, and feedback to the user interface in time.

    11. Multi-terminal Remote Monitoring: Monitor software main interface and real-time internal operation remotely via mobile phone and computer.

    12. Supports Integration: Supports integration with automated filtration modules or nitrogen blow filtration modules.

    Components

    Fully Automated QuEChERS System Components

    Application

    QuEChERS sample preparation on plant-origin food, herbs, tobacco and imported & exported agricultural products, tea and herbs, etc.

    HMI (Human-Machine Interface)

    1. Main Interface: Easy operation, real-time display status of function modules and procedure of online testing.

    HMI Main Interface

    2. Program Setting Interface: Test procedure is built-in and can be used directly, including pesticide residue QuEChERS preparation for vegetables and fruits, cereals and nuts. Program parameters can be adjusted and optimized per actual requirements, and also can be adjusted partially or by user design under guidance of manufacturer.

    HMI Program Setting Interface

    3. Remote Monitor: Real-time remote system observation.

    HMI Remote Monitor

    Specification

    Item Technical Parameters
    Model HRH-Q32 HRH-Q40 HRH-Q60 HRH-Q40PRO HRH-Q60PRO HRH-Q120
    Sample Throughput 32 /test 40 /test 60 /test 40 /test 60 /test 120 /test
    Test Efficiency Est. 5min/sample, total 2hrs. 40min Est. 5.5min/sample, total 3hrs. 40min Est. 5.5min/sample, total 5hrs. 25min Est. 5min/sample, total 3hrs. 20min Est. 4.7min/sample, total 4hrs. 40min Est. 2.7min/sample, total 5hrs. 20min
    Filling Acc. ≤0.5% RSD, 4-way switch valve ≤0.5% RSD, 8-way switch valve
    Pipetting Acc. Vol.≤5ml, Acc.≤1% RSD Vol.≤1ml, Acc.≤1% RSD Vol.≤5ml, Acc.≤1% RSD
    Salt Adding Acc. ≤5%RSD 1. Salt bin: ≤5%RSD
    2. Individual salt tube
    Shaking 4 stations, 0-500 RPM, speed and time adjustable 8 stations, 0-500 RPM, speed and time adjustable 8 stations, 0-1000RPM, speed and time adjustable
    Vortex Speed 2 stations, ≥3500RPM 8 stations, ≥3500RPM
    Centrifuge Speed 0-5000 RPM, speed and time adjustable
    Ice Bath Acc. / ±1℃
    Centrifuge Throughput 4 stations, compatible with 50ml/15ml tubes 8 stations, compatible with 50ml/15ml tubes
    Power Supply 220VAC 50Hz or customized
    Dimensions 1270×910×2100mm 1480×910×2100mm 2440×1010×2150mm

    Configuration

    Type Item Details Quantity
    Standard Host 1 set
    Industrial Controlled PC 1 set
    Air Compressor 1 set
    Dedicated Control Software 1 set
    Φ6 PU Tube 3m
    50ml Test Tube 1 bag (100 tubes)
    15ml Test Tube 2 bags (100 tubes)
    1ml Tip (HRH-Q40, HRH-Q60) 2 boxes (392 tips)
    5ml Tip (HRH-Q32, HRH-Q40PRO, HRH-Q60PRO, HRH-Q120) 2 boxes (100 tips)
    Ceramic Homogenizer 100 pcs
    Certificate, Warranty Card, User Manual 1 set
    Optional Built-in filtration module (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) 1 set
    Nitrogen evaporation & filtration system (930×910×2100 mm) (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) 1 set
    Veterinary drug residue column-based SPE module (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) 1 set
    Integrated salting out module (for HRH-Q120 only) 1 set
    Finished sample refrigeration module (for HRH-40PRO, HRH-60PRO only) 1 set
    Internal standard addition module (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) 1 set
    Multi-protocol operation (for HRH-40PRO, HRH-60PRO, HRH-Q120 only) 1 set

    Compliance

    • GB 23200.113—2026 National Food Safety Standard Determination of 242 Pesticides and Metabolites Residues in Foods of Plant Origin - Gas Chromatography-tandem Mass Spectrometry Method.

    • GB 23200.121—2026 National food safety standard—Determination of 352 pesticides and metabolites residues in foods of plant origin—Liquid chromatography-tandem mass spectrometry method.

    • Pharmacopoeia of the People's Republic of China 2025 Edition (Volume IV), 2341 – Method 4 for the Determination of Pesticide Multiresidues: Determination of Pesticide Multiresidues (Mass Spectrometry); Method 5: Determination of Prohibited Pesticide Multiresidues in Medicinal Materials and Decoction Pieces (Botanical).

    • AOAC 2007.01 Determination of pesticide residues in food using acetonitrile extraction and magnesium sulfate separation.

    • EN 15662:2018 Foods of plant origin - Multimethod for the determination of pesticide residues using GC- and LC-based analysis following acetonitrile extraction/partitioning and clean-up by dispersive SPE - Modular QuEChERS-method.

    Frequently Asked Questions (FAQ)

    What are the main applications of the Fully Automated QuEChERS System?

    The system is primarily used for QuEChERS sample preparation on plant-origin food, herbs, tobacco, imported & exported agricultural products, tea, and other botanical matrices.

    How does the system ensure there is no cross-contamination during pipetting?

    The system features an Automated Tip Replacement module that replaces the pipette tips for each sample and pipetting cycle, eliminating any risk of cross-contamination.

    What models are available and what are their sample capacities?

    We offer various models depending on your throughput needs: HRH-Q32 (32 samples/test), HRH-Q40 & HRH-Q40PRO (40 samples/test), HRH-Q60 & HRH-Q60PRO (60 samples/test), and HRH-Q120 (120 samples/test).

    Can the system be monitored remotely?

    Yes, the system is designed with Multi-terminal Remote Monitoring, allowing you to monitor the main software interface and real-time operations via mobile phones and computers.

    Does the system support integration with external modules?

    Yes, it supports optional integrations such as built-in filtration modules, nitrogen evaporation & filtration systems, column-based SPE modules, salting out modules, and finished sample refrigeration modules depending on the model.

    Which testing regulations and standards does this system comply with?

    The system complies with global standards including GB 23200.113—2026, GB 23200.121—2026, the Pharmacopoeia of the People's Republic of China (2025 Edition), AOAC 2007.01, and EN 15662:2018.

    Make An AppointmentLEAVE YOUR MESSAGE