Nose-Only Exposure System for Rodents - High Precision Inhalation Testing | China Suppliers & Factory
Features
Nose-only exposure tower has stainless steel double cores with positive pressure in inner core and negative pressure in outer core to ensure waste gases exhaled by animals without contamination or aerosol dilution.
The evenness and stability error of each exposure port's mass concentration during tests for gas is within ±8%, for liquid aerosol is within ±10%, while for dust aerosol is within ±20%, which conforms to technical requirements of OECD inhalation guidelines.
Negative pressure protection system can guarantee the safety of personnel.
Waste gas can fully meet Safety Emission Standards after treatment.
Functions can fully meet requirements of GLP laboratories, for example, user classified management, audit trail, data unerasable and electronic signature, etc.
Application
Components
- Aerosol particle size distribution is MMAD1-3μm, GSD1.5-3 which meets OECD TG 403;
- Atomized by compressed air heatlessly, liquid samples can be generated into even and stable aerosol;
- Applicable to various water-soluble and oil-soluble liquid samples and suspensions with some stable fine particles;
- Applicable to aerosol generating from rare samples in large dose;
- Applicable to microbial aerosol generation with minimal damage on microorganisms, and can be applied to animal inhalation infection models and related research;
- Made of medical-grade SS316L, Teflon and high borosilicate glass, which are anti-corrosion and can be autoclaved.
| Model | Nozzle number | Rated gas flow |
|---|---|---|
| HRH-WAG1 | 1 | 2L/min |
| HRH-WAG3 | 3 | 6L/min |
| HRH-WAG6 | 6 | 12L/min |
| HRH-WAG1M | Micro liquid 1 nozzle | 2L/min |
| HRH-WAG3M | Micro liquid 3 nozzles | 6L/min |
| HRH-WAG6M | Micro liquid 6 nozzles | 12L/min |
| HRH-WAG12 | 12 | 24L/min |
| HRH-WAG24 | 24 | 48L/min |
- MMAD (Mass Median Aerodynamic Diameter): 1-4μm (ISO 12103-A2 Fine Test Dust), GSD1.5-3.
- Offer report copy of dust particles aerodynamic particle size distribution generated by dust aerosol generator, issued by Academy of Military Medical Sciences;
- Working method: gradual expansion by rotating divergent brush;
- Particles: non-sticky powder or dust;
- Computer control: independent control system with real-time display of parameters, including gas source pressure, gas flow, powder mass flow, theoretical concentration, remaining working time and feeding speed, etc.;
- Dust loading: 10ml, 40ml, 300ml optional;
- Particle size: 0.1~20μm;
- Mass flow: 10~20000mg /min adjustable;
- Aerosol flow: 5~100L /min adjustable;
- Brush rotating speed: 600~1000rpm adjustable;
- Delivery period: 10min~400h;
- Dust residual: absolute value measured by electronic ruler;
- Flow monitor: monitor and display automatically;
- Dust mass concentration: calculate and display automatically;
- Protection alarm: Six-fold intelligent detection and protection alarm.
- Complied with ISO3308 smoking standard, the machine can load with two cigarettes simultaneously, switch manual /auto mode to realize continuous smoking of bulk cigarettes, and also can be connected to exposure system seamlessly for standard cigarettes poisoning;
- Enable deep smoking mode;
- Easy to disassemble and clean as the smoking barrel is placed outside the machine;
- Special software with settable functions of flow rate, smoking time, interval, frequency, number of suctions, flow compensation, etc.;
- Pressure drop: pressure difference between cigarette butts and suction source is less than 200Pa;
- Standard smoking duration: 2±0.1s;
- Smoking capacity: 15~60ml, Control accuracy: ±0.1ml;
- Standard volume: 35±0.1 ml, Deep smoking: 55±0.1 ml;
- Smoking frequency: 10~240s adjustable, standard frequency is 60s;
- Center distance of burner reactor :> 50mm.
- With automatic cigarette loading and lighting, the machine adopts international standard bell-shaped curve and settable normal smoking curve. Cigarettes can be pulled out, extinguished and replenished automatically after burning out. The burning length of cigarettes can be set. The machine can also be connected to exposure system seamlessly for standard cigarette poisoning;
- Complied with ISO3308 smoking standard;
- Enable deep smoking mode;
- Cigarette bin capacity: 200 (midway feeding supported);
- Special software with settable functions of flow rate, smoking time, interval, frequency, number of suctions, flow compensation, etc.;
- Pressure drop: pressure difference between cigarette butts and suction source is less than 200Pa;
- Standard smoking duration: 2±0.1s;
- Smoking capacity: 15~60ml, Control accuracy: ±0.1ml;
- Standard volume: 35±0.1 ml, Deep smoking: 55±0.1ml;
- Smoking frequency: 30~240s adjustable, standard frequency is 60s.
- Compliant with E-cigarette vape smoke test methods of domestic and international standards (e.g., GB 41700-2022 Electronic Cigarette, France XP D90-300-3), E-cigarette vape generator adopts precise mechanical movement and electronic control module, it can be used for E-cigarette life test, vape mouthpiece test, battery life test, smoke resistance test and other performance tests. It can also be used for E-cigarette gas trapping analysis and gas exposure tests. Standard smoke capacity 55.0 ± 0.5mL.
- Standard smoke frequency 30.0 ± 0.3s.
- User-defined smoke capacity 15-60ml.
- User-defined smoke frequency 10-240s.
- Standard vape curve (optional multiple curves).
- E-cigarette tilt angle 0-90° to ensure complete heating of tobacco oil.
- Strong adaptability, sealed adapter can be customized according to different holders in different shapes.
- Independent control of smoking in each channel, synchronized vaping, asynchronous vaping, and individually setting vaping parameters.
- Configurated with Cambridge membrane clip, which is compatible with smoke trapper and meets various test requirements.
- Integrated smoking resistance detection and real-time recording of e-cigarette smoking resistance (For 4-channel and 10-channel).
Single Channel
Four Channel
Ten Channel
Adopt combinable structure in stainless steel 316L, the exposure tower is corrosion-resistant, easy to clean, freely rotating and spared with detachable parts. It is used for completing rodent inhalation tests (for example: rats, mice, guinea pigs, ferrets and rabbits, etc.). The exposure tower has double cores inner and outer. The uniformity and stability error of 36 inhalation exposure ports' mass concentration for gas is within ±8%, for liquid aerosol is within ±10%, while for dust aerosol is within ±20%.
collect high-concentration bioaerosol with a sampling flow rate of 7–12.5 L, using 20 mL of sampling liquid. After sampling, perform plate coating, cultivation, and analysis.
- Sensor: visible red laser module with near forward light scattering at wave length 635nm;
- Measurement range: up to 250g/m3;
- Range mode: fixed or auto-selected;
- Communication mode: RS485 modbus communication;
- Alarm: can trigger and reset alarm according to user-defined trigger threshold and time;
- Data record: storage capacity is larger than 50,000 data points;
- Measurement display: Real-time numerical display or graphical display;
- Realize real-time online sampling of pre-test liquid aerosol and automatic adjustment to target value for test dose concentration via host control.
- Fume Hood runs under negative pressure with air volume of 100 ~ 500m³/h, which is safe, reliable and easy to operate. Material of inner wall and table surface adopt food-grade and liquid corrosion resistant stainless-steel plate;
- Equipped with lighting system;
- Special design, integrate exposure system with fume hood seamlessly to realize double negative pressure control to keep personnel and environment safe.
- With functions of user classified management, audit trail, data unerasable and electronic signature, etc., the software meets requirements of GLP and can perform tests overall control, parameter setting, real-time monitoring and recording for environmental parameters during tests, real-time alarm and recording of abnormalities;
- Various test data storage and access, automatically issue reports post-test, etc.
Standards
OECD Guidelines
- OECD TG 403 Acute Inhalation Toxicity (2009).
- OECD TG 436 Acute Inhalation Toxicity. Acute Toxic Class Method (2009).
- OECD TG 412 28d Sub-acute inhalation (2018).
- OECD TG 413 90d Sub-chronic inhalation (2018).
Pesticide Registration Standards
- GB /T 15670.6 ~2017 Toxicological test methods for pesticides registration—Part 6: Acute inhalation toxicity test.
- GB /T 15670.12 ~ 2017 Toxicological test methods for pesticides registration—Part 12: Short-term repeated dose 28-day inhalation toxicity study.
- GB /T 15670.13 ~2017 Toxicological test methods for pesticides registration—Part 13: Subchronic toxicity study.
- GB /T 15670.26 ~ 2017 Toxicological test methods for pesticides registration—Part 26: Chronic toxicity study.
New Chemical Substances Registration
- 403 Acute Inhalation Toxicity(2013, 2nd edition).
- 436 Acute Inhalation Toxicity Test: Acute Toxic Class Method(2013, 2nd edition).
- 412 Sub-acute inhalation:28-days test(2013, 2nd edition).
- 413 Sub-chronic inhalation:90-days test(2013, 2nd edition).
Typical Users
- Individualnyi Predprinimatel Pikeneeva Zinaida Fedorovna
- Biogen-Analytica Ltd.
- Vietnam High Technology Analysis and Testing Company Limited
- VINACERT Certification and Inspection Jsc
- Belarus National Center for Hygiene, Epidemiology and Public Health
- National Institutes for Food and Drug Control
- Peking University
- Joinn Laboratories (China) Co., Ltd.
- Zhejiang University
- Suzhou Xishan Zhongke Drug R&D Co. Ltd.
- Huazhong University of Science and Technology
- Chengdu Huaxi Haiqi Pharmaceutical Technology Co., Ltd.
- China Pharmaceutical University
- Haimen Yinuosi Biotechnology Co., Ltd.
- Lanzhou University
- Suzhou Jingzida Testing Service Co., Ltd.
- Hebei Medical University
- Jiangsu Pesticide Research Institute Company Ltd.
- Guangxi University of Science and Technology
- Medicilon/MPI Preclinical Research (Shanghai) LLC
- Inner Mongolia Medical University
- Shanghai Research Institute of Chemical Industry Co., LTD.
- Shenyang Medical College
- Tianjin Pharmaceutical Research Institute New Drug Evaluation Co., Ltd.
- Kunming Medical University
- Shenyang Research Institute of Chemical Industry Co., Ltd.
- Soochow University
- Technology Center of Ningbo Entry Exit Inspection and Quarantine Bureau
- The second Hospital of Hebei Medical University
- Guizhou Acade Analysis
- Shenzhen Prevention and Treatment Center for Occupational Diseases
- China Institute for Radiation Protection
- Xinqiao Hospital of Army Medical University
- Institue of Materia Medica, Academy of Military Medical Sciences
- Beijing Increase Pharmaceutical Institute Co., Ltd.
- Institute of Environmental Medicine and Occupational Medicine, Academy of Military Medical Sciences
- Guangzhou Institute of Respiratory Diseases
- Beijing National Center for Drug Safety Evaluation and Research
- Chinese Center for Disease Control and Prevention
- Guangdong Zhongke Yinghai Tech Co., Ltd.
- Jiangsu Provincial Center for Disease Control and Prevention
- Guangzhou Boji Pharmaceutical Biotechnology Co.,Ltd.
- Hubei Provincial Center for Disease Control and Prevention
- Jiangsu Agrochem Laboratory Co.,Ltd.
- China Tobacco Yunnan Industrial Co.,Ltd.
- Chinese Academy of Inspection and Quarantine
- CNTC
- Institute of Chinese Materia Medica, China Academy of Chinese Medical Sciences
- Shandong Institute of Occupational Disease Prevention and Control
- Henan Province Medical Instrument Testing Institute
- Institute of Materia Medica, Shandong Academy of Medical Sciences
- Beijing Beijiu Environmental Technology Laboratory
- Shenzhen First Union Technology Co., Ltd.
- Asia Biochemical Co., Ltd.
- Zhejiang Institute for Food and Drug Control
- Shenzhen Yueke Technology Co., Ltd.
- Hangzhou Breath Smooth Biomedical Technology Co., Ltd.
- Shenyang SYRICI Test Co., Ltd.
- Hunan Hanfang Biotechnology Co., Ltd.
- Hunan Prevention and Treatment Institute for Occupational Diseases
- PLA Army Chemical Defense College
- Hefei Nuoming Drug Safety Research Co., Ltd.
- Liaoning Qianyi Testing Technology Development Co., Ltd.
- Tianjin Pharmaceutical Group Research Institute Co., Ltd.
- Hubei Institute of Drug Supervision and Inspection
- Unit 63919 of PLA Drug Safety Evaluation Center
- Shandong Academy of Medical Sciences
- Shanxi Provincial Center for Disease Control and Prevention
- Shenyang Chemical Testing Technology (Nantong) Co., Ltd.
- Shandong Medical Device Product Quality Inspection Center
Publications
- [1] Chen Chu, Haiya Zhang, Shijie Cui, et al. Ambient PM2.5 caused depressive-like responses through Nrf2/NLRP3 signaling pathway modulating inflammation[J]. Journal of Hazardous Materials, 2019, 369: 180–190. htps://doi.org/10.1016/j.jhazmat.2019.02.026.
- [2] Chen Chu, Lixiao Zhou, Heran Xie, et al. Pulmonary toxicities from a 90-day chronic inhalation study with carbon black nanoparticles in rats related to the systemical immune effects[J]. International Journal of Nanomedicine, 2019,14: 2995–3013.
- [3] Xiaobo Li, Chengcheng Zhang, Qian Bian, et al. Integrative Functional Transcriptomic Analyses Implicate Specific Molecular Pathways in pulmonary toxicity from Exposure to Aluminum Oxide Nanoparticles[J]. Nanotoxicology, 2016, 10(7):957-969. Doi: 10.3109/17435390.2016.1149632.
- [4] Tao Yu, Xueyan Zhang, Lei Zhong, et al. The use of a 0.20 mm particulate mater filter decreases cytotoxicity in lung epithelial cells following air-liquid interface exposure to motorcycle exhaust[J]. Environmental Pollution, 2017, 227: 287-295. htp://dx.doi.org/10.1016/j.envpol.2017.04.080
- [5] Jiaze Shu, Defu Li, Haiping Ouyang, et al. Comparison and evaluation of two different methods to establish the cigarete smoke exposure mouse model of COPD[J]. Scientific Reports, 2017, 7:15454. DOI:10.1038/s41598-017-15685-y.
- [6] Biao Yang, Yu Zhang, Bingyu Li, et al. Fine particulate matter alters the microecology of the murine respiratory tract[J]. Environmental Science and Pollution Research, 2019, htps://doi.org/10.1007/s11356-019-04372-2.
- [7] Biao Yang, Jie Guo, Chunling Xiao. Effect of PM2.5 environmental pollution on rat lung[J]. Environmental Science and Pollution Research, 2018, htps://doi.org/10.1007/s11356-018-3492-y.
- [8] Sen Zhang, Huan Chen, An Wang, et al. Genotoxicity evaluation of carbon monoxide and 1, 3-butadiene using a new joint technology — the in vitro γH2AX HCS assay combined with air-liquid interface system[J]. Mechanisms and Methods, 2019, DOI:10.1080/15376516.2018.1477897.
- [9] Zhengwei Huang, Ying Huang, Cheng Ma, et al. Endotracheal Aerosolization Device for Laboratory Investigation of Pulmonary Delivery of Nanoparticle Suspensions: In Vitro and in Vivo Validation[J]. Mol. Pharmaceutics, 2018, DOI:10.1021/ acs.molpharmaceut.8b00668.
- [10] Cui Li, Siyu Liu, Gan Luo, et al. Comparison of plasma pharmacokinetics of Tanreqing solution between intratracheal aerosolization and intravenous injection in rats[J]. Biomedical Chromatography. 2017;e4116.
- [11] Jie Ning, Peiyuan Li, Boyuan Zhang, et al. miRNAs deregulation in serum of mice is associated with lung cancer related pathway deregulation induced by PM2.5, Environmental Pollution 254 (2019) 112875.
Frequently Asked Questions
Q: What standards do the exposure systems conform to?
The systems conform to various international standards including OECD Guidelines (TG 403, 436, 412, 413), Pesticide Registration Standards (GB/T 15670), and New Chemical Substances Registration guidelines by the Ministry of Ecology and Environment.
Q: How is the safety of laboratory personnel ensured?
Safety is guaranteed using a negative pressure protection system and a double-core design in the exposure tower (positive pressure in the inner core and negative pressure in the outer core). Additionally, the system integrates seamlessly with a negative-pressure Fume Hood to prevent waste gases from escaping into the environment.
Q: What is the concentration uniformity of the Nose-Only Exposure Tower?
The uniformity and stability error of the mass concentration for each exposure port is within ±8% for gas, within ±10% for liquid aerosol, and within ±20% for dust aerosol, fully complying with OECD inhalation guidelines.
Q: What types of aerosol generators are compatible with this system?
The system supports multiple generators, including the Liquid Aerosol Generator (MMAD 1-3μm), the Dust Aerosol Generator (MMAD 1-4μm), Single-channel and Ten-channel Automatic Smoking Machines, and E-Cigarette Vape Generators.
Q: Does the host software support GLP laboratory requirements?
Yes, the host software is fully compliant with GLP standards. It includes essential features such as user classified management, audit trails, electronic signatures, and unerasable data recording.