Request a Quote
Leave Your Message

Multi-concentration Nose-only Inhalation Exposure System for Rodents - Reliable China Suppliers and Factory Solutions

The Multi-concentration Nose-only Inhalation Exposure System for Rodents is an innovative solution designed for conducting precise nose-only inhalation toxicity tests. This advanced system is ideal for evaluating multiple concentration bioaerosols, chemical aerosols, smoke, and more. With a focus on ensuring dose consistency within the same test group, it features online monitoring of aerosol concentrations and real-time sampling capabilities

    Features

    Feature 01

    The nose only exposure chamber is constructed as a double core stainless steel structure, with positive pressure in the inner core and negative pressure in the outer core, ensuring that the exhaust gas exhaled by the animals does not contaminate or dilute the aerosol.

    Feature 02

    In a single experiment, either single concentration or multi concentration mode can be selected to perform aerosol inhalation exposure studies.

    Feature 03

    During the experiment, the uniformity and stability error of the aerosol mass concentration at each exposure port is within ±8% for gaseous test substances, within ±10% for liquid aerosols, and within ±20% for dust aerosols. These values comply with the OECD inhalation guidance documents and the national technical standards for toxicity testing of pesticides and chemicals.

    Feature 04

    The negative containment system ensures the safety of laboratory personnel.

    Feature 05

    The exhaust gas generated during the experiment is treated by a filtration system and fully meets national safety emission standards.

    Feature 06

    The software features user level management, audit trail, data unerasable and undeletable, electronic signatures, etc., meeting GLP requirements.

    Feature 07

    With the optional online pulmonary function monitoring system, the inhalation exposure experiment can be automatically terminated based on the theoretical inhaled dose.

    Application

    Drug Safety Evaluation

    Respiratory Disease Modeling and Drug Efficacy Evaluation

    Chemicals and Pesticide Safety Evaluation

    Hazard Assessment and Radioactive Substances Protection

    Inhalation Immunity and Environment Assessment

    Aerospace Medicine

    Standards

    OECD Guidelines

    • OECD TG 403 Acute Inhalation Toxicity (2009).
    • OECD TG 436 Acute Inhalation Toxicity. Acute Toxic Class Method (2009).
    • OECD TG 412 28d Sub-acute inhalation (2018).
    • OECD TG 413 90d Sub-chronic inhalation (2018).

    Pesticide Registration Standards

    • GB /T 15670.6 ~2017 Toxicological test methods for pesticides registration—Part 6: Acute inhalation toxicity test.
    • GB /T 15670.12 ~ 2017 Toxicological test methods for pesticides registration—Part 12: Short-term repeated dose 28-day inhalation toxicity study.
    • GB /T 15670.13 ~2017 Toxicological test methods for pesticides registration—Part 13: Subchronic toxicity study.
    • GB /T 15670.26 ~ 2017 Toxicological test methods for pesticides registration—Part 26: Chronic toxicity study.

    MEE New Chemical Substances

    • 403 Acute Inhalation Toxicity(2013, 2nd edition).
    • 436 Acute Inhalation Toxicity Test:Acute Toxic Class Method(2013, 2nd edition).
    • 412 Sub-acute inhalation:28-days test(2013, 2nd edition).
    • 413 Sub-chronic inhalation:90-days test(2013, 2nd edition).

    Typical Users

    Chinese Academy of Inspection and Quarantine
    China Institute for Radiation Protection
    Naval Medical University
    Kunming Institute of Zoology. CAS
    Zhengzhou National Tobacco Quality Supervision and Inspection Center

    Frequently Asked Questions

    How does the nose-only exposure chamber prevent aerosol contamination?
    The chamber features a double core stainless steel structure. Positive pressure in the inner core and negative pressure in the outer core ensure that exhaled exhaust gas from the animals does not contaminate or dilute the test aerosol.
    What are the aerosol concentration stability error margins?
    During experiments, the uniformity and stability error is within ±8% for gaseous substances, within ±10% for liquid aerosols, and within ±20% for dust aerosols, which complies with OECD and national standards.
    Does the software meet GLP compliance requirements?
    Yes, the system software supports user level management, audit trails, unerasable and undeletable data storage, and electronic signatures, fully meeting GLP requirements.
    What are the primary applications of this system?
    It is widely used in Drug Safety Evaluation, Respiratory Disease Modeling, Chemical and Pesticide Safety Evaluation, Hazard Assessment, Inhalation Immunity, and Aerospace Medicine.
    Can the inhalation exposure experiment be terminated automatically?
    Yes, by integrating the optional online pulmonary function monitoring system, the exposure experiment can be automatically terminated based on the calculated theoretical inhaled dose.

    Make An AppointmentLEAVE YOUR MESSAGE