Liquid Aerosol Generator from China Suppliers and Factory - High-Quality, Corrosion-Resistant, and Efficient Atomization
Features
1
Aerosol particle size distribution is MMAD1-3μm, GSD1.5-3 which meets OECD TG 403 Acute Inhalation Toxicity (2009) and other standards.
2
Atomized by compressed air without heat generation, liquid samples can be generated into even and stable aerosol.
3
Applicable to various water-soluble and oil-soluble liquid samples and suspensions with some stable fine particles.
4
Applicable to aerosol generating from rare samples in large dose.
5
Applicable to microbial aerosol generation with minimal damage to microorganisms, and can be applied in animal inhalation infection models and related research.
6
Made of medical-grade SS316L, PTFE and high borosilicate glass, which are anti-corrosion and can be autoclaved.
Application
Inhalation Toxicology Research
Aerobiology
Aerosol Research
Biohazard Testing
Filter Performance Evaluation
Inhalation Immunity
Inhalation Therapy
Drug Research
Environmental Evaluation
Biological and Chemical Hazard Assessment
Medical Protection
Specification
| Connection Specification | Details |
|---|---|
| Specification of silicon tube in connection with refilling port | 2mm x 4mm |
| Outer diameter of PU tubes in connection with air compressor | 6.5mm x 10mm |
| Aerosol outlet specification | 16mm x 20mm |
| Generated aerosol | MMAD: 1-3μm, GSD: 1.5-3 |
| Product Name | Model | Rated Flow |
|---|---|---|
| Liquid Aerosol Generator | HRH-WAG1 | 2L/min |
| HRH-WAG3 | 6L/min | |
| HRH-WAG6 | 12L/min | |
| HRH-WAG1M | 2L/min | |
| HRH-WAG3M | 6L/min | |
| HRH-WAG6M | 12L/min | |
| HRH-WAG12 | 24L/min | |
| HRH-WAG24 | 48L/min |
Standards
OECD TG 403 Acute Inhalation Toxicity (2009)
OECD TG 436 Acute Inhalation Toxicity. Acute Toxic Class Method (2009)
OECD TG 412 28d Sub-acute inhalation (2018)
OECD TG 413 90d Sub-chronic inhalation (2018)
Frequently Asked Questions
What is the particle size distribution of the generated aerosol?
The generated aerosol particle size distribution has a Mass Median Aerodynamic Diameter (MMAD) of 1-3μm and a Geometric Standard Deviation (GSD) of 1.5-3. This meets the OECD TG 403 Acute Inhalation Toxicity (2009) and other related standards.
What materials is the Liquid Aerosol Generator made of?
The generator is constructed from high-quality, medical-grade SS316L stainless steel, PTFE, and high borosilicate glass. These materials provide excellent anti-corrosion properties and are fully autoclavable.
Can this generator handle microbial aerosol generation?
Yes, the system is designed to generate microbial aerosols with minimal damage to microorganisms. This makes it highly suitable for animal inhalation infection models and related biological research.
Does the aerosol generation process generate heat?
No, the system atomizes liquid samples using compressed air without generating heat. This ensures that temperature-sensitive liquid samples remain stable and uniform during aerosolization.
What types of liquid samples are compatible with this equipment?
It is highly versatile and applicable to various water-soluble and oil-soluble liquid samples, suspensions containing stable fine particles, and rare samples that require large-dose aerosol generation.
Which OECD testing guidelines does this device comply with?
The generator complies with multiple international standards, including OECD TG 403 (Acute Inhalation Toxicity), OECD TG 436 (Acute Toxic Class Method), OECD TG 412 (28d Sub-acute inhalation), and OECD TG 413 (90d Sub-chronic inhalation).