HRH-VOC186 VOC Generator: China Suppliers & Factory for Accurate Volatile Organic Compounds Evaporation
Features
Gas concentration generated is controllable and with high continuous stability.
Adopt glass ball stack convective volatilization structure with fast volatilization speed.
Assist heating volatile gas, temp can be controlled.
Generating system is closed with high safety.
Volatilization rate: 0-5mL/min, gas flow rate: 0-20L/min, heating temp: 20-60℃.
Application
Inhalation Toxicity Tests on VOC.
Health Risk Assessment of Environmental Atmosphere and Indoor Volatile Solvents.
Inhalation Toxicity Studies of VOC or Petrochemicals in Occupational Sites.
Online Monitor and Control for VOC.
Specification
| Parameter | Range / Value |
|---|---|
| Volatilization rate | 0-5mL/min |
| Gas flow rate | 0-20L/min |
| Heating temperature | 20-60℃ |
Working Principle
1. VOC concentration = liquid sample mass / (liquid sample gasification expansion volume + air volume); When the experimental concentration of VOC is designed to be relatively low, the concentration of VOC is ≈ liquid sample mass / air volume.
2. The temperature value set by the air heater is the temperature of the air outlet of the VOC system other than the hot air temperature after heating.
3. To be able to quantify the VOC content, the injection rate of the sample cannot exceed the maximum volatilization rate, ensuring that the sample injected into the volatilization tube is completely volatilized and no liquid flows into the cushion chamber.
4. Temperature control mode: The system automatically stops the air heating when the air outlet temperature exceeds the set upper limit, and automatically enables the air heating when the temperature drops below the set lower limit.
Frequently Asked Questions
What is the volatilization rate and gas flow rate of the system?
The system supports a volatilization rate of 0-5mL/min and a gas flow rate range of 0-20L/min.
What applications is this VOC generation system suitable for?
It is ideal for Inhalation Toxicity Tests, Health Risk Assessments of environmental and indoor volatile solvents, Inhalation Toxicity Studies in occupational sites, and Online Monitor and Control for VOC.
How does the system control the heating temperature?
The system features a temperature probe at the outlet to detect gas temperature and feed it back to the air heater. It automatically stops heating when the temperature exceeds the user-set upper limit and enables heating when it falls below the lower limit, controlling temperatures within 20-60℃.
Why is a glass ball stack structure used in the volatilization pipeline?
The glass ball stack convective structure increases the superficial area of the dropped liquid sample, which allows for significantly faster and more efficient volatilization.
How do you ensure proper quantification of the VOC content?
To accurately quantify the VOC content, the sample injection rate must not exceed the maximum volatilization rate, ensuring the liquid is fully volatilized before entering the cushion chamber.