Nasal Spray Fine Particle Dose Measurement: China Factory Suppliers for Accurate Drug Delivery Solutions

,

In order to achieve optimal drug deposition in the nasal cavity instead of the lungs, nasal products like nasal sprays are designed to produce particles with aerodynamic diameters primarily ranging from 20-200 µm. However, it is important to note that up to 5% of these particles may have aerodynamic diameters under 10 µm, which can lead to deposition in the lower respiratory tract and lungs. Therefore, quantifying the fine particle dose (FPD) generated by nasal sprays is crucial. Our solution utilizes cascade impactors to effectively capture particles in the 0-10 µm range. By combining the cascade impactor with a nasal spray expansion chamber, we accurately measure the fine particle dose of drugs in nasal sprays and nasal aerosols. As a leading factory and supplier in China, we are committed to providing advanced technology for the analysis of nasal aerosol products.

,

    Features

    Cascade impactors are used to capture 0-10μm particles. The combination of cascade impactor with nasal spray expansion chamber is used to measure fine particle dose of drugs in nasal sprays and nasal aerosols.

    Application

    Nasal Spray FPD Tests

    Specification

    • 1L capacity: Used in nasal aerosols to maximize deposition below the top stage.
    • 2L capacity: Used in nasal sprays to maximize nebulization and deposition.
    • 5L capacity: For some stronger nasal sprays, additional room is required to be able to generate aerosol plume.
    Notes: Not mandatory to use the expansion chamber for Nasal Powder FPD testing, as its test method is the same as the Dry Powder Inhalers by equipping the same test instrument and accessories, no pre-separator is required.

    Accessories

    part

    Inhaler Testing Data Analysis Software Instruction

    The main interface of the analysis software is shown in Figure 20. After inputting flow, the software will automatically calculate the cutting particle size. The information related to the experiment can be filled in on the right. The current experiment information can be saved by the Save button. Open the previously saved experiment information by the Open button and click the Next button to enter the data input interface after confirming the flow rate.

    In the data input interface, each column represents an experiment, and each row corresponds to a different stage of the device. The number of experiments can be selected on the right side of the data sheet, and open data files and save data as files by Open and Save Button. After data input is completed, click the Next button to enter the result display interface. The result display interface can display parameters (such as MMAD and GSD) of each experiment as well as particle size distribution fitting curve and scatter diagram. It's allowed to choose to display the curve of any experiment or the curve of all experiments. Click the right mouse button in terms of graphs to export the curve graph.

    Inhaler Testing Data Analysis Software Instruction
    Inhaler Testing Data Analysis Software Instruction1

    Compliance

    FDA Bioavailability and Bioequivalence Studies for Nasal Aerosols and Nasal Sprays for Local Action (2003)
    FDA Nasal Spray, Inhalation Solution, Suspension & Spray Drug Products (2002)
    Nasal Preparations (Dosage Forms 0676) Ph.Eur. 2021 10.5

    Typical Users

    United Arab Emirates University
    Genix Pharma Private Limited
    Drug International Limited
    Endocrine Technologies Llc
    Novel Phase
    Divine Healthcare Pvt. Ltd.
    Cipla Ltd.
    JOINN Laboratories
    Pharmaron Beijing Co., Ltd.
    Boji Medical Technology Co., Ltd.
    Tianjin Pharmaceutical Research Institute Co., Ltd.
    China State Institute of Pharmaceutical Industry (Haimen) R&D Co., Ltd.
    Shenyang SYRICI Testing Co., Ltd (SYRICIT)
    Guangdong Zhongke Yinghai Tech Co., Ltd.
    Jiangsu Medicine Research Institute
    Chinese Academy of Sciences Shanghai Institute of Materia Medica
    Shenyang Pharmaceutical University Wuya College of Innovation
    Jiangxi University of Chinese Medicine
    Kunming Institute of Zoology. Cas
    Zhongshan Research Institute, Shanghai Institute of Materia Medica
    ZhongShan Institute for Drug Discovery
    Shanghai Xiandai Medicine Preparation Engineering Research Centre Co.,Ltd.
    Northeastern University
    China Institute for Radiation Protection
    Hubei Provincial Center for Disease Control and Prevention
    Inner Mongolia Medical University
    Weifang Medical University
    Suzhou Jingzida Testing Service Co., Ltd.
    Suzhou Inhal Pharma Co., Ltd.
    Zhejiang Cdmo Pharmaceutical Co., Ltd
    Hangzhou Zhezhong Pharmaceutical Technology Co., Ltd.
    Jinan Kangqiao Medical Technology Co., Ltd.
    Anhui JieXi Pharmaceutical Co., Ltd.
    Beijing Xingyuanxiang Biotechnology (Group) Co., Ltd.
    Hunan Prima Pharmaceutical Research Center Co., Ltd.
    Beijing Wehand-bio Pharmaceutical Co.,ltd
    Jinan Baohede Pharmaceutical Technology Co., Ltd.
    Shandong Innovative Drug Research and Development Co., Ltd.
    Zhongshan Liansi Chemical Technology Co., Ltd.
    Jiangxi Zhonglu Science & Technology Co., Ltd.
    Shanghai Zezheng Biopharmaceutical Co., Ltd.
    Guangzhou Puzhiyun Information Technology Co., Ltd.
    Guangzhou Coslan Scientific Instrument Co., Ltd.
    Hainan Dayi Scientific Instrument Co., Ltd.

    Frequently Asked Questions

    Q1: What are cascade impactors used for in nasal drug delivery testing?
    Cascade impactors are utilized to capture particles in the 0-10μm range. When combined with a nasal spray expansion chamber, they measure the fine particle dose (FPD) of drugs in nasal sprays and nasal aerosols.
    Q2: How do I choose the correct expansion chamber capacity?
    The capacity depends on your testing requirements: 1L capacity is used for nasal aerosols to maximize deposition below the top stage; 2L capacity is ideal for nasal sprays to optimize nebulization and deposition; and 5L capacity is designed for stronger nasal sprays requiring extra space to generate the aerosol plume.
    Q3: Is an expansion chamber required for Nasal Powder FPD testing?
    No, it is not mandatory. Nasal Powder FPD testing follows the same method as Dry Powder Inhalers (DPIs), utilizing the same testing instrument and accessories without needing a pre-separator.
    Q4: What data parameters can the Inhaler Testing Data Analysis Software calculate and display?
    The software automatically calculates cutting particle size based on the flow rate. It displays key experimental parameters such as MMAD (Mass Median Aerodynamic Diameter) and GSD (Geometric Standard Deviation), along with particle size distribution fitting curves and scatter diagrams.
    Q5: Can I export graphs and save experiment configurations in the software?
    Yes. You can save current experiment configurations and open previously saved files using the Save and Open buttons. Additionally, you can export the curve graphs by right-clicking on them within the result display interface.
    Q6: What regulatory standards does this testing setup comply with?
    The testing processes align with FDA Bioavailability and Bioequivalence Studies for Nasal Aerosols and Nasal Sprays for Local Action (2003), FDA Nasal Spray, Inhalation Solution, Suspension & Spray Drug Products (2002), and Ph.Eur. 2021 10.5 Nasal Preparations.

    Make An AppointmentLEAVE YOUR MESSAGE