🚀 Features
- Nose-only exposure tower has stainless steel double cores with positive pressure in inner core and negative pressure in outer core to ensure waste gases exhaled by animals without contamination or aerosol dilution.
- The evenness and stability error of each exposure port's mass concentration during tests for gas is within ±8%, for liquid aerosol is within ±10%, while for dust aerosol is within ±20%, which conforms to technical requirements of OECD inhalation guidelines.
- Negative pressure protection system can guarantee the safety of personnel.
- Waste gas can fully meet Safety Emission Standards after treatment.
- Functions can fully meet requirements of GLP laboratories, for example, user classified management, audit trail, data unerasable and electronic signature, etc.
💡 Application
Toxicology and safety testing of pharmaceutical agents.
Respiratory Disease Modeling and Drug Efficacy Evaluation.
Chemicals and Pesticide Safety Evaluation.
Hazard Assessment and Radioactive Substances Protection.
Inhalation Immunity and Environment Assessment.
Specialized aerospace environmental medicine research.
⚙️ Components
1. Liquid Aerosol Generator
- a. Aerosol particle size distribution is MMAD1-3μm, GSD1.5-3 which meets OECD TG 403;
- b. Atomized by compressed air heatlessly, liquid samples can be generated into even and stable aerosol;
- c. Applicable to various water-soluble and oil-soluble liquid samples and suspensions with some stable fine particles;
- d. Applicable to aerosol generating from rare samples in large dose;
- e. Applicable to microbial aerosol generation with minimal damage on microorganisms, and can be applied to animal inhalation infection models and related research;
- f. Made of medical-grade SS316L, Teflon and high borosilicate glass, which are anti-corrosion and can be autoclaved.
| Model | Nozzle number | Rated gas flow |
|---|---|---|
| HRH-WAG1 | 1 | 2L/min |
| HRH-WAG3 | 3 | 6L/min |
| HRH-WAG6 | 6 | 12L/min |
| HRH-WAG1M | Micro liquid 1 nozzle | 2L/min |
| HRH-WAG3M | Micro liquid 3 nozzles | 6L/min |
| HRH-WAG6M | Micro liquid 6 nozzles | 12L/min |
| HRH-WAG12 | 12 | 24L/min |
| HRH-WAG24 | 24 | 48L/min |
2. Dust Aerosol Generator
- a. MMAD (Mass Median Aerodynamic Diameter): 1-4μm (ISO 12103-A2 Fine Test Dust), GSD1.5-3.
- b. Offer report copy of dust particles aerodynamic particle size distribution generated by dust aerosol generator, issued by Academy of Military Medical Sciences;
- c. Working method: gradual expansion by rotating divergent brush;
- d. Particles: non-sticky powder or dust;
- e. Computer control: independent control system with real-time display of parameters, including gas source pressure, gas flow, powder mass flow, theoretical concentration, remaining working time and feeding speed, etc.;
- f. Dust loading: 10ml, 40ml, 300ml optional;
- g. Particle size: 0.1~20μm;
- h. Mass flow: 10~20000mg /min adjustable;
- i. Aerosol flow: 5~100L /min adjustable;
- j. Brush rotating speed: 600~1000rpm adjustable;
- k. Delivery period: 10min~400h;
- l. Dust residual: absolute value measured by electronic ruler;
- m. Flow monitor: monitor and display automatically;
- n. Dust mass concentration: calculate and display automatically;
- o. Protection alarm: Six-fold intelligent detection and protection alarm.
3. Single-channel Intelligent Smoking Machine (Optional)
- a. Complied with ISO3308 smoking standard, the machine can load with two cigarettes simultaneously, switch manual /auto mode to realize continuous smoking of bulk cigarettes, and also can be connected to exposure system seamlessly for standard cigarettes poisoning;
- b. Enable deep smoking mode;
- c. Easy to disassemble and clean as the smoking barrel is placed outside the machine;
- d. Special software with settable functions of flow rate, smoking time, interval, frequency, number of suctions, flow compensation, etc.;
- e. Pressure drop: pressure difference between cigarette butts and suction source is less than 200Pa;
- f. Standard smoking duration: 2±0.1s;
- g. Smoking capacity: 15~60ml, Control accuracy: ±0.1ml;
- h. Standard volume: 35±0.1 ml, Deep smoking: 55±0.1 ml;
- i. Smoking frequency: 10~240s adjustable, standard frequency is 60s;
- j. Center distance of burner reactor :> 50mm.
4. Ten-channel Fully Automatic Turntable Smoking Machine (Optional)
- a. With automatic cigarette loading and lighting, the machine adopts international standard bell-shaped curve and settable normal smoking curve. Cigarettes can be pulled out, extinguished and replenished automatically after burning out. The burning length of cigarettes can be set. The machine can also be connected to exposure system seamlessly for standard cigarette poisoning;
- b. Complied with ISO3308 smoking standard;
- c. Enable deep smoking mode;
- d. Cigarette bin capacity: 200 (midway feeding supported);
- e. Special software with settable functions of flow rate, smoking time, interval, frequency, number of suctions, flow compensation, etc.;
- f. Pressure drop: pressure difference between cigarette butts and suction source is less than 200Pa;
- g. Standard smoking duration: 2±0.1s;
- h. Smoking capacity: 15~60ml, Control accuracy: ±0.1ml;
- i. Standard volume: 35±0.1 ml, Deep smoking: 55±0.1ml;
- j. Smoking frequency: 30~240s adjustable, standard frequency is 60s.
5. E-Cigarette Vape Generator
- a. Compliant with E-cigarette vape smoke test methods of domestic and international standards (e.g., GB 41700-2022 Electronic Cigarette, France XP D90-300-3), E-cigarette vape generator adopts precise mechanical movement and electronic control module, it can be used for E-cigarette life test, vape mouthpiece test, battery life test, smoke resistance test and other performance tests. It can also be used for E-cigarette gas trapping analysis and gas exposure tests. Standard smoke capacity 55.0 ± 0.5mL.
- b. Standard smoke frequency 30.0 ± 0.3s.
- c. User-defined smoke capacity 15-60ml.
- d. User-defined smoke frequency 10-240s.
- e. Standard vape curve (optional multiple curves).
- f. E-cigarette tilt angle 0-90° to ensure complete heating of tobacco oil.
- g. Strong adaptability, sealed adapter can be customized according to different holders in different shapes.
- h. Independent control of smoking in each channel, synchronized vaping, asynchronous vaping, and individually setting vaping parameters.
- i. Configurated with Cambridge membrane clip, which is compatible with smoke trapper and meets various test requirements.
- j. Integrated smoking resistance detection and real-time recording of e-cigarette smoking resistance (For 4-channel and 10-channel).
6. Nose-Only Exposure Tower for Rodents
Adopt combinable structure in stainless steel 316L, the exposure tower is corrosion-resistant, easy to clean, freely rotating and spared with detachable parts. It is used for completing rodent inhalation tests (for example: rats, mice, guinea pigs, ferrets and rabbits, etc.). The exposure tower has double cores inner and outer. The uniformity and stability error of 36 inhalation exposure ports' mass concentration for gas is within ±8%, for liquid aerosol is within ±10%, while for dust aerosol is within ±20%.
7. All-Glass Impinger
Collect high-concentration bioaerosol with a sampling flow rate of 7–12.5 L, using 20 mL of sampling liquid. After sampling, perform plate coating, cultivation, and analysis.
8. Aerosol Mass Concentration Detector
- a. Sensor: visible red laser module with near forward light scattering at wave length 635nm;
- b. Measurement range: up to 250g/m3;
- c. Range mode: fixed or auto-selected;
- d. Communication mode: RS485 modbus communication;
- e. Alarm: can trigger and reset alarm according to user-defined trigger threshold and time;
- f. Data record: storage capacity is larger than 50,000 data points;
- g. Measurement display: Real-time numerical display or graphical display;
- h. Realize real-time online sampling of pre-test liquid aerosol and automatic adjustment to target value for test dose concentration via host control.
9. Fume Hood
- a. Fume Hood runs under negative pressure with air volume of 100 ~ 500m³/h, which is safe, reliable and easy to operate. Material of inner wall and table surface adopt food-grade and liquid corrosion resistant stainless-steel plate;
- b. Equipped with lighting system;
- c. Special design, integrate exposure system with fume hood seamlessly to realize double negative pressure control to keep personnel and environment safe.
10. Host Software
- a. With functions of user classified management, audit trail, data unerasable and electronic signature, etc., the software meets requirements of GLP and can perform tests overall control, parameter setting, real-time monitoring and recording for environmental parameters during tests, real-time alarm and recording of abnormalities;
- b. Various test data storage and access, automatically issue reports post-test, etc.
📋 Standards
① OECD TG 403 Acute Inhalation Toxicity (2009).
② OECD TG 436 Acute Inhalation Toxicity. Acute Toxic Class Method (2009).
③ OECD TG 412 28d Sub-acute inhalation (2018).
④ OECD TG 413 90d Sub-chronic inhalation (2018).
① GB /T 15670.6 ~2017 Part 6: Acute inhalation toxicity test.
② GB /T 15670.12 ~ 2017 Part 12: Short-term repeated dose 28-day inhalation.
③ GB /T 15670.13 ~2017 Part 13: Subchronic toxicity study.
④ GB /T 15670.26 ~ 2017 Part 26: Chronic toxicity study.
① 403 Acute Inhalation Toxicity(2013, 2nd edition).
② 436 Acute Inhalation Toxicity Test: Acute Toxic Class Method(2013, 2nd edition).
③ 412 Sub-acute inhalation:28-days test(2013, 2nd edition).
④ 413 Sub-chronic inhalation:90-days test(2013, 2nd edition).