Request a Quote
Leave Your Message

Fully Automated QuEChERS Sample Preparation System

Though QuEChERS pesticide residue preparation method is widely employed, it is labor-intensive, inefficient, error-prone, and poorly reproducible when the sample quantity is large. Fully automatic QuEChERS system integrates multiple functions including automated liquid /salt /ceramic homogenizer feeding, oscillating, vortexing, centrifuging, ice bath, and precision pipetting. It can handle 32, 40, 60, 120 samples in a single test. With simple operation and no personnel involvement, it can avoid manual errors, ensure accuracy and stability of detection, realize fully automated detection, and improve test efficiency.

    Application

    QuEChERS sample preparation on plant-origin food, herbs, tobacco and imported & exported agricultural products, tea and herbs, etc.

    Components

    Fully Automated QuEChERS System (1)

    Features

    1. Fully Automated Design: the system established a standard preparation process for QuEChERS method. After placing samples and test tubes, the system can carry out actions automatically such as oscillating, vortexing, centrifugating, and pipetting.

    2. Automated Salt and Ceramic Homogenizer Feeding: the user-defined system can realize automatic and accurate feeding of mixed salt.

    3. Oscillating Compatibility: four test tubes oscillate simultaneously with adjustable speed and time. The structure is compatible with 50ml/15ml test tubes.

    4. Horizontal Centrifuge Module: integrate 4-rotor horizontal centrifuge and is compatible with 50ml/15ml test tubes simultaneously, with adjustable centrifugal time and speed.

    5. Dual-channel Vortex Module: each channel is driven independently and vortex time is adjustable.

    6. High-precision Pipetting Robot Arm: integrate high-precision pipetting module with precise liquid-level detection.

    7. Automated Tip Replacement: replace tips for each pipetting to avoid cross-contamination.

    8. Intelligent Syringe Pump: equipped with 4-way or 8-way switching valve, which can fully meet liquid filling requirements in routine tests. Real-time tube-level monitoring guarantees pipetting accuracy and reliability.

    9. Ice Bath: Meet requirements of the Pharmacopoeia .

    10. Multi-directional Fault Monitoring: can monitor real-time failures of centrifugal weight match, cap screw/unscrew, tube delivering, ceramic homogenizer feeding, and other failures during operation, and feedback to the user interface in time.

    11. Multi-terminal Remote Monitoring: monitor software main interface and real-time internal operation remotely via mobile phone and computer.

    12. Supports integration with automated filtration modules or nitrogen blow filtration modules.

    HMI

    1. Main Interface – Simple and intuitive operation buttons. Real-time status of each functional module and the progress of online experiments are displayed.

    Fully Automated QuEChERS System (2)

    2. Program Setting Interface: test procedure is built-in and can be used directly, including pesticide residue QuEChERS preparation for vegetables and fruits, cereals and nuts. Program parameters can be adjusted and optimized per actual requirements, and also can be adjusted partially or by user design under guidance of manufacturer.

    Fully Automated QuEChERS System (3)

    3. Remote Monitor

    Fully Automated QuEChERS System (4)

    Specification

    Item

    Technical Parameters

    Model

    HRH-Q32

    HRH-Q40PRO

    HRH-Q60PRO

    HRH-Q120

    Sample Throughput

    32 /batch

    40 /batch

    60 /batch

    120 /batch

    Test Efficiency

    Est. 6min/sample, total 3hrs. 15min

    Est. 5min/sample, total 3hrs. 20min

    Est. 5min/sample, total 5hrs

    Est. 2.5min/sample, total 5hrs

    Filling Acc.

    ≤0.5% RSD, 4-way switch valve

    ≤0.5% RSD, 8-way switch valve

    Pipetting Acc.

    Vol.≤5ml, Acc.≤1% RSD

    Vol.≤5ml, Acc.≤1% RSD

    Salt Adding Acc.

    ≤5%RSD

    1. Salt bin: ≤5%RSD
    2. Or individual salt tubes
    Shaking

    4 stations, 0-500 RPM,

    speed and time adjustable

    8 stations, 0-500 RPM, speed and time adjustable

    8 stations,

    0-1000RPM, speed and time adjustable

    Vortex

    2 stations, ≥3500RPM

    8 stations, ≥3500RPM

    Centrifuge Speed

    0-5000 RPM, speed and time adjustable

    Ice Bath Acc.

    /

    ±1℃

    Centrifuge Throughput

    4 stations, compatible with 50ml/15ml tubes

    8 stations, compatible with 50ml/15ml tubes

    Power Supply

    220VAC 50Hz or customized

    Dimensions

    1270×910×2100mm

    1480×910×2100mm

    2440×1010×2150mm

    Configuration

    Standard
    Configuration
    Host 1 unit
    Air Compressor 1 unit
    Dedicated Control Software 1 set
    50mL Test Tube (100/pack) 1 pack
    15mL Test Tube  (50/pack) 2 packs
    5mL Pipette Tip (HRH-Q32, HRH-Q40PRO, HRH-Q60PRO, HRH-Q120)(50/pack) 2 packs
    Ceramic Homogenizer(100/pack) 1 pack
    Certificate of Conformity, Warranty Card,  English User Manual 1 copy
    Optional
    Module
    Built-in Filtration (HRH-40PRO, HRH-60PRO, HRH-Q120) 1 set
    Nitrogen Blow-down and Reconstitution (Dim: 930×910×2100mm) (HRH-40PRO, HRH-60PRO, HRH-Q120) 1 set
    SPE for Veterinary Drug (HRH-40PRO, HRH-60PRO, HRH-Q120)  1 set
    Integrated Salt Bin (HRH-Q120 only) 1 set
    Refrigerated Storage for Finished Samples (HRH-40PRO, HRH-60PRO) 1 set
    ISTD (HRH-40PRO, HRH-60PRO, HRH-Q120) 1 set
    Multi-protocol (HRH-40PRO, HRH-60PRO, HRH-Q120) 1 set

    Compliance

    1. GB 23200.113—2026 National Food Safety Standard Determination of 242 Pesticides and Metabolites Residues in Foods of Plant Origin - Gas Chromatography-tandem Mass Spectrometry Method.

    2. GB 23200.121—2026 National food safety standard—Determination of 352 pesticides and metabolites residues in foods of plant origin—Liquid chromatography-tandem mass spectrometry method.

    3. Pharmacopoeia of the People's Republic of China 2025 Edition (Volume IV), 2341 – Method 4 for the Determination of Pesticide Multiresidues: Determination of Pesticide Multiresidues (Mass Spectrometry); Method 5: Determination of Prohibited Pesticide Multiresidues in Medicinal Materials and Decoction Pieces (Botanical).

    4. AOAC 2007.01 Determination of pesticide residues in food using acetonitrile extraction and magnesium sulfate separation.

    5. EN 15662:2018 Foods of plant origin - Multimethod for the determination of pesticide residues using GC- and LC-based analysis following acetonitrile extraction/partitioning and clean-up by dispersive SPE - Modular QuEChERS-method.

    Typical Users

    Shaanxi Kangrun Xinze Medical Co., Ltd.
    Shandong Jiamao Biological Technology Co.,Ltd.
    Wuhan Kedao Industry and Trade Co., Ltd
    Suzhou Food Inspection and Testing Center
    Shenzhen Academy of Metrology & Quality Inspection (SMQ)
    Hebei Mingmei Instrument Equipment Technology Co.,Ltd.
    Centre Testing International (Qingdao)Co.,Ltd.
    Hubei Provincial Institute For Food Supervision And Test
    Fujian Inspection and Research Institute for Product Quality (FQII)
    Yangshengtang Co., Ltd.
    Merieux NutriSciences Testing Technology (Qingdao) Co., Ltd.
    Shanghai Agricultural Technology Extension and Service Center
    Shaanxi Keyi Sunshine Testing Technology Service Co., Ltd.
    Taian Customs
    Weifang Customs
    Ningbo Customs
    Ningde Product Quality Inspection Institute
    Xiamen Institute for Food and Drug Quality Control
    Guangzhou Inspection and Testing Certification Group Co., Ltd.
    Jiangsu Institute for Food and Drug Control
    Hubei Provincial Institute For Food Supervision And Test
    Hubei Institute of Product Quality Supervision and Inspection
    Shijiazhuang Grain and Oil Quality Monitoring Center
    Three Gorges Public Inspection and Testing Center
    Xi'an Supervision & Inspection Institute of Product Quality
    Jinan Agricultural Products Quality And Safety Center
    Hangzhou Institute of Food and Drug Inspection and Research
    Zhoushan Institute for Food and Drug Control
    Suqian Agricultural and Livestock Products Quality Testing Center
    Agriculture and Animal Husbandry Bureau of Alxa League
    Hangjinqi Agriculture and Animal Husbandry Bureau
    Shanghai Ocean University
    eurofins Sac Ky Hai Dang Co., Ltd
    eurofins Technology Service (Qingdao) Co., Ltd.
    eurofins Technology Service (Suzhou) Co., Ltd.
    Centre Testing International(Qingdao) Co.,Ltd.
    SGS-CSTC Standards Technical Services (Qingdao) Co., Ltd.
    Shaanxi Keyi Sunshine Testing Technology Service Co., Ltd.
    China Testing Certification Group (Shandong) Co., Ltd.
    CTC.(Anhui)Topway Testing Service Co.Ltd
    Inner Mongolia Yili Industrial Group Co.,Ltd.
    Yangshengtang Co., Ltd.
    Internal Trade Food Test & Scientific Research Institute
    Shan Dong Dong-E-E-Jiao Co., Ltd
    Xi'an United Nations Quality Detection Technology Co.,LTD
    Technology Center of Haikou Customs District
    Angel Yeast Co.,Ltd.
    Anhui Zhongqing Inspection and Testing Co.,Ltd
    Exhibition (2)
    Exhibition (1)
    Exhibition (2)
    Exhibition (1)
    Exhibition (2)
    Exhibition (1)
    Exhibition (1)
    Exhibition (1)
    Exhibition (1)
    Exhibition (1)

    Make An AppointmentLEAVE YOUR MESSAGE