Features
- Sample collection form is liquid with highly flexible sample post-processing.
- High-speed airflow rate up to 300L/min, effective collection of low particle size particles, e.g., viruses and bacteria.
- With sampling flow rate adjustment function, sampling flow rate error can be controlled at ±5%.
- Easy programs setting, air flow rate, collection time, and delayed start can be set.
- Real-time solvents refilling realizes the long-term sampling.
- Two sampling modes: time sampling and volume sample.
- Main parts are detachable for autoclaving.
- Exquisite design, compact appearance, portable and humanized HMI.
- Compatibility: non-culture method PCR, IA, cell counting, ATP-bioluminescence assay, etc.
Application
Public places such as bus stations, railway stations, subways, airports, schools, etc. Public health areas such as indoor gas quality in clean rooms, hospitals, clean workshops, etc. Food processing fields, livestock farms, breeding fields, farmers' markets, etc. Customs and frontier fields.
1. Public health and health evaluation.
2. Evaluation of medical locations and facilities.
3. Workplace, architectural and indoor evaluation.
4. Evaluation of bioaerosols produced in industrial sites.
5. Assessment of gaseous biodiversity.
6. Evaluation of bioaerosol contamination in livestock facilities and farms.
7. Environmental assessment of food processing and cosmetic industry.
8. Evaluation of gnotobasis for drug production.
Working environment
Temperature: 0℃~50℃
Humidity: 5% -95% (non-condensing state)
Storage environment
Temperature: -20℃~60℃
Humidity: 5% -95% (non-condensing state)
Specification
| Dimensions | 176 × 250× 356mm |
| Weight | 5.3kg |
| Airflow | 300 L/min |
| Sampling time | 1~100 min, sampling delay time can be set |
| Solvents volume | ≤ 15mL |
| Sampling efficiency | >70% |
| Battery support time | Continuous running for 3 hours |
Standards
GB∕T 39990-2021 Particulate-Bioaerosol sampler-Technical specification
Frequently Asked Questions
What is the airflow rate of this bioaerosol sampler?
The sampler features a high-speed airflow rate of up to 300 L/min, which allows for the effective collection of low particle size particles such as viruses and bacteria.
What is the sampling efficiency of the device?
The device maintains a high sampling efficiency of greater than 70% (>70%) under standard operating specifications.
How long can the battery support continuous operation?
The built-in battery supports continuous running for up to 3 hours, making it highly portable for field operations.
Can the sampler components be autoclaved?
Yes, the main parts of the sampler are detachable, allowing them to be autoclaved for sterilization and preventing cross-contamination.
What are the compatible downstream analysis methods?
It is compatible with various analysis methods, including non-culture PCR, IA (Immunoassay), cell counting, and ATP-bioluminescence assays.
What standard does this bioaerosol sampler comply with?
This equipment complies with the GB∕T 39990-2021 Particulate-Bioaerosol sampler-Technical specification standard.