Negative Pressure Necropsy Cabinet
Features
1.Whole body is made of SS304, delicate and corrosion-resistant plastic spraying treated on the outer surface.
2.Equipped with double-sided windows in ergonomic inclination design, easy for operation.
3.Average airflow rate in single working window0.5m/s.
4.Airflow mode: airflow at all positions of the working window is inward and without emission.
5.Adopt negative pressure exhaust design in working area, with max. volume of 1500m/h, which allows indoor exhaust.
6.Equipped with EBM fan with low energy consumption and stable performances.
7.Adopt Class H14 HEPA filters with efficiency99.99%.
8.Exhaust HEPA filter can perform leak detection and sterilization in place.
9.Two 220V/10A waterproof sockets on the side of working area, convenient to use.
10.Two UV lights on the side of working area for ultraviolet sterilization.
11.Concave design working table has 3 trays for easy cleaning.
12.Working table has a sink for easy washing and waste collection.
13.Pressurized bag or airtight bin can be attached to the bottom of sink for waste transfer.
14.With two faucets and handy water guns above the sink for easy cleaning working table.
15.Alarm system: glass door height alarms, filter pressure alarms, etc.
16.Power supply: AC220V/50Hz.
17.Dimensions: 1500*820*2220mm.
Typical Users
PLA Unit 32734
National Institutes for Food and Drug Control
Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences The First Affiliated Hospital of Nanchang University
Chemical Defense Institute, Academy of Military Sciences, PLA
WUHAN INSTITUTE OF BIOLOGICAL PRODUCTS CO.,LTD.
PLA Army Chemical Defense College
Military Veterinary Institute, Academy of Military Medical Sciences, Academy of Military Sciences, PLA
Guangzhou Customs Technology Center
The Fifth Medical Center of the PLA General Hospital
Application
Exposure tests of inhalation infection, inhalation immunity, inhaler R&D in ABSL-3 and ABSL-4 laboratories.
Specification
| Item | Technical Parameters |
| Dimensions | 1500*820*2220mm |
| Operation | Double-sided |
| HEPA filter | H14, can be sterilized and detected leakage in place |
| Alarm | Glassdoor height alarms, filter pressure alarms |
| Clean | Two faucets and handy water guns |
| Sink | 14L sink on worktable |
| Table arc | ≥R12 |
| UV light | 2*8W |
| Illumination | 4*10W lights |
| Airflow (m3/h) | 1500 |
| Power supply | AC220V/50Hz |
| Power rate(kW) | 0.8 |
Standards
RB∕T 199-2015 Technical code for evaluating biosafety performance of laboratory equipment