Nasal Spray Fine Particle Dose Measuring

To ensure better drug deposition in nasal cavity rather than lung, nasal products such as nasal sprays generate particles with aerodynamic diameters mostly among 20-200μm. However, there will be 5% (or less) particles with aerodynamic diameters under 10μm generated, and deposited in the lower respiratory tract and lung. It is therefore important to quantify fine particle dose (FPD) generated by nasal sprays. Cascade impactors are used to capture 0-10μm particles. The combination of cascade impactor with nasal spray expansion chamber is used to measure fine particle dose of drugs in nasal sprays and nasal aerosols. 

    Nasal Spray Fine Particle Dose Measuring (1)

    Features

    Cascade impactors are used to capture 0-10μm particles. The combination of cascade impactor with nasal spray expansion chamber is used to measure fine particle dose of drugs in nasal sprays and nasal aerosols.

    Application

    Nasal Spray APSD and FPD Tests

    When evaluating the in vitro aerodynamic characteristics of Orally Inhaled and Nasal Drug Products (OINDPs), the exceptionally high initial kinetic energy of nasal spray plumes represents the most significant fluid dynamic challenge. Directly actuating the nasal spray toward the impactor or induction port causes the high-velocity jet stream to generate substantial artifactual impaction losses, as a large fraction of drug droplets fail to follow the airflow streamlines. This not only contaminates the instrument but also leads to serious mass balance failures.

    This instrument completely resolves this issue by incorporating a precisely calibrated glass expansion chamber. The expansion chamber provides a critical physical buffer zone that allows aerosol droplets to decelerate naturally within an unconfined space, while simultaneously promoting the necessary evaporation of volatile components and stabilization of droplet morphology. Only after the complete dissipation of the high kinetic energy are the fine particles in the 0–10μm range—those truly posing a risk of deep lung deposition—smoothly drawn into the downstream cascade impactor for accurate aerodynamic size fractionation.

    Specification

    1L capacity: Optimized for nasal aerosols; utilizes a short settling path to maximize natural deposition of large droplets prior to the impactor top stage, thereby preventing overloading of the subsequent impactor collection plates.

    2L capacity: The industry-standard configuration, designed for conventional pump-action nasal sprays, providing optimal expansion space to allow full plume development and consistent deposition profiling.

    5L capacity: Custom-designed for high-dose or high-velocity nasal sprays, offering sufficient aerodynamic dissipation space to eliminate flow turbulence and wall-rebound effects that may otherwise compromise the spray pattern.

    Notes: it is not mandatory to use the expansion chamber for Nasal Powder FPD testing, as its test method is the same as the Dry Powder Inhalers by equipping the same test instrument and accessories, no pre-separator is required.

    Nasal Spray Fine Particle Dose Measuring (2)

    Accessories

    part

    Inhaler Testing Data Analysis Software Instruction

    The main interface of the analysis software is shown in Figure 20. After inputting flow, the software will automatically calculate the cutting particle size. The information related to the experiment can be filled in on the right. The current experiment information can be saved by the Save button. Open the previously saved experiment information by the Open button and click the Next button to enter the data input interface after confirming the flow rate. 
    In the data input interface, each column represents an experiment, and each row corresponds to a different stage of the device. The number of experiments can be selected on the right side of the data sheet, and open data files and save data as files by Open and Save Button. After data input is completed, click the Next button to enter the result display interface. The result display interface can display parameters (such as MMAD and GSD) of each experiment as well as particle size distribution fitting curve and scatter diagram. It's allowed to choose to display the curve of any experiment or the curve of all experiments. Click the right mouse button in terms of graphs to export the curve graph.Inhaler Testing Data Analysis Software InstructionInhaler Testing Data Analysis Software Instruction1

    Compliance

    光影魔术手拼图2

    FDA Bioavailability and Bioequivalence Studies for Nasal Aerosols and Nasal Sprays for Local Action (2003)
    FDA Nasal Spray, Inhalation Solution, Suspension & Spray Drug Products(2002)
    Nasal Preparations (Dosage Forms 0676) Ph.Eur. 2021 10.5


    Typical Users


    United Arab Emirates University
    Genix Pharma Private Limited
    Drug International Limited
    Endocrine Technologies LLC
    Novel Phase
    ESKAYEF PHARMACEUTICALS LIMITED
    Divine Healthcare Pvt. Ltd.
    Cipla Ltd.
    pure pharmaceutical manufacturing L.L.C
    JOINN Laboratories
    Pharmaron Beijing Co., Ltd.
    Boji Medical Technology Co., Ltd.
    Tianjin Pharmaceutical Research Institute Co., Ltd.
    China State Institute of Pharmaceutical Industry (Haimen) R&D Co., Ltd.
    Shenyang SYRICI Testing Co., Ltd (SYRICIT)
    Guangdong Zhongke Yinghai Tech Co., Ltd. 
    Jiangsu Medicine Research Institute
    Chinese Academy of Sciences Shanghai Institute of Materia Medica
    Shenyang Pharmaceutical University Wuya College of Innovation
    Jiangxi University of Chinese Medicine
    Kunming Institute of Zoology. Cas
    Zhongshan Research Institute, Shanghai Institute of Materia Medica
    ZhongShan Institute for Drug Discovery
    Shanghai Xiandai Medicine Preparation Engineering Research Centre Co.,Ltd. 
    Northeastern University
    China Institute for Radiation Protection 
    Hubei Provincial Center for Disease Control and Prevention
    Inner Mongolia Medical University
    Weifang Medical University
    Suzhou Jingzida Testing Service Co., Ltd. 
    Suzhou Inhal Pharma Co., Ltd. 
    Zhejiang Cdmo Pharmaceutical Co., Ltd
    Hangzhou Zhezhong Pharmaceutical Technology Co., Ltd.
    Jinan Kangqiao Medical Technology Co., Ltd.
    Anhui JieXi Pharmaceutical Co., Ltd.
    Beijing Xingyuanxiang Biotechnology (Group) Co., Ltd.
    Hunan Prima Pharmaceutical Research Center Co., Ltd.
    Beijing Wehand-bio Pharmaceutical Co.,ltd
    Jinan Baohede Pharmaceutical Technology Co., Ltd.
    Shandong Innovative Drug Research and Development Co., Ltd.
    Zhongshan Liansi Chemical Technology Co., Ltd.
    Jiangxi Zhonglu Science & Technology Co., Ltd.
    Shanghai Zezheng Biopharmaceutical Co., Ltd.
    Guangzhou Puzhiyun Information Technology Co., Ltd.
    Guangzhou Coslan Scientific Instrument Co., Ltd.
    Hainan Dayi Scientific Instrument Co., Ltd.

    Make An AppointmentLEAVE YOUR MESSAGE