The actual delivered dose, aerodynamic particle size distribution and lung deposition of inhalers depend on three correlating factors: patients, prescriptions and inhaler devices. Due to the characteristics of inhalers' forms, the current in vitro test methods regulated by Pharmacopoeia as well as the individual different situations, the correlation between in vitro and in vivo is weak and IVIVC studies become necessary.

IVIVC conducts in vitro tests by simulating human breath.  

There are individual differences between different patients, and the actual breathing profiles and inspiratory flow of the patients during inhalation are not consistent with the set flow in the in vitro test, which affects the drug distribution in the lungs and leads to inconsistent results in the in vitro test. This instrument can simulate human breath in the in vitro test, which makes the results more consistent with the actual situation and can be analyzed. IVIVC studies enhance the consistency evaluation of inhalers and bioequivalence.

    Features

    1.Precise control, high precision and stability.

    2.English/Chinese switchable interface is convenient for operation.

    3.Customized curve, which could simulate human breath of different age groups to meet different experimental needs.

    4.Smart control, customized parameters, eye-catching display.

    5.Used together with cascade impactor, it will make the in vitro correlation experiment of inhalers more consistent with the actual situation.

    Accessories

    In Vitro-In Vivo Correlation Test System (IVIVC) (1)

    Mixing Inlet

    In Vitro-In Vivo Correlation Test System (IVIVC) (2)

    Alberta Idealised Throat (Adult)

    Used to maintain the flow in cascade impactor, the inhaler flow should fit for patients' flow fluctuation. Meanwhile, it keeps the inhaler flow (pediatric studies) lower than min. flow of the multi-stage cascade impactor.

    The mixing inlet connects the induction port (or Alberta idealised throat) with the multi-stage cascade impactor, and separates the flow through inhaler from the multi-stage cascade impactor.
    Alberta idealised throat is one of the key factors in improving the clinical relevance of DDU testings and APSD testings.  

    Alberta idealised throat more closely represents the in vivo physiology of the real human body, and could provide more representative data.

    Specification

    Compressed air flow rate 0~100L/min
    Simulate peak inspiratory and expiratory flow 0~100L/min
    Increased flow rate 0-15L/s2
    Customized breath curve

    Compliance

    Good Cascade Impactor Practices, AIM and EDA for Orally Inhaled Products (2013)