Laskin Nozzle Aerosol Generator HRH-OAG4 - Top China Suppliers & Factory for Clean Room Leak Detection

The HRH-OAG4 Laskin Nozzle Aerosol Generator is a high-performance device designed to produce PAO aerosol using advanced Laskin nozzles. This innovative product features a built-in regulating valve that allows for flexible adjustment to either 6 or 10 nozzles. With an impressive output aerosol concentration ranging from 10 µg/L to 100 µg/L and an adjustable airflow rate between 1.4 m³/min and 56.6 m³/min, this aerosol generator meets stringent National Standards. It is an essential tool for leakage detection in clean rooms and high-efficiency filters in medical equipment inspection institutes, CDCs, hospitals, and pharmaceutical enterprises. As a leading factory in China, we are committed to providing top-quality products to our customers. Partner with us, recognized suppliers in the industry, for reliable and efficient aerosol generation solutions.

    Key Features

    Unique air path design engineered for stable airflow and balanced particle output.

    Generates multiple aerosol substances, including PAO, DOP, DOS, and related media.

    Adjustable spray concentration featuring a wide, versatile regulation range.

    Aerosol particle size distribution fully complies with National Standards.

    Technical Specifications

    Dimensions 355 x 265 x 252 mm
    Weight 10 kg (host), 0.5 kg (probe)
    Power Supply 220VAC, 50/60Hz
    Display Range 0.0001% ~ 100.0%
    Dynamic Range 0.0001 ~ 600 µg/L
    Alarm System Built-in sound and light alarms on both the control panel and scanning probe when concentration exceeds the threshold. Sound alarm can be muted anytime.
    Settable Aerosols PAO, DOP, etc.
    Accuracy 1% of reading value (0.01% ~ 100%)
    Repeatability 0.5% of reading value (0.01% ~ 100%)
    Light Source Long-life solid LED
    Flow Control 28.3 L/min ± 5%
    Auto Zero Establishes zero point automatically at startup
    Report Mode Continuous mode, Storage mode, Print mode

    Standards & Compliance

    GB 50591-2010 Code for Construction and Acceptance of Cleanroom
    GB 50073-2013 Code for Design of Clean Room
    YY 0569-2011 Class II Biological Safety Cabinets
    JJF 1800-2020 Calibration Specification of Aerosol Photometers
    JJF 1815-2020 Calibration Specification for Class II Biosafety Cabinets
    ISO 14644-3:2005 Cleanrooms and associated controlled environments - Part 3: Test methods
    Good Manufacturing Practice for Drugs (2010 Revision) - Premises and Facilities

    Frequently Asked Questions (FAQ)

    Which aerosol types are compatible with this equipment?

    The instrument supports multiple aerosol types including PAO, DOP, DOS, and other standardized testing aerosols.

    What is the measurement range and accuracy of the photometer?

    It offers a display range of 0.0001% to 100.0% and a dynamic range of 0.0001 to 600 µg/L, with an accuracy of 1% and repeatability of 0.5% of reading value (0.01%~100%).

    How does the alarm system operate during concentration overflow?

    The system provides dual sound and light alarms on both the main control panel and the scanning probe whenever the detected concentration exceeds the set threshold. The audible alarm can be deactivated at any time.

    Does the instrument perform automatic zero calibration?

    Yes, the device automatically establishes its zero reference point upon system startup.

    What reporting and data export modes are supported?

    The device supports three operating reporting modes: continuous mode, storage mode, and direct print mode.

    What international and cleanroom standards does this device meet?

    The equipment complies with ISO 14644-3:2005, JJF 1800-2020, JJF 1815-2020, YY 0569-2011, GB 50591-2010, GB 50073-2013, and GMP for Drugs (2010 Revision).