Pathogenic Bioaerosol Infection System

Integrated with Class III BSC cabinet to ensure personnel and environment safety, the Pathogenic Bioaerosol Infection System is mainly used for research of viruses, bacteria and other biological aerosol or droplet infections between rodents and medium-sized animals. It can perform infection tests via direct contact, short-distance (5cm) droplet, and long-distance (1.5m) aerosol among rodents and medium-sized animals e.g., monkeys, guinea pigs, ferrets, rats, mice, etc. It also can be used to perform scientific tests such as transmitted infections modeling and mechanism studies.

    Features

    It can perform bioaerosol infection tests on rodents and medium-sized animals e.g., monkeys, guinea pigs, ferrets, rats, and mice.

    Three infection tests of direct contact transmission, droplet transmission and aerosol transmission can be performed.

    Meet long-term feeding requirements of laboratory animals.

    With rich functions of environmental monitoring and biosampling.

    With smart control software and system.

    For biosafety protective tightness requirements of Class III BSC cabinet working area, it conforms to RB/T 199-2015 Technical code for evaluating biosafety performance of laboratory equipment.

    Class III BSC cabinet adopts HEPA filtration for air inlet and double filtration for outlet. HEPA filter has a sterilization port and leakage detection port.

    The corner of Class III BSC cabinet adopts large arc design with sterilization port.

    Typical Users

    PLA Unit 32734

    National Institutes for Food and Drug Control

    Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences The First Affiliated Hospital of Nanchang University

    Chemical Defense Institute, Academy of Military Sciences, PLA

    WUHAN INSTITUTE OF BIOLOGICAL PRODUCTS CO.,LTD.

    PLA Army Chemical Defense College

    Military Veterinary Institute, Academy of Military Medical Sciences, Academy of Military Sciences, PLA

    Guangzhou Customs Technology Center

    The Fifth Medical Center of the PLA General Hospital

    Military Veterinary Institute, Academy of Military Medical Sciences, Academy of Military Sciences, PLA

    Application

    Studies of pathogenic bioaerosol infections

    Specification

    Applicable animals Monkeys, guinea pigs, ferrets, rats, mice (as requested)
    Droplet transmission distance 5cm
    Aerosol transmission distance 1.5m
    Number of animals in direct contact transmission group 4-5 guinea pigs (other animals can be customized)
    Number of animals in droplet transmission group 1-2 guinea pigs (other animals can be customized)
    Number of animals in aerosol transmission group 1-2 guinea pigs (other animals can be customized)
    Transmitted airflow 20-100L/min adjustable
    Bio-sampling flow 28.3L/min
    Environmental parameters monitoring Oxygen, carbon dioxide, ammonia, temp, humidity, etc.

    Standards

    RB∕T 199-2015 Technical code for evaluating biosafety performance of laboratory equipment

    GB 14925-2010 Laboratory animal-Requirements of environment and housing facilities