High-Flow Bioaerosol Sampler HRH-DSA350 from China Suppliers & Factory for Efficient Airborne Particle Collection
Features
- Sampling Flow: 100-300L/min adjustable.
-
Sampling Efficiency:
• ≥70% when particle size ≤ 0.5μm.
• ≥75% when particle size is 0.5-1μm.
• ≥95% when particle size ≥ 2μm. - Sample Form & Volume: Forms liquid sample onsite by eluent within 1 min, which can be used for subsequent analysis.
- Working Conditions: -40℃ ~ 70℃.
- Power Duration: Unintermittent operation 24h after fully charged.
- Control: Supports wireless control and networking control.
- Sampling Mode: Four modes available (manual, auto, hardware triggered, software triggered).
- Weight: Sampler <3kg (with batteries).
- EMC: GJB151B-2013 compliant.
- Software Control: Can set sampling rate, sampling volume, sampling period and interval, sampling start delay, number of sampling cycles, device number, and network search.
- Real-time Display: Running time, number of completed cycles, sampled flow, remaining time, etc.
- Three-proof Packaging: Standard configurated three-proof packaging is easy for transportation.
Application Areas
Working Conditions
Temperature: -40℃ ~ 70℃
Conditions: All-weather (optional rain cover)
Storage Environment
Temperature: -40℃ ~ 70℃
Humidity: 5% ~ 98% RH (non-condensing state)
Sampler Technical Parameters
| Parameter Item | Technical Specification |
|---|---|
| Sampling range | Suitable for collecting biological aerosols, particulate matter, submicron particles, such as bacteria, viruses, fungi, molds, pollen and phage, etc. The standard bioaerosol cartridge is used for collecting bioaerosols and particulate aerosols. |
| Membrane type | Standard configurated biological aerosol cartridges. |
| Sampling mode | Four modes are available, including manual, auto, hardware triggered, software triggered. |
| Sampling principle | Filter trapping |
| Sampling flow | 100-300L/min adjustable |
| Sampling efficiency |
• Sampling efficiency ≥ 70% when particle size ≤ 0.5μm. • Sampling efficiency ≥ 75% when particle size is 0.5-1μm. • Sampling efficiency ≥ 95% when particle size ≥ 2μm. |
| Sample form and volume | Form liquid sample onsite by eluent within 1 min, which can be used for subsequent analysis. |
| Working temp | -40℃ ~ 70℃ (work uninterruptedly for 2hrs under extreme temp) |
| Storage temp | -40℃ ~ 70℃ |
| Relative humidity | 98% (35 ℃) |
| Working conditions | All-weather conditions (special protection kit for rain and snow) |
| Power supply | Built-in rechargeable battery, 110V/220V/50-60Hz AC or external 12V or 24V DC. Power rate <10W. |
| Power duration | Unintermittent operation ≥ 30h after fully charged (sampling efficiency ≥ 300L/min). |
| Sampling pump service life | 60,000 hours. |
| Noise | ≤ 60dB |
| Weight | Sampler <3kg (with batteries) |
| Casing | The main body of the casing is made of aluminum alloy, which is anti-electromagnetic and waterproof. |
| Control mode | Wired and wireless control |
| Interface | Standard DB-9 port |
| Software | Each sampler is equipped with software. The software can set: a. sampling rate, b. sampling volume, c. sampling period and interval, d. sampling starts delay, e. number of sampling cycles, f. device number, g. network search. Real-time display: running time, number of completed cycles, sampled flow, remaining time, etc. |
| Bioaerosol alarm trigger | Can be set and worked together with bioaerosol alarms. When bioaerosol alarms, the high-flow bioaerosol sampler will be activated, and the sampler will start working. |
| Sampler networking | Samplers can be connected to a network; multiple samplers in the network can be monitored and controlled at any time. |
| Cleaning and Sterilization | Fan housing and bioaerosol filter can be sterilized after wholly disassembling, and the sampler can be partially immersed in disinfectant or wiped on the surface. |
Eluent Technical Parameters
| Item | Technical Parameters |
|---|---|
| Principle | High-frequency vibration and mechanical pressure of membrane in liquid. |
| Elution time | ≤ 1 min |
| Power supply | 4x AA batteries or 220VAC 50Hz. |
| Weight | 1kg |
Frequently Asked Questions (FAQ)
The sampling flow rate is fully adjustable between 100 to 300 L/min to suit different environmental requirements.
The sampler achieves a sampling efficiency of ≥70% for particles ≤0.5μm, ≥75% for particles between 0.5-1μm, and ≥95% for larger particles ≥2μm.
It features four sampling modes: manual, automatic, hardware-triggered, and software-triggered. It also supports both wired and wireless networking control.
The built-in rechargeable battery supports unintermittent operation for ≥30 hours after being fully charged, even at a high sampling efficiency rate of ≥300L/min.
Yes, it is designed for all-weather conditions with a working temperature range of -40℃ to 70℃. An optional rain cover and special protection kit for rain and snow are available.
Using high-frequency vibration and mechanical pressure of the membrane in liquid, the eluent processes and forms a liquid sample onsite within 1 minute, which is immediately ready for subsequent analysis.